A randomized controlled comparison of non-channeled king vision, McGrath MAC video laryngoscope and Macintosh direct laryngoscope for nasotracheal intubation in patients with predicted difficult intubations

被引:23
作者
Zhu, Haozhen [1 ]
Liu, Jinxing [1 ]
Suo, Lulu [1 ]
Zhou, Chi [1 ]
Sun, Yu [1 ]
Jiang, Hong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Shanghai Peoples Hosp 9, Dept Anesthesiol, 639 Zhizaoju Rd, Shanghai 200011, Peoples R China
关键词
Airway management; video laryngoscopes; Nasotracheal intubation; CONTROLLED-TRIAL; GLIDESCOPE(R) VIDEOLARYNGOSCOPY; TRACHEAL INTUBATION; NASAL INTUBATION; AIRWAY; ANESTHETISTS; HEAD;
D O I
10.1186/s12871-019-0838-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background King Vision and McGrath MAC video laryngoscopes (VLs) are increasingly used. The purpose of this study was to evaluate the performance of nasotracheal intubation in patients with predicted difficult intubations using non-channeled King Vision VL, McGrath MAC VL or Macintosh laryngoscope by experienced intubators. Methods Ninety nine ASA I or II adult patients, scheduled for oral maxillofacial surgeries with El-Ganzouri risk index 1-7 were enrolled. Patients were randomly allocated to intubate with one of three laryngoscopes (non-channeled King Vision, McGrath MAC and Macintosh). The intubators were experienced with more than 100 successful nasotracheal intubations using each device. The primary outcome was intubation time. The secondary outcomes included first success rate, time required for viewing the glottis, Cormack-Lehane grade of glottis view, the number of assist maneuvers, hemodynamic responses, the subjective evaluating of sensations of performances and associated complications. Results The intubation time of King Vision and McGrath group was comparable (37.6 +/- 7.3 s vs. 35.4 +/- 8.8 s) and both were shorter than Macintosh group (46.8 +/- 10.4 s, p < 0.001). Both King Vision and McGrath groups had a 100% first attempt success rate, significantly higher than Macintosh group (85%, p < 0.05). The laryngoscopy time was comparable between King Vision and McGrath group (16.7 +/- 5.5 s vs. 15.6 +/- 6.3 s) and was shorter than Macintosh group (22.8 +/- 7.2 s, p < 0.05) also. Compared with Macintosh laryngoscope, Glottis view was obviously improved when exposed with either non-channeled King Vision or McGrath MAC VL (p < 0.001), and assist maneuvers required were reduced (p < 0.001). The maximum fluctuations of MAP were significantly attenuated in VL groups (47.7 +/- 12.5 mmHg and 45.1 +/- 10.3 mmHg vs. 54.9 +/- 10.2 mmHg, p < 0.05 and p < 0.01). Most device insertions were graded as excellent in McGrath group, followed by Macintosh and King Vision group (p = 0.0014). The tube advancements were easier in VLs compared with the Macintosh laryngoscope (p < 0.001). Sore throat was found more frequent in Macintosh group compared with King Vision group (p < 0.05). Conclusions Non-channeled King Vision and McGrath MAC VLs were comparable and both devices facilitated nasotracheal intubation in managing predicted difficult intubations compared with Macintosh laryngoscope.
引用
收藏
页数:9
相关论文
共 50 条
[41]   Comparison of UESCOPE VL 400, I-View, Non-Channeled Airtraq Videolaryngoscopes and Macintosh Laryngoscope for Tracheal Intubation in Simulated Out-of-Hospital Conditions: A Randomized Crossover Manikin Study [J].
Ratajczyk, Pawel ;
Dolder, Przemyslaw ;
Szmyd, Bartosz ;
Gomez-Rios, Manuel A. ;
Hogendorf, Piotr ;
Durczynski, Adam ;
Gaszynski, Tomasz .
