An integral quality monitoring system for real-time verification of intensity modulated radiation therapy

被引:69
作者
Islam, Mohammad K. [1 ,2 ,3 ]
Norrlinger, Bernhard D. [1 ]
Smale, Jason R. [1 ]
Heaton, Robert K. [1 ,2 ]
Galbraith, Duncan [1 ]
Fan, Cary [3 ]
Jaffray, David A. [1 ,2 ,4 ]
机构
[1] Princess Margaret Hosp, Radiat Med Program, Dept Radiat Phys, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
[3] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 2Z9, Canada
[4] Univ Toronto, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
IMRT; real-time quality assurance; on-line treatment verification; IGART; large area ionization chamber; FLAT-PANEL; SCATTER; RADIOTHERAPY; DELIVERY; PROSTATE; FILTERS; IMAGER; FIELDS; OUTPUT; IMRT;
D O I
10.1118/1.3250859
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop an independent and on-line beam monitoring system, which can validate the accuracy of segment-by-segment energy fluence delivery for each treatment field. The system is also intended to be utilized for pretreatment dosimetric quality assurance of intensity modulated radiation therapy (IMRT), on-line image-guided adaptive radiation therapy, and volumetric modulated arc therapy. Methods: The system, referred to as the integral quality monitor (IQM), utilizes an area integrating energy fluence monitoring sensor (AIMS) positioned between the final beam shaping device [i.e., multileaf collimator (MLC)] and the patient. The prototype AIMS consists of a novel spatially sensitive large area ionization chamber with a gradient along the direction of the MLC motion. The signal from the AIMS provides a simple output for each beam segment, which is compared in real time to the expected value. The prototype ionization chamber, with a physical area of 22 x 22 cm(2), has been constructed out of aluminum with the electrode separations varying linearly from 2 to 20 mm. A calculation method has been developed to predict AIMS signals based on an elementwise integration technique, which takes into account various predetermined factors, including the spatial response function of the chamber, MLC characteristics, beam transmission through the secondary jaws, and field size factors. The influence of the ionization chamber on the beam has been evaluated in terms of transmission, surface dose, beam profiles, and depth dose. The sensitivity of the system was tested by introducing small deviations in leaf positions. A small set of IMRT fields for prostate and head and neck plans was used to evaluate the system. The ionization chamber and the data acquisition software systems were interfaced to two different types of linear accelerators: Elekta Synergy and Varian iX. Results: For a 10 x 10 cm(2) field, the chamber attenuates the beam intensity by 7% and 5% for 6 and 18 MV beams, respectively, without significantly changing the depth dose, surface dose, and dose profile characteristics. An MLC bank calibration error of 1 mm causes the IQM signal of a 3 x 3 cm(2) aperture to change by 3%. A positioning error in a single 5 mm wide leaf by 3 mm in 3 x 3 cm(2) aperture causes a signal difference of 2%. Initial results for prostate and head and neck IMRT fields show an average agreement between calculation and measurement to within 1%, with a maximum deviation for each of the smallest beam segments to within 5%. When the beam segments of a prostate IMRT field were shifted by 3 mm from their original position, along the direction of the MLC motion, the IQM signals varied, on average, by 2.5%. Conclusions: The prototype IQM system can validate the accuracy of beam delivery in real time by comparing precalculated and measured AIMS signals. The system is capable of capturing errors in MLC leaf calibration or malfunctions in the positioning of an individual leaf. The AIMS does not significantly alter the beam quality and therefore could be implemented without requiring recommissioning measurements. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3250859]
引用
收藏
页码:5420 / 5428
页数:9
相关论文
共 16 条
[1]   ANALYTIC MODELING OF PHOTON SCATTER FROM FLATTENING FILTERS IN PHOTON THERAPY BEAMS [J].
AHNESJO, A .
MEDICAL PHYSICS, 1994, 21 (08) :1227-1235
[2]   Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager [J].
Antonuk, LE ;
Yorkston, J ;
Huang, WD ;
Sandler, H ;
Siewerdsen, JH ;
ElMohri, Y .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03) :661-672
[3]   Intensity-modulated radiation therapy with dynamic multileaf collimators [J].
Boyer, AL ;
Yu, CX .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :48-59
[4]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[5]  
Ezzell G A, 2001, J Appl Clin Med Phys, V2, P138, DOI 10.1120/1.1386508
[6]   Cone-beam computed tomography with a flat-panel imager: Initial performance characterization [J].
Jaffray, DA ;
Siewerdsen, JH .
MEDICAL PHYSICS, 2000, 27 (06) :1311-1323
[7]   A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery [J].
Jursinic, PA ;
Nelms, BE .
MEDICAL PHYSICS, 2003, 30 (05) :870-879
[8]   An equivalent square field formula for determining head scatter factors of rectangular fields [J].
Kim, S ;
Zhu, TC ;
Palta, JR .
MEDICAL PHYSICS, 1997, 24 (11) :1770-1774
[9]   A generalized solution for the calculation of in-air output factors in irregular fields [J].
Kim, SY ;
Palta, JR ;
Zhu, TC .
MEDICAL PHYSICS, 1998, 25 (09) :1692-1701
[10]   A widely tested model for head scatter influence on photon beam output [J].
Olofsson, J ;
Georg, D ;
Karlsson, M .
RADIOTHERAPY AND ONCOLOGY, 2003, 67 (02) :225-238