Volumetric monochromatic x-ray tomography of the lungs

被引:1
|
作者
Paschal, CB [1 ]
Carroll, FE [1 ]
Worrell, JA [1 ]
Mendenhall, MH [1 ]
Traeger, R [1 ]
Waters, JW [1 ]
Brzymialkiewicz, CN [1 ]
Banks, GA [1 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
来源
BIOMEDICAL APPLICATIONS OF FREE-ELECTRON LASERS | 2000年 / 3925卷
关键词
monochromatic; x-ray; imaging; tomography; three-dimensional; pulmonary; lungs;
D O I
10.1117/12.384251
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monochromatic x-rays were produced by inverse Compton scattering resulting from counter-propagation of a tunable free electron laser electron beam and its own infrared photon beam In a manner analogous to electron beam CT, a mechanism was developed here for obtaining multiple projection views with monochromatic x-rays by deflecting x-rays off of mosaic crystals mounted on rotating stages. These crystals are both energy and angle selective. X-rays are detected digitally when they strike a phosphorescent screen mounted in front of a CCD camera. Using this system, multiple projection images of a three-dimensional (3D) phantom and of rat lungs ex vivo were obtained. In an alternate micro-CT arrangement, rat lungs in situ were imaged by rotating the rat in front of both a polychromatic beam from a molybdenum target x-ray tube and the same beam monochromatized with a mosaic crystal. In the first arrangement, depth information was revealed by relative position changes of features seen in each projection and the similar to 0.16 mm thick walls of a catheter were visible in the images. Using conventional tomography, the projections were reconstructed into slice images. Overall, these monochromatic x-ray imaging methods offer reduced x-ray dose, the potential for improved contrast resolution, and now 3D information.
引用
收藏
页码:2 / 7
页数:6
相关论文
共 50 条
  • [31] The experimental application of X-ray tomography to a vapor-liquid contactor
    Schmit, CE
    Cartmel, DB
    Eldridge, RB
    CHEMICAL ENGINEERING SCIENCE, 2001, 56 (11) : 3431 - 3441
  • [32] APPLICATION OF HIGH RESOLUTION TRANSMISSION X-RAY TOMOGRAPHY IN MATERIAL SCIENCE
    Wang Shaogang
    Wang Sucheng
    Zhang Lei
    ACTA METALLURGICA SINICA, 2013, 49 (08) : 897 - 910
  • [33] Accelerator-based neutron tomography cooperating with X-ray radiography
    Kamiyama, Takashi
    Tsukui, Daisuke
    Sato, Hirotaka
    Kiyanagi, Yoshiaki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 651 (01) : 28 - 31
  • [34] 4D X-Ray Tomography with Millisecond Temporal Resolution
    Yashiro, Wataru
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2024, 90 (12): : 896 - 900
  • [35] NIST NeXT: a system for truly simultaneous neutron and X-ray tomography
    LaManna, J. M.
    Hussey, D. S.
    DiStefano, V. H.
    Baltic, E.
    Jacobson, D. L.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXII, 2020, 11494
  • [36] X-Ray Tomography of High Pressure Fuel Spray by Polycapillary Optics
    Marchitto, Luca
    Dabagov, Sultan B.
    Allocca, Luigi
    Hampai, Dariush
    Liedl, Andrea
    Alfuso, Salvatore
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VIII, 2013, 8848
  • [37] Soft X-ray microscopy with a cryo scanning transmission X-ray microscope: II. Tomography
    Wang, Y
    Jacobsen, C
    Maser, J
    Osanna, A
    JOURNAL OF MICROSCOPY-OXFORD, 2000, 197 : 80 - 93
  • [39] Thomson scattering X-ray source: a novel tool for monochromatic computed to mography
    Chi, Zhijun
    Du, Yingchao
    Yan, Lixin
    Zhou, Zheng
    Zhang, Zhen
    Wang, Dong
    Tian, Qili
    Zhang, Hongze
    Hua, Jiafei
    Shi, Jiaru
    Huang, Wenhui
    Chen, Huaibi
    Tang, Chuanxiang
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [40] X-ray computed tomography in large bubble columns
    Hubers, JL
    Striegel, AC
    Heindel, TJ
    Gray, JN
    Jensen, TC
    CHEMICAL ENGINEERING SCIENCE, 2005, 60 (22) : 6124 - 6133