Research on pseudo-static cyclic tests of precast concrete shear walls with vertical rebar lapping in grout-filled constrained hole

被引:101
作者
Gu, Qian [1 ]
Dong, Ge [1 ]
Wang, Xiang [2 ]
Jiang, Hongbin [3 ]
Peng, Shaomin [1 ]
机构
[1] Wuhan Univ Technol, Sch Civil Engn & Architecture, Wuhan 430070, Hubei, Peoples R China
[2] Univ Paris 13, CNRS UPR 3407, Inst Galilee, Lab Sci Proc & Mat, F-93430 Villetaneuse, France
[3] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
关键词
Precast concrete shear wall; Horizontal assembly joint; Vertical rebar lap splice; Prepared grout-filled hole; Constraining spiral hoop; Cyclic test; Seismic behavior; SEISMIC PERFORMANCE; BEHAVIOR; SPLICE; DESIGN; CONNECTION; SLEEVE; STRENGTH; TENSILE; SYSTEMS;
D O I
10.1016/j.engstruct.2019.03.069
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the seismic behaviors of four precast shear wall specimens and one cast-in-place shear wall specimen are investigated by pseudo-static test method. For the precast shear wall specimens, a new type of assembled rebar lap splices with prepared grout-filled holes and constraining spiral hoops were applied. Different vertical rebar lap splice positions and different rebar lap lengths at the horizontal assembly joints of the precast specimens were designed and fabricated in order to compare their seismic behaviors with the cast-in-place specimen. The geometric size and rebars of four precast specimens are totally same as those of the cast-in-place specimen. By analysis of test results including the load-lateral drift hysteresis curves, crack propagation and rebar strains, the failure modes, bearing capacity, hysteretic characteristics, ductility, rigidity degeneration and energy dissipation of all specimens were obtained and compared. The test results show that the precast concrete shear walls with horizontal assembly joints by this kind of rebar connection have good seismic behaviors and could be equivalent to the cast-in-place shear walls on the conditions of specified construction details.
引用
收藏
页码:396 / 410
页数:15
相关论文
共 48 条
[1]   A simplified analysis method for characterizing unbonded post-tensioned precast wall systems [J].
Aaleti, Sriram ;
Sritharan, Sri .
ENGINEERING STRUCTURES, 2009, 31 (12) :2966-2975
[2]  
[Anonymous], 1966, P 2 JAP EARTHQ ENG S
[3]  
[Anonymous], 2003, JGJT1012015
[4]  
Belleri A., 2017, PCI J, V57, P97
[5]   Development of a precast concrete shear-wall system requiring special code acceptance [J].
Bora, Can ;
Oliva, Michael G. ;
Nakaki, Suzanne Dow ;
Becker, Roger .
PCI JOURNAL, 2007, 52 (01) :122-+
[6]  
Einea A., 1995, PCI J., V40, P82
[7]   Self-Centering Behavior of Unbonded, Post-Tensioned Precast Concrete Shear Walls [J].
Erkmen, Bulent ;
Schultz, Arturo E. .
JOURNAL OF EARTHQUAKE ENGINEERING, 2009, 13 (07) :1047-1064
[8]   Damage avoidance design for buildings [J].
Hamid, N. H. ;
Mander, John B. .
KSCE JOURNAL OF CIVIL ENGINEERING, 2014, 18 (02) :541-548
[9]   A Comparative Seismic Performance Between Precast Hollow Core Walls and Conventional Walls Using Incremental Dynamic Analysis [J].
Hamid, N. H. ;
Mander, John B. .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (07) :1801-1815
[10]   Lateral Seismic Performance of Multipanel Precast Hollowcore Walls [J].
Hamid, N. H. ;
Mander, John B. .
JOURNAL OF STRUCTURAL ENGINEERING, 2010, 136 (07) :795-804