Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur Fractures

被引:68
|
作者
Otto, Randall J. [1 ]
Moed, Berton R. [1 ]
Bledsoe, J. Gary [2 ]
机构
[1] St Louis Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO 63110 USA
[2] St Louis Univ, Pk Coll Engn Aviat & Technol, Dept Biomed Engn, St Louis, MO 63110 USA
关键词
polyaxial; distal femur; locking plate; fracture fixation; biomechanics; INVASIVE STABILIZATION SYSTEM; BLADE PLATE; SCREW;
D O I
10.1097/BOT.0b013e3181a567c8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To test the stability to axial loading of 2 new polyaxial locking screw-plate designs and analyze different angles of screw insertion. The noncontact bridging (NCB) polyaxial locking plate (Zimmer) and the POLYAX plate (DePuy) were compared with a fixed-angle less invasive stabilization system (LISS; Synthes). Methods: Twenty-five synthetic femurs were divided into 5 groups and assigned fixation with the LISS plate (group I), POLYAX plate (groups IIA and IIB), or NCB plate (groups IIIA and IIIB). The polyaxial constructs were divided into parallel and crossed distal condylar screw configurations. Each construct was tested under axial loading and stressed to failure at a displacement rate of 5 mm/min with a preload of 100 N. Outcome measurements included stiffness, load to failure, peak force, and mode of failure, Results: All LISS and POLYAX constructs failed by plastic deformation of the plate, whereas 9 of 10 NCB constructs failed by an intraarticular lateral condyle fracture. No failures occurred at the screwplate interface in either polyaxial constructs. Load to failure of the LISS was 33% greater than the parallel POLYAX (P < 0.01) and 24% greater than the crossed POLYAX (P < 0.01). Load to failure of NCB (parallel and crossed) were 24% greater than the parallel POLYAX (P < 0.01 and P < 0.01, respectively) and 1501,, greater than the crossed POLYAX (P < 0.01 and P = 0.02, respectively). The POLYAX also had significantly lower stiffness and peak force compared with the LISS and NCB. There was no difference between the LISS and NCB with regard to stiffness, load to failure, and peak force. Parallel and crossed polyaxial constructs showed no difference in stiffness or failure loads. Conclusions: There were no failures of either polyaxial screw-plate interface despite large forces and screw angle did not affect the overall strength of these constructs, supporting the biomechanical soundness of both polyaxial device designs under axial loading. However, the POLYAX supported smaller loads compared with the LISS and NCB while under axial loading. In addition, the mode of failure of the NCB plate, creating an intra-articular fracture propagating from the distal posterior screw hole, may be of some concern. Additional testing is needed to determine the clinical importance of the demonstrated differences among these plate designs.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 50 条
  • [21] Severity of Complications after Locking Plate Osteosynthesis in Distal Femur Fractures
    Gurung, Roshan
    Terrill, Alexander
    White, Gentry
    Windolf, Markus
    Hofmann-Fliri, Ladina
    Dlaska, Constantin
    Schuetz, Michael
    Epari, Devakara R.
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [22] Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers
    Blythe, Murray
    Stoffel, Karl
    Jarrett, Paul
    Kuster, Markus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (10): : 1587 - 1593
  • [23] Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures?
    Kim, Beom-Soo
    Kim, Du-Han
    Choi, Jung-Hoon
    Choi, Byung-Chan
    Cho, Chul-Hyun
    MEDICINA-LITHUANIA, 2022, 58 (03):
  • [24] Biomechanical Assessment of Locking Plate Fixation of Comminuted Proximal Olecranon Fractures
    Fantry, Amanda
    Sobel, Andrew
    Capito, Nicholas
    Hodax, Jonathan D.
    Pidgeon, Tyler
    Koruprolu, Sarath
    Rich, Ryan
    Fava, Joseph L.
    Green, Andrew
    Paxton, Scott
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (11) : E445 - E450
  • [25] Increased stiffness with medial column screw supplementation of lateral locking plate for distal femur fractures: a biomechanical study
    Henningsen, Joseph
    Mobley, Kyle
    Huff, Scott
    Perrin, Joshua
    Naylor, William
    Froehle, Andrew
    Jerele, Jennifer
    Prayson, Michael
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [26] Biomechanical Comparison of Fixed- versus Variable-Angle Locking Screws for Distal Humerus Comminuted Fractures
    Nourbakhsh, Ali
    Hirschfeld, Adam G.
    Dhulipala, Sravan
    Hutton, William
    Ganey, Timothy
    Lozada, Luis
    Schlatterer, Daniel
    Lourie, Gary Mark
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (03) : 302 - 308
  • [27] Biomechanical Comparison of 2 Different Locking Plate Fixation Methods in Vancouver B1 Periprosthetic Femur Fractures
    Pletka, Joshua D.
    Marsland, Daniel
    Belkoff, Stephen M.
    Mears, Simon C.
    Kates, Stephen L.
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2011, 2 (02) : 51 - 55
  • [28] Treatment of Distal Femur Nonunion Following Initial Fixation with a Lateral Locking Plate
    Ebraheim, Nabil A.
    Buchanan, Grant S.
    Liu, Xiaochen
    Cooper, Maxwell E.
    Peters, Nicholas
    Hessey, Jacob A.
    Liu, Jiayong
    ORTHOPAEDIC SURGERY, 2016, 8 (03) : 323 - 330
  • [29] Arthroplasty compared to internal fixation by locking plate osteosynthesis in comminuted fractures of the distal humerus
    Ellwein, Alexander
    Lill, Helmut
    Voigt, Christine
    Wirtz, Pauline
    Jensen, Gunnar
    Katthagen, Jan Christoph
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (04) : 747 - 754
  • [30] Arthroplasty compared to internal fixation by locking plate osteosynthesis in comminuted fractures of the distal humerus
    Alexander Ellwein
    Helmut Lill
    Christine Voigt
    Pauline Wirtz
    Gunnar Jensen
    Jan Christoph Katthagen
    International Orthopaedics, 2015, 39 : 747 - 754