Bilateral C1-C2 Claw for Atlantoaxial Instability

被引:3
|
作者
Hanimoglu, Hakan [1 ]
Hanci, Lale [2 ]
Kaynar, Mehmet Yasar [1 ]
Hanci, Murat [1 ]
机构
[1] IU Cerrahpasa Med Fac, Dept Neurosurg, Istanbul, Turkey
[2] Bone & Joint Disorders Res & Educ Hosp, Istanbul, Turkey
关键词
Atlantoaxial instability; Claw systems; Transverse connector; TRANSARTICULAR SCREW FIXATION; ROTATION; PLATE;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Atlantoaxial stability can be achieved by laminar hook systems via posterior approach. This technique is much more safer than using screws. We presented our experience with the C1-C2 claw procedure. METHODS and MATERIAL: Seven patients with atlantoaxial instability were operated by using C1 and C2 hooks, rods and transverse connector at Neurosurgery Clinic of Istanbul University Cerrahpasa Medical Faculty between the years 2005 and 2008. RESULTS: Satisfactory stabilization was achieved in all patients. Operative complication or instrumentation failure was not observed. CONCLUSIONS: C1-C2 claw is a safe technique and adequate stabilization is achieved with the use of a transverse connector.
引用
收藏
页码:345 / 348
页数:4
相关论文
共 50 条
  • [1] C1-C2 Posterior Segmental Fixation For Traumatic Atlantoaxial Instability
    Eser, Olcay
    Karavelioglu, Ergun
    Turkoglu, Mehmet Erhan
    JOURNAL OF NEUROLOGICAL SCIENCES-TURKISH, 2014, 31 (01): : 99 - 106
  • [2] Usefulness of titanium mesh cage for posterior C1-C2 fixation in patients with atlantoaxial instability
    Yang, Hwan-Seo
    Kim, Ki-Wan
    Oh, Young-Min
    Eun, Jong-Pil
    MEDICINE, 2017, 96 (36)
  • [3] C1-C2 transarticular screw fixation for treatment of C1-C2 instability
    Coyne, TJ
    Fehlings, MG
    Martin, RJ
    JOURNAL OF CLINICAL NEUROSCIENCE, 1996, 3 (03) : 243 - 246
  • [4] The Role of Transverse Connectors in C1-C2 fixation for Atlantoaxial Instability: Is It Necessary? A Biomechanical Study
    Li, Teng
    Ma, Chao
    Du, Yue-Qi
    Qiao, Guang-Yu
    Yu, Xin-Guang
    Yin, Yi-Heng
    WORLD NEUROSURGERY, 2020, 140 : E212 - E218
  • [5] C1-c2 fusion in children with atlantoaxial instability and spinal cord compression: Technical note
    Levy, ML
    McComb, JG
    NEUROSURGERY, 1996, 38 (01) : 211 - 215
  • [6] C1-C2 transarticular screw fixation for atlantoaxial instability: A 6-year experience
    Haid, RW
    Subach, BR
    McLaughlin, MR
    Rodts, GE
    Wahlig, JB
    NEUROSURGERY, 2001, 49 (01) : 65 - 68
  • [7] Feasibility and Safety of Goel-Harms Posterior C1-C2 Fusion in the Management of Pediatric Reducible Atlantoaxial Instability
    Abou-Madawi, Ali M.
    Ali, Sherif H.
    Alaswad, Mohammed
    Elkazaz, Mohamed K.
    Abdelaziz, Mohamed A.
    AlQazzaz, Mohamed Y.
    Al-Shatoury, Hassan A.
    WORLD NEUROSURGERY, 2021, 155 : E592 - E599
  • [8] Computer-assisted C1-C2 Transarticular Screw Fixation "Magerl Technique" for Atlantoaxial Instability
    Uehara, Masashi
    Takahashi, Jun
    Hirabayashi, Hiroki
    Hashidate, Hiroyuki
    Ogihara, Nobuhide
    Mukaiyama, Keijiro
    Kato, Hiroyuki
    ASIAN SPINE JOURNAL, 2012, 6 (03) : 168 - 177
  • [9] Rheumatoid atlantoaxial instability treated by anterior transarticular C1-C2 fixation. Case report
    Zapalowicz, Krzysztof
    Radek, Maciej
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2013, 47 (03) : 292 - 297
  • [10] Atlantoaxial instability treated with free-hand C1-C2 fusion in a child with Morquio syndrome
    EunJi Moon
    Subum Lee
    Sangjoon Chong
    Jin Hoon Park
    Child's Nervous System, 2020, 36 : 1785 - 1789