The effect of interfraction prostate motion on IMRT plans: a dose-volume histogram analysis using a Gaussian error function model

被引:9
|
作者
Chow, James C. L. [1 ,2 ,3 ,4 ]
Jiang, Runqing [5 ]
Markel, Daniel
机构
[1] Univ Hlth Network, Dept Radiat Phys, Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[3] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[4] Univ Waterloo, Dept Phys, Waterloo, ON N2L 3G1, Canada
[5] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON, Canada
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2009年 / 10卷 / 04期
关键词
dose-volume histogram; prostate IMRT; internal organ motion; error function and model fitting; ORGAN MOTION; INTRAFRACTION MOTION; RADIOTHERAPY; OPTIMIZATION; CANCER; DEFORMATION; IRRADIATION; CARCINOMA; RADIATION; THERAPY;
D O I
10.1120/jacmp.v10i4.3055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Gaussian error function model, containing pairs of error and complementary error functions, was used to carry out cumulative dose-volume histogram (cDVH) analysis on prostate intensity-modulated radiation therapy (IMRT) plans with interfraction prostate motion. Cumulative DVHs for clinical target volumes (CTVs) shifted in the anterior-posterior directions based on a 7-beam IMRT plan were calculated and modeled using the Pinnacle(3) treatment planning system and a Gaussian error function, respectively. As the parameters in the error function model (namely, a, b and c) were related to the shape of the cDVH curve, evaluation of cDVHs corresponding to the prostate motion based on the model parameters becomes possible, as demonstrated in this study. It was found that deviations of the cDVH for the CTV were significant, when the CTV-planning target volume (PTV) margin was underestimated in the anterior-posterior directions. This was especially evident in the posterior direction for a patient with relatively small prostate volume (39 cm(3)). Analysis of the cDVH for the CTV shifting in the anterior-posterior directions using the error function model showed that parameters a(1,2), which were related to the maximum relative volume of the cDVH, changed symmetrically when the prostate was shifted in the anterior and posterior directions. This change was more significant for the larger prostate. For parameters b related to the slope of the cDVH, b(1,2) changed symmetrically from the isocenter, when the CTV was within the PTV. This was different from parameters c (c(1,2) are related to the maximum dose of the cDVH), which did not vary significantly with the prostate motion in the anterior-posterior directions and prostate volume. Using the patient data, this analysis validated the error function model, and further verified the clinical application of this mathematical model on treatment plan evaluations.
引用
收藏
页码:79 / 95
页数:17
相关论文
共 50 条
  • [41] Dose-volume histogram analysis of brainstem necrosis in head and neck tumors treated using carbon-ion radiotherapy
    Shirai, Katsuyuki
    Fukata, Kyohei
    Adachi, Akiko
    Saitoh, Jun-ichi
    Musha, Atsushi
    Abe, Takanori
    Kanai, Tatsuaki
    Kobayashi, Daijiro
    Shigeta, Yuka
    Yokoo, Satoshi
    Chikamatsu, Kazuaki
    Ohno, Tatsuya
    Nakano, Takashi
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (01) : 36 - 40
  • [42] Risk factors for neovascular glaucoma after carbon ion radiotherapy of choroidal melanoma using dose-volume histogram analysis
    Hirasawa, Naoki
    Tsuji, Hiroshi
    Ishikawa, Hitoshi
    Koyama-Ito, Hiroko
    Kamada, Tadashi
    Mizoe, Jun-Etsu
    Ito, Yoshiyuki
    Naganawa, Shinji
    Ohnishi, Yoshitaka
    Tsujii, Hirohiko
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (02): : 538 - 543
  • [43] COMPARATIVE DOSE-VOLUME ANALYSIS FOR FRACTIONATED RADIOTHERAPY OF CENTRAL BRAIN TUMORS IN PEDIATRIC PATIENTS USING CYBERKINFE, IMRT, AND BRAINLAB
    Heinzerling, J.
    Timmerman, C.
    Hong, Z.
    Ramirez, E.
    Ding, C.
    Foster, R.
    Solberg, T.
    Timmerman, R.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S566 - S566
  • [44] Dosimetric predictors of patient-reported toxicity after prostate stereotactic body radiotherapy: Analysis of full range of the dose-volume histogram using ensemble machine learning
    Pan, Xiaoying
    Levin-Epstein, Rebecca
    Huang, Jiahao
    Ruan, Dan
    King, Christopher R.
    Kishan, Amar U.
    Steinberg, Michael L.
    Qi, X. Sharon
    RADIOTHERAPY AND ONCOLOGY, 2020, 148 : 181 - 188
  • [45] Comparison of adverse effects of proton and X-ray chemoradiotherapy for oesophageal cancer using an adaptive dose-volume histogram analysis
    Makishima, H.
    Ishikawa, H.
    Terunuma, T.
    Hashimoto, T.
    Yamanashi, K.
    Sekiguchi, T.
    Mizumoto, M.
    Okumura, T.
    Tsuboi, K.
    Sakurai, H.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S576 - S576
  • [46] Comparison of adverse effects of proton and X-ray chemoradiotherapy for esophageal cancer using an adaptive dose-volume histogram analysis
    Makishima, Hirokazu
    Ishikawa, Hitoshi
    Terunuma, Toshiyuki
    Hashimoto, Takayuki
    Yamanashi, Koichi
    Sekiguchi, Takao
    Mizumoto, Masashi
    Okumura, Toshiyuki
    Sakae, Takeji
    Sakurai, Hideyuki
    JOURNAL OF RADIATION RESEARCH, 2015, 56 (03) : 568 - 576
  • [47] Analysis of interaction between number of implant catheters and dose-volume histograms in prostate highdose-rate brachytherapy using a computer model
    Charra-Brunaud, C
    Hsu, ICJ
    Weinberg, V
    Pouliot, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02): : 586 - 591
  • [48] Evaluation of prostate IMRT treatment planning incorporating internal organ motion using a dose gradient analysis
    Jiang, R.
    Barnett, R.
    Chow, J. C. L.
    Chen, J. Z. Y.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S68 - S69
  • [49] Defining the risk of developing grade 2 proctitis following combined modality therapy using a rectal dose-volume histogram analysis and biologic equivalent dose
    Snyder, K. M.
    Skouteris, V. M.
    Stone, N. N.
    Cesaretti, J. A.
    Stock, R. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S333 - S333
  • [50] Magnitude of observer error using cone beam CT for prostate interfraction motion estimation: effect of reducing scan length or increasing exposure
    McNair, Helen A.
    Harris, Emma J.
    Hansen, Vibeke N.
    Thomas, Karen
    South, Christopher
    Hafeez, Shaista
    Huddart, Robert
    Dearnaley, David P.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1054):