Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur Fractures

被引:68
|
作者
Otto, Randall J. [1 ]
Moed, Berton R. [1 ]
Bledsoe, J. Gary [2 ]
机构
[1] St Louis Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO 63110 USA
[2] St Louis Univ, Pk Coll Engn Aviat & Technol, Dept Biomed Engn, St Louis, MO 63110 USA
关键词
polyaxial; distal femur; locking plate; fracture fixation; biomechanics; INVASIVE STABILIZATION SYSTEM; BLADE PLATE; SCREW;
D O I
10.1097/BOT.0b013e3181a567c8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To test the stability to axial loading of 2 new polyaxial locking screw-plate designs and analyze different angles of screw insertion. The noncontact bridging (NCB) polyaxial locking plate (Zimmer) and the POLYAX plate (DePuy) were compared with a fixed-angle less invasive stabilization system (LISS; Synthes). Methods: Twenty-five synthetic femurs were divided into 5 groups and assigned fixation with the LISS plate (group I), POLYAX plate (groups IIA and IIB), or NCB plate (groups IIIA and IIIB). The polyaxial constructs were divided into parallel and crossed distal condylar screw configurations. Each construct was tested under axial loading and stressed to failure at a displacement rate of 5 mm/min with a preload of 100 N. Outcome measurements included stiffness, load to failure, peak force, and mode of failure, Results: All LISS and POLYAX constructs failed by plastic deformation of the plate, whereas 9 of 10 NCB constructs failed by an intraarticular lateral condyle fracture. No failures occurred at the screwplate interface in either polyaxial constructs. Load to failure of the LISS was 33% greater than the parallel POLYAX (P < 0.01) and 24% greater than the crossed POLYAX (P < 0.01). Load to failure of NCB (parallel and crossed) were 24% greater than the parallel POLYAX (P < 0.01 and P < 0.01, respectively) and 1501,, greater than the crossed POLYAX (P < 0.01 and P = 0.02, respectively). The POLYAX also had significantly lower stiffness and peak force compared with the LISS and NCB. There was no difference between the LISS and NCB with regard to stiffness, load to failure, and peak force. Parallel and crossed polyaxial constructs showed no difference in stiffness or failure loads. Conclusions: There were no failures of either polyaxial screw-plate interface despite large forces and screw angle did not affect the overall strength of these constructs, supporting the biomechanical soundness of both polyaxial device designs under axial loading. However, the POLYAX supported smaller loads compared with the LISS and NCB while under axial loading. In addition, the mode of failure of the NCB plate, creating an intra-articular fracture propagating from the distal posterior screw hole, may be of some concern. Additional testing is needed to determine the clinical importance of the demonstrated differences among these plate designs.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 50 条
  • [41] Biomechanical comparison of two locking plate systems for the distal tibia
    F. Högel
    S. Hoffmann
    P. Weninger
    V. Bühren
    P. Augat
    European Journal of Trauma and Emergency Surgery, 2012, 38 : 53 - 58
  • [42] A Biomechanical Comparison of a Locking Plate, a Nail, and a 95° Angled Blade Plate for Fixation of Subtrochanteric Femoral Fractures
    Forward, Daren P.
    Doro, Christopher J.
    O'Toole, Robert V.
    Kim, Hyunchul
    Floyd, John C. P.
    Sciadini, Marcus F.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (06) : 334 - 340
  • [43] Biomechanical comparison of two locking plate systems for the distal tibia
    Hoegel, F.
    Hoffmann, S.
    Weninger, P.
    Buehren, V.
    Augat, P.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2012, 38 (01) : 53 - 58
  • [44] Polyaxial locking plates in treating distal humeral fractures: a comparative randomized trial for clinical outcome
    Moritz Crönlein
    Martin Lucke
    Marc Beirer
    Dominik Pförringer
    Chlodwig Kirchhoff
    Peter Biberthaler
    Karl F. Braun
    Sebastian Siebenlist
    BMC Musculoskeletal Disorders, 18
  • [45] Polyaxial locking plates in treating distal humeral fractures: a comparative randomized trial for clinical outcome
    Croenlein, Moritz
    Lucke, Martin
    Beirer, Marc
    Pfoerringer, Dominik
    Kirchhoff, Chlodwig
    Biberthaler, Peter
    Braun, Karl F.
    Siebenlist, Sebastian
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [46] Complex Distal Humerus Fractures-Comparison of Polyaxial Locking and Nonlocking Screw Configurations-A Preliminary Biomechanical Study
    Hungerer, Sven
    Wipf, Felix
    von Oldenburg, Geert
    Augat, Peter
    Penzkofer, Rainer
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (03) : 130 - 136
  • [47] Minimally-invasive fixation of distal extra-articular femur fractures with locking plates: Limitations and failures
    Ehlinger, M.
    Adam, P.
    Arlettaz, Y.
    Moor, B. K.
    DiMarco, A.
    Brinkert, D.
    Bonnomet, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (06) : 668 - 674
  • [48] Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures
    Midtgaard, Kaare Sourin
    Soreide, Endre
    Brattgjerd, Jan Egil
    Moatshe, Gilbert
    Madsen, Jan Erik
    Flugsrud, Gunnar B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (06) : 1242 - 1248
  • [49] Radiographic Healing of Far Cortical Locking Constructs in Distal Femur Fractures: A Comparative Study With Standard Locking Plates
    Plumarom, Yanin
    Wilkinson, Brandon G.
    Marsh, J. Lawrence
    Willey, Michael C.
    An, Qiang
    Gao, Yubo
    Karam, Matthew D.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (06) : 277 - 283
  • [50] Comparison of Locking Versus Nonlocking Plates for Distal Fibula Fractures
    Lyle, Shirley A.
    Malik, Catherine
    Oddy, Michael J.
    JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (04) : 664 - 667