Quantitative impact of cardiovascular risk factors and vascular closure devices on the femoral artery after repeat cardiac catheterization

被引:5
作者
Tiroch, Klaus A. [1 ,2 ]
Matheny, Michael E. [3 ,4 ]
Resnic, Frederic S. [1 ]
机构
[1] Brigham & Womens Hosp, Dept Cardiovasc Med, Boston, MA 02115 USA
[2] Deutsch Herzzentrum Munich, Munich, Germany
[3] Vet Hlth Adm, Nashville, TN USA
[4] Vanderbilt Univ, Nashville, TN USA
关键词
PERCUTANEOUS CORONARY INTERVENTION; MANUAL COMPRESSION; COMPLICATIONS; METAANALYSIS; PREDICTORS;
D O I
10.1016/j.ahj.2009.10.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background We evaluated the exact quantitative long-term impact of repeated catheterizations, vascular closure devices, and cardiovascular risk factors on the femoral artery after cardiac catheterization. Methods A total of 2,102 available femoral angiograms from 827 consecutive patients were analyzed using caliper-based quantitative vascular analysis. These patients underwent coronary interventions between January 2005 and April 2007 and had at least one additional catheterization procedure through the ipsilateral femoral access site from December 2001 until January 2008. Multivariate analysis was performed to control for confounding variables. The primary outcome was change in artery size. Results The average punctured artery diameter was 6.5 +/- 2.1 mm. The average time between the first case and last follow-up was 349 days. There was no significant change of the punctured artery size over time after the index procedure (P = .15) and no change associated with the use of vascular closure devices (P = .25) after multivariate analysis. Smaller arteries were associated with female gender (-1.22 mm, P < .0001), presence of angiographic peripheral vascular disease (PVD, -1.19 mm, P < .0001), and current (-0.48 mm, P = .001) or former (-0.23 mm, P = .01) smoking status, whereas previous statin therapy was associated with an increase in artery size (+0.47 mm, P < .0001). Vascular closure devices were used less often compared with manual compression in cases preceding the first detection of angiographic PVD (P < .001). Conclusion Vascular closure devices are not associated with a change in the artery size or progression of PVD. Overall, there is no change in vessel size over time after repeat catheterizations, with a decrease in vessel size associated with current and former smoking and an increase with previous statin therapy. (Am Heart J 2010; 159: 125-30.)
引用
收藏
页码:125 / 130
页数:6
相关论文
共 50 条
  • [21] Complications with Angio-Seal™ Vascular Closure Devices Compared with Manual Compression after Diagnostic Cardiac Catheterization and Percutaneous Coronary Intervention
    Gregory, Deborah
    Midodzi, William
    Pearce, Neil
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2013, 26 (06) : 630 - 638
  • [22] Long Term Clinical Outcomes After Deployment of Femoral Vascular Closure Devices in Coronary Angiography and Percutaneous Coronary Intervention
    Lee, Stephen Wai-Luen
    Ho, Hee-Hwa
    Kong, Shun-Ling
    Lam, Yui-Ming
    Siu, Chung-Wah
    Miu, Kin-Man
    Lam, Linda
    Chan, Hon-Wah
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (03) : 345 - 348
  • [23] Combining Percutaneous Ultrasound-Guided Hematoma Aspiration and Compression Repair to Treat Femoral Artery Pseudoaneurysm after Cardiac Catheterization
    Chen, Gang
    Wu, Lingmin
    Zheng, Lihui
    Ding, Ligang
    Wong, Tom
    Zhang, Shu
    Yao, Yan
    INTERNATIONAL HEART JOURNAL, 2018, 59 (02) : 333 - 338
  • [24] Risk Factors for Infectious Complications with Angio-Seal Percutaneous Vascular Closure Devices
    Franco, Johnny
    Motaganahalli, Raghunandan
    Habeeb, Murtz
    Wittgen, Catherine
    Peterson, Gary
    VASCULAR, 2009, 17 (04) : 218 - 221
  • [25] Impact of Conventional Cardiovascular Risk Factors on Left Internal Mammary Artery Graft Disease
    Zuo, Hui-Juan
    Nan, Nan
    Yang, Hong-Xia
    Wang, Jin-Wen
    Song, Xian-Tao
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [26] Endovascular repair of a common femoral artery puncture after losing access using a vascular closure device
    Reddy, Vamsi
    Todnem, Nathan
    Franco-Mesa, Camila
    Erben, Young
    Tawk, Rabih G.
    Ritchie, Charles
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2021, 7 (03): : 466 - 468
  • [27] INCIDENCE RATE OF ANEURYSMA SPURIUM OF THE FEMORAL-ARTERY AFTER CARDIAC-CATHETERIZATION AND PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY
    MOLL, R
    HABSCHEID, W
    LANDWEHR, P
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (01): : 23 - 27
  • [28] Clinical and Subclinical Femoral Vascular Complications after Deployment of two Different Vascular Closure Devices or Manual Compression in the Setting of Coronary Intervention
    Yeni, Hakan
    Axel, Meissner
    Oernek, Ahmet
    Butz, Thomas
    Maagh, Petra
    Plehn, Gunnar
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2016, 13 (04): : 255 - 259
  • [29] Risk Factors Affecting Complications of Access Site in Vascular Intervention through Common Femoral Artery
    Lee, M. O.
    Jeong, K. U.
    Kim, K. M.
    Song, Y. G.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2022, 25 (01) : 85 - 89
  • [30] The Use of Vascular Closure Devices Outside the Catheterization Laboratory After Neurointerventional Procedures Is Safe and Effective: Evidence From a Retrospective Study
    Khatri, Rakesh
    Rostambeigi, Nassir
    Hassan, Ameer E.
    Carlson, Blake
    Rodriguez, Gustavo J.
    Qureshi, Adnan I.
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (02) : 239 - 245