Smart cup: A minimally-instrumented, smartphone-based point-of-care molecular diagnostic device

被引:139
作者
Liao, Shih-Chuan [1 ,3 ]
Peng, Jing [1 ]
Mauk, Michael G. [1 ]
Awasthi, Sita [2 ]
Song, Jinzhao [1 ]
Friedman, Harvey [2 ]
Bau, Haim H. [1 ]
Liu, Changchun [1 ]
机构
[1] Univ Penn, Dept Mech Engn & Appl Mech, 216 Towne Bldg,220 South 33rd St, Philadelphia, PA 19104 USA
[2] Univ Penn, Div Infect Dis, Dept Med, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Natl Pingtung Univ Sci & Technol, Dept Biomechatron Engn, Pingtung 912, Taiwan
关键词
Chemical heating; Loop mediated isothermal amplification; HSV-2 virus detection; Smartphone; Microfluidics; HERPES-SIMPLEX-VIRUS; MEDIATED ISOTHERMAL AMPLIFICATION; MICROFLUIDIC CASSETTE; DNA AMPLIFICATION; RAPID DETECTION; NUCLEIC-ACIDS; INFECTION; ASSAY; REPLICATION; HEALTH;
D O I
10.1016/j.snb.2016.01.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nucleic acid amplification-based diagnostics offer rapid, sensitive, and specific means for detecting and monitoring the progression of infectious diseases. However, this method typically requires extensive sample preparation, expensive instruments, and trained personnel. All of which hinder its use in resource limited settings, where many infectious diseases are endemic. Here, we report on a simple, inexpensive, minimally-instrumented, smart cup platform for rapid, quantitative molecular diagnostics of pathogens at the point of care. Our smart cup takes advantage of water-triggered, exothermic chemical reaction to supply heat for the nucleic acid-based, isothermal amplification. The amplification temperature is regulated with a phase-change material (PCM). The PCM maintains the amplification reactor at a constant temperature, typically, 60-65 degrees C, when ambient temperatures range from 12 to 35 degrees C. To eliminate the need for an optical detector and minimize cost, we use the smartphone's flashlight to excite the fluorescent dye and the phone camera to record real-time fluorescence emission during the amplification process. The smartphone can concurrently monitor multiple amplification reactors and analyze the recorded data. Our smart cup's utility was demonstrated by amplifying and quantifying herpes simplex virus type 2 (HSV-2) with LAMP assay in our custom-made microfluidic diagnostic chip. We have consistently detected as few as 100 copies of HSV-2 viral DNA per sample. Our system does not require any lab facilities and is suitable for use at home, in the field, and in the clinic, as well as in resource-poor settings, where access to sophisticated laboratories is impractical, unaffordable, or nonexistent. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 46 条
[1]   Miniaturized isothermal nucleic acid amplification, a review [J].
Asiello, Peter J. ;
Baeumner, Antje J. .
LAB ON A CHIP, 2011, 11 (08) :1420-1430
[2]   Status of prophylactic and therapeutic genital herpes vaccines [J].
Awasthi, Sita ;
Friedman, Harvey M. .
CURRENT OPINION IN VIROLOGY, 2014, 6 :6-12
[3]   Protection Provided by a Herpes Simplex Virus 2 (HSV-2) Glycoprotein C and D Subunit Antigen Vaccine against Genital HSV-2 Infection in HSV-1-Seropositive Guinea Pigs [J].
Awasthi, Sita ;
Balliet, John W. ;
Flynn, Jessica A. ;
Lubinski, John M. ;
Shaw, Carolyn E. ;
DiStefano, Daniel J. ;
Cai, Michael ;
Brown, Martha ;
Smith, Judith F. ;
Kowalski, Rose ;
Swoyer, Ryan ;
Galli, Jennifer ;
Copeland, Victoria ;
Rios, Sandra ;
Davidson, Robert C. ;
Salnikova, Maya ;
Kingsley, Susan ;
Bryan, Janine ;
Casimiro, Danilo R. ;
Friedman, Harvey M. .
JOURNAL OF VIROLOGY, 2014, 88 (04) :2000-2010
[4]   An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids [J].
Chen, Dafeng ;
Mauk, Michael ;
Qiu, Xianbo ;
Liu, Changchun ;
Kim, Jitae ;
Ramprasad, Sudhir ;
Ongagna, Serge ;
Abrams, William R. ;
Malamud, Daniel ;
Corstjens, Paul L. A. M. ;
Bau, Haim H. .
BIOMEDICAL MICRODEVICES, 2010, 12 (04) :705-719
[5]   NUCLEIC-ACID SEQUENCE-BASED AMPLIFICATION [J].
COMPTON, J .
NATURE, 1991, 350 (6313) :91-92
[6]   Current Concepts: Maternal and Neonatal Herpes Simplex Virus Infections. [J].
Corey, Lawrence ;
Wald, Anna .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (14) :1376-1385
[7]   Isothermal Amplification Using a Chemical Heating Device for Point-of-Care Detection of HIV-1 [J].
Curtis, Kelly A. ;
Rudolph, Donna L. ;
Nejad, Irene ;
Singleton, Jered ;
Beddoe, Andy ;
Weigl, Bernhard ;
LaBarre, Paul ;
Owen, S. Michele .
PLOS ONE, 2012, 7 (02)
[8]   Integrated microfluidic tmRNA purification and real-time NASBA device for molecular diagnostics [J].
Dimov, Ivan K. ;
Garcia-Cordero, Jose L. ;
O'Grady, Justin ;
Poulsen, Claus R. ;
Viguier, Caroline ;
Kent, Lorcan ;
Daly, Paul ;
Lincoln, Bryan ;
Maher, Majella ;
O'Kennedy, Richard ;
Smith, Terry J. ;
Ricco, Antonio J. ;
Lee, Luke P. .
LAB ON A CHIP, 2008, 8 (12) :2071-2078
[9]   A fully integrated microfluidic genetic analysis system with sample-in-answer-out capability [J].
Easley, Christopher J. ;
Karlinsey, James M. ;
Bienvenue, Joan M. ;
Legendre, Lindsay A. ;
Roper, Michael G. ;
Feldman, Sanford H. ;
Hughes, Molly A. ;
Hewlett, Erik L. ;
Merkel, Tod J. ;
Ferrance, Jerome P. ;
Landers, James P. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (51) :19272-19277
[10]   ROLLING REPLICATION OF SHORT DNA CIRCLES [J].
FIRE, A ;
XU, SQ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (10) :4641-4645