Osseointegration on metallic implant surfaces: Effects of microgeometry and growth factor treatment

被引:70
作者
Frenkel, SR
Simon, J
Alexander, H
Dennis, M
Ricci, JL
机构
[1] NYU, Hosp Joint Dis, Musculoskeletal Res Ctr, Dept Orthopaed Surg, New York, NY 10003 USA
[2] Orthogen Inc, Springfield, NJ USA
[3] Univ Med & Dent New Jersey, Newark, NJ 07103 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2002年 / 63卷 / 06期
关键词
joint prosthesis; implant loosening; growth factor; textured surface; animal model;
D O I
10.1002/jbm.10408
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Orthopedic implants often loosen due to the invasion of fibrous tissue. The aim of this study was to devise a novel implant surface that would speed healing adjacent to the surface, and create a stable interface for bone integration, by using a chemoattractant for bone precursor cells, and by controlling tissue migration at implant surfaces via specific surface microgeometry design. Experimental surfaces were tested in a canine implantable chamber that simulates the intramedullary bone response around total joint implants. Titanium and alloy surfaces were prepared with specific microgeometries, designed to optimize tissue attachment and control fibrous encapsulation. TGFbeta, a mitogen and chemoattractant (Hunziker EB, Rosenberg LC. J Bone Joint Surg Am 1996;78:721-733) for osteoprogenitor cells, was used to recruit progenitor cells to the implant surface and to enhance their proliferation. Calcium sulfate hemihydrate (CS) was the delivery vehicle for TGFbeta; CS resorbs rapidly and appears to be osteoconductive. Animals were sacrificed at 6 and 12 weeks postoperatively. Results indicated that TGFbeta can be reliably released in an active form from a calcium sulfate carrier in vivo. The growth factor had a significant effect on bone ingrowth into implant channels at an early time period, although this effect was not seen with higher doses at later periods. Adjustment of dosage should render TGFbeta more potent at later time periods. Calcium sulfate treatment without TGFbeta resulted in a significant increase in bone ingrowth throughout the 12-week time period studied. Bone response to the microgrooved surfaces was dramatic, causing greater ingrowth in 9 of the 12 experimental conditions. Microgrooves also enhanced the mechanical strength of CS-coated specimens. The grooved surface was able to control the direction of ingrowth. This surface treatment may result in a clinically valuable implant design to induce rapid ingrowth and a strong bone-implant interface, contributing to implant longevity. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:706 / 713
页数:8
相关论文
共 36 条
  • [1] Al Ruhaimi KA, 2000, INT J ORAL MAX IMPL, V15, P859
  • [2] Alexander DI, 2001, CAN J SURG, V44, P262
  • [3] ASHHURST DE, 1994, T ORTHOP RES SOC, V19, P324
  • [4] Basic N, 1996, J BONE MINER RES, V11, P384
  • [5] Brunette D M, 1988, Int J Oral Maxillofac Implants, V3, P231
  • [6] OSSEOINTEGRATION OF TITANIUM IMPLANTS
    CARLSSON, L
    ROSTLUND, T
    ALBREKTSSON, B
    ALBREKTSSON, T
    BRANEMARK, PI
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (04): : 285 - 289
  • [7] CENTRELLA M, 1987, J BIOL CHEM, V262, P2869
  • [8] EFFECTS OF A GROOVED TITANIUM-COATED IMPLANT SURFACE ON EPITHELIAL-CELL BEHAVIOR INVITRO AND INVIVO
    CHEHROUDI, B
    GOULD, TRL
    BRUNETTE, DM
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (09): : 1067 - 1085
  • [9] Choueka J, 1996, J BIOMED MATER RES, V31, P35, DOI 10.1002/(SICI)1097-4636(199605)31:1<35::AID-JBM5>3.0.CO
  • [10] 2-R