HEALTHCARE, 2024, 12 (04)
[42]   Comparison of Macintosh Laryngoscope, King Vision®, VividTrac®, AirAngel Blade®, and a Custom-Made 3D-Printed Video Laryngoscope for Difficult and Normal Airways in Mannequins by Novices-A Non-Inferiority Trial [J].
Bacher, Viktor ;
Nemeth, Marton ;
Rendeki, Szilard ;
Tornai, Balazs ;
Rozanovic, Martin ;
Pankaczi, Andrea ;
Olah, Janos ;
Farkas, Jozsef ;
Chikhi, Melania ;
Schlegl, Adam ;
Maroti, Peter ;
Nagy, Balint .
JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
[43]   Double-lumen tube tracheal intubation using a rigid video-stylet: a randomized controlled comparison with the Macintosh laryngoscope [J].
Yang, M. ;
Kim, J. A. ;
Ahn, H. J. ;
Choi, J. W. ;
Kim, D. K. ;
Cho, E. A. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (06) :990-995
[44]   Flexible bronchoscope versus video-laryngoscope for nasotracheal intubation in patients with anticipated difficult airway under topical anesthesia and dexmedetomidine infusion: A randomized controlled trial [J].
Kundu, Aritra ;
Patel, Nishant ;
Baidya, Dalim Kumar ;
Ayub, Arshad ;
Goswami, Devalina ;
Kumar, Kanil Ranjith ;
Kumar, Rakesh ;
Kumar, Shailendra ;
Roychoudhury, Ajoy .
TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2025, 61
[45]   Is Video Laryngoscope-Assisted Flexible Tracheoscope Intubation Feasible for Patients with Predicted Difficult Airway? A Prospective, Randomized Clinical Trial [J].
Lenhardt, Rainer ;
Burkhart, Mary Tyler ;
Brock, Guy N. ;
Kanchi-Kandadai, Sunitha ;
Sharma, Rachana ;
Akca, Ozan .
ANESTHESIA AND ANALGESIA, 2014, 118 (06) :1259-1265
[46]   Comparative Evaluation of Ease of Nasotracheal Intubation Using C-MAC versus TuoRen Video Laryngoscope in Adult Surgical Patients: A Randomized Study [J].
Rajan, Sunil ;
Chandrasekharan, Rejitha ;
Mathew, Jacob ;
Roy, Roniya Ann ;
Rajkumar, Reshma ;
Paul, Jerry .
JOURNAL OF HEAD & NECK PHYSICIANS AND SURGEONS, 2024, 12 (01) :69-73
[47]   Comparison of the C-MAC D-blade video laryngoscope and the McCoy laryngoscope for double-lumen endotracheal tube intubation A prospective randomized controlled study [J].
Kim, Kyung Mi ;
Seo, Kwon Hui ;
Kim, You Jung ;
John, Hyunji ;
Moon, Hyun Soo ;
Kim, Namhyun ;
Yeon, Nayoung .
MEDICINE, 2022, 101 (45) :E31775
[48]   Comparison of video laryngoscope, video stylet, and flexible videoscope for transoral endotracheal intubation in patients with difficult airways: a randomized, parallel-group study [J].
Zhang, Tao ;
Zhao, Kai-Yuan ;
Zhang, Ping ;
Li, Ren-Hu .
TRIALS, 2023, 24 (01)
[49]   Comparison of a New Video Intubation Stylet and McGrath® MAC Video Laryngoscope for Intubation in an Airway Manikin with Normal Airway and Cervical Spine Immobilization Scenarios by Novice Personnel: A Randomized Crossover Study [J].
Park, Jin-Woo ;
An, Sungmin ;
Park, Seongjoo ;
Nahm, Francis Sahngun ;
Han, Sung-Hee ;
Kim, Jin-Hee .
BIOMED RESEARCH INTERNATIONAL, 2021, 2021
[50]   Comparison of the C-MAC D-Blade videolaryngoscope and direct laryngoscope in pediatric patients: Randomized controlled trial [J].
Hajiyeva, Konul ;
Can, Ozlem Selvi ;
Baytas, Volkan ;
Guclu, Cigdem Yildirim .
ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2021, 27 (04) :421-426