Development of a shear testing method for full-sized structural lumber

被引:3
|
作者
Morita, Hideki [1 ]
Fujimoto, Yoshiyasu
Komatsu, Kohei
Murase, Yasuhide
机构
[1] Miyazaki Prefectural Wood Utilizat Res Ctr, Miyakonojo 8850037, Japan
[2] Res Inst Sustainable Humanosphere, Uji 6110011, Japan
[3] Kyushu Univ, Fac Agr, Fukuoka 8128581, Japan
来源
MOKUZAI GAKKAISHI | 2006年 / 52卷 / 06期
关键词
shear strength; testing method; full-sized structural lumber; sugi;
D O I
10.2488/jwrs.52.376
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
An asymmetric four-point-bending type shear test was developed to evaluate the shear strength of full-sized structural lumber. Medium dimension glulam made of sugi (Cryptomeria japonica D. Don) from Miyazaki prefecture was tested to confirm applicability of this testing method. Results obtained are summarized as follows: 1) It was found that partial compressive deformation at loading points prevented full-sized structural lumber from shear fracture when the shear strength of sugi specimens with low density grown in Miyazaki prefecture was evaluated by the three-point-bending type shear test. 2) Every glulam specimen tested by the asymmetric four-point-bending type shear test fractured neither by bending stress nor by partial compressive stress perpendicular to grain, but by shear stress. It was confirmed that using saddle-type steel jigs attached with lag screws was very effective in inhibiting partial compressive deformation at loading and supporting points. 3) The necessary number of lag screws could be estimated from the expression including shear stress, bending stress and partial compressive stress perpendicular to grain at loading and supporting points. 4) The average shear strength of medium dimension sugi glulam was 8.0 N/mm(2). This value was larger than the one obtained by the three-point-bending type shear test.
引用
收藏
页码:376 / 382
页数:7
相关论文
共 50 条
  • [1] EFFECT OF DECAY ON THE MECHANICAL-PROPERTIES OF FULL-SIZED LUMBER
    KIM, GH
    BARNES, HM
    LYON, DE
    HOLZFORSCHUNG, 1994, 48 (02) : 145 - 149
  • [2] Programmed fatigue test for full-sized structural components
    Anon
    Gongcheng jixie, 1988, 19 (07): : 17 - 21
  • [3] Full-sized visualization center
    不详
    JOURNAL OF PETROLEUM TECHNOLOGY, 2000, 52 (05): : 18 - 18
  • [4] Full-sized car segment
    Automotive Industries, 1991, 171 (10):
  • [5] DEVELOPMENT OF AN OMNIDIRECTIONAL WALKING ENGINE FOR FULL-SIZED LIGHTWEIGHT HUMANOID ROBOTS
    Song, Seungmoon
    Ryoo, Young-Jae
    Hong, Dennis W.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE - 2011, VOL 6, PTS A AND B, 2012, : 847 - +
  • [6] Effect of asymmetric shear wall layouts on full-sized Japanese wooden house construction
    Tsuchimoto, T
    Arima, T
    Hirano, S
    Furusawa, S
    Suzuki, K
    Nishiyama, N
    5TH WORLD CONFERENCE ON TIMBER ENGINEERING, VOL 1, PROCEEDINGS, 1998, : 388 - 395
  • [7] Midsize applicator packs full-sized punch
    Anon
    Machine Design, 2001, 73 (23)
  • [8] Flexural Properties of Full-Sized Bongossi Wood
    Komatsu, Kohei
    Horie, Kazumi
    Hwang, Kweon-Hwan
    Mokuzai Gakkaishi/Journal of the Japan Wood Research Society, 44 (05): : 368 - 374
  • [9] Flexural properties of full-sized bongossi wood
    Komatsu, K
    Horie, K
    Hwang, KH
    MOKUZAI GAKKAISHI, 1998, 44 (05): : 368 - 374
  • [10] PERINATAL DEATH OF FULL-SIZED AND FULL-TERM INFANTS
    GRUENWALD, P
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1970, 107 (07) : 1022 - +