Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel-Titanium Stent: Feasibility and Safety Porcine Trial

被引:26
作者
Ahlhelm, Frank [1 ]
Kaufmann, Ralf [1 ]
Ahlhelm, Dirk
Ong, Mai Fang
Roth, Christian [1 ]
Reith, Wolfgang [1 ]
机构
[1] Univ Saarland, Clin Diagnost & Intervent Neuroradiol, Sch Med, D-66421 Homburg, Germany
关键词
Interventional radiology; Animal study; Stenting; HIGH-RISK PATIENTS; CORONARY-ARTERIES; NEOINTIMAL HYPERPLASIA; NITINOL STENT; PLACEMENT; RESTENOSIS; STENOSIS; ENDARTERECTOMY; ANGIOPLASTY; HEPARIN;
D O I
10.1007/s00270-009-9572-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel-titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular intervention as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted.
引用
收藏
页码:1019 / 1027
页数:9
相关论文
共 28 条
  • [21] In vivo evaluation of a biolimus eluting nickel titanium self expanding stent with overlapping balloon expandable drug eluting and bare metal stents in a porcine coronary model
    Cilingiroglu, Mehmet
    Elliott, James
    Sangi, Pramod
    Matthews, Holly
    Tio, Fermin
    Trauthen, Brett
    Elicker, John
    Bailey, Steven R.
    EUROINTERVENTION, 2009, 4 (04) : 534 - 541
  • [22] Long-term effects of novel biolimus eluting DEVAX AXXESS plus nitinol self-expanding stent in a porcine coronary model
    Cilingiroglu, Mehmet
    Elliott, Jim
    Patel, Devang
    Tio, Furman
    Matthews, Holly
    McCasland, Melissa
    Trauthen, Brett
    Elicker, John
    Bailey, Steven R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (02) : 271 - 279
  • [23] Serial Intravascular Ultrasound Analysis of Bifurcation Lesions Treated Using the Novel Self-Expanding Sideguard Side Branch Stent
    Doi, Hiroshi
    Maehara, Akiko
    Mintz, Gary S.
    Dani, Lokesh
    Leon, Martin B.
    Grube, Eberhard
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (09) : 1216 - 1221
  • [24] Endovascular treatment of femoro-popliteal artery stenosis/obstruction using a repositionable self-expanding nitinol stent: a preliminary study
    Yilmaz, Seyhan
    Yilmaz, Behice Kaniye
    Baris, Ozgur
    Findik, Orhan
    Kalender, Mehmet
    Aksoy, Eray
    ACTA ANGIOLOGICA, 2015, 21 (04): : 116 - 121
  • [25] Self-Expanding Nitinol Renal Artery Stents: Comparison of Safety and Efficacy of Bare Versus Polyzene-F Nanocoated Stents in a Porcine Model
    P. Kurz
    U. Stampfl
    P. Christoph
    C. Henn
    S. Satzl
    B. Radeleff
    I. Berger
    G. M. Richter
    CardioVascular and Interventional Radiology, 2011, 34 : 139 - 148
  • [26] Efficacy and safety of a novel multisegmented fully covered self-expanding metal stent for malignant esophageal obstruction: a prospective pilot study with historical control
    Noh, Jin Hee
    Gong, Eun Jeong
    Kim, Do Hoon
    Na, Hee Kyong
    Ahn, Ji Yong
    Lee, Jeong Hoon
    Jung, Kee Wook
    Choi, Kee Don
    Song, Ho June
    Lee, Gin Hyug
    Jung, Hwoon-Yong
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2025, 39 (02): : 942 - 951
  • [27] Transradial carotid artery stenting using double layer micromesh stent and novel post-dilation balloon with integrated embolic protection
    Petkoska, Danica
    Zafirovska, Biljana
    Vasilev, Ivan
    Saylors, Elizabeth
    Sachar, Ravish
    Kedev, Sasko
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 63 : 43 - 51
  • [28] Analysis of Left Main Coronary Artery Bifurcation Lesions Treated With Biolimus-Eluting DEVAX AXXESS Plus Nitinol Self-Expanding Stent: Intravascular Ultrasound Results of the AXXENT Trial
    Hasegawa, Takao
    Ako, Junya
    Koo, Bon-Kwon
    Miyazawa, Akiyoshi
    Sakurai, Ryota
    Chang, Hyeonsoo
    Dens, Joseph
    Verheye, Stefan
    Grube, Eberhard
    Honda, Yasuhiro
    Fitzgerald, Peter J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (01) : 34 - 41