摘要
Background King Vision and McGrath MAC video laryngoscopes (VLs) are increasingly used. The purpose of this study was to evaluate the performance of nasotracheal intubation in patients with predicted difficult intubations using non-channeled King Vision VL, McGrath MAC VL or Macintosh laryngoscope by experienced intubators. Methods Ninety nine ASA I or II adult patients, scheduled for oral maxillofacial surgeries with El-Ganzouri risk index 1-7 were enrolled. Patients were randomly allocated to intubate with one of three laryngoscopes (non-channeled King Vision, McGrath MAC and Macintosh). The intubators were experienced with more than 100 successful nasotracheal intubations using each device. The primary outcome was intubation time. The secondary outcomes included first success rate, time required for viewing the glottis, Cormack-Lehane grade of glottis view, the number of assist maneuvers, hemodynamic responses, the subjective evaluating of sensations of performances and associated complications. Results The intubation time of King Vision and McGrath group was comparable (37.6 +/- 7.3 s vs. 35.4 +/- 8.8 s) and both were shorter than Macintosh group (46.8 +/- 10.4 s, p < 0.001). Both King Vision and McGrath groups had a 100% first attempt success rate, significantly higher than Macintosh group (85%, p < 0.05). The laryngoscopy time was comparable between King Vision and McGrath group (16.7 +/- 5.5 s vs. 15.6 +/- 6.3 s) and was shorter than Macintosh group (22.8 +/- 7.2 s, p < 0.05) also. Compared with Macintosh laryngoscope, Glottis view was obviously improved when exposed with either non-channeled King Vision or McGrath MAC VL (p < 0.001), and assist maneuvers required were reduced (p < 0.001). The maximum fluctuations of MAP were significantly attenuated in VL groups (47.7 +/- 12.5 mmHg and 45.1 +/- 10.3 mmHg vs. 54.9 +/- 10.2 mmHg, p < 0.05 and p < 0.01). Most device insertions were graded as excellent in McGrath group, followed by Macintosh and King Vision group (p = 0.0014). The tube advancements were easier in VLs compared with the Macintosh laryngoscope (p < 0.001). Sore throat was found more frequent in Macintosh group compared with King Vision group (p < 0.05). Conclusions Non-channeled King Vision and McGrath MAC VLs were comparable and both devices facilitated nasotracheal intubation in managing predicted difficult intubations compared with Macintosh laryngoscope.
引用
收藏
页数:9
相关论文
共 50 条
[31]   Intubation of non-difficult airways using video laryngoscope versus direct laryngoscope: a randomized, parallel-group study [J].
Liu, De-Xing ;
Ye, Ying ;
Zhu, Yu-Hang ;
Li, Jing ;
He, Hong-Ying ;
Dong, Liang ;
Zhu, Zhao-Qiong .
BMC ANESTHESIOLOGY, 2019, 19
[32]   Comparison of the McGrath MAC EMS Videolaryngoscope with a Conventional Laryngoscope for Standard and Difficult Airway Intubation: A Randomized, Cross-over, Simulation Trial [J].
Korkut, Semih ;
Szarpak, Lukasz ;
Evrin, Togay ;
Smereka, Jacek ;
Katipoglu, Burak ;
Gorczyca, Damian .
EURASIAN JOURNAL OF EMERGENCY MEDICINE, 2019, 18 (04) :211-217
[33]   A Comparison of Tracheal Intubation Using Direct Laryngoscope and Video Laryngoscope in the Sellick and Trendelenburg Position with That Using Direct Laryngoscope in the Supine Sniffing Position: A Randomized Controlled Trial [J].
Chae, Yun-Jeong ;
Moon, Jung-Yoon ;
Lee, Min-Gyu ;
Joe, Han-Bum .
JOURNAL OF CLINICAL MEDICINE, 2024, 13 (15)
[34]   Comparative evaluation of C-MAC and McGrath MAC videolaryngoscopes with Macintosh direct laryngoscope for endotracheal intubation in adult patients undergoing elective surgeries [J].
Abhyankar, Prachi ;
Sabharwal, Nikki ;
Gupta, Anju ;
Das, Akshaya K. .
JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2023, 39 (03) :422-428
[35]   Does C-MAC (R) video laryngoscope improve the nasotracheal intubating conditions compared to Macintosh direct laryngoscope in paediatric patients posted for tonsillectomy surgeries? [J].
Patil, Vinuta V. ;
Subramanya, Bala H. ;
Kiranchand, N. ;
Bhaskar, S. Bala ;
Dammur, Srinivasalu .
INDIAN JOURNAL OF ANAESTHESIA, 2016, 60 (10) :732-736
[36]   Comparison of Efficacy of Intubation with HugeMed Non-channelled Video Laryngoscope, McCoy and Macintosh Laryngoscope in Simulated Difficult Laryngoscopy Using Rigid Cervical Collar: A Prospective Randomized Trial [J].
Murdeshwar, Greeshma N. ;
Yashodha, V. ;
Poolandevi, Kempaiah ;
Malini, S. .
ANNALS OF AFRICAN MEDICINE, 2024, 23 (03) :358-364
[37]   Comparison of the McGrath videolaryngoscope and the Macintosh laryngoscope for double lumen endobronchial tube intubation in patients with manual in-line stabilization: A randomized controlled trial [J].
Yoo, Ji Young ;
Park, Sung Yong ;
Kim, Jong Yeop ;
Kim, Myungseob ;
Haam, Seok Jin ;
Kim, Dae Hee .
MEDICINE, 2018, 97 (10)
[38]   Measurement of forces applied using a Macintosh direct laryngoscope compared with a Glidescope video laryngoscope in patients with predictors of difficult laryngoscopy A randomised controlled trial [J].
Cordovani, Daniel ;
Russell, Twain ;
Wee, Wallace ;
Suen, Andrew ;
Cooper, Richard M. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2019, 36 (03) :221-226
[39]   Comparison of endotracheal intubation with Macintosh versus King Vision video laryngoscope using coronavirus disease 2019 barrier box on manikins: A randomized crossover study [J].
Guru, Satyabrata ;
Singh, Neha ;
Sahoo, Sangeeta ;
Hansda, Upendra ;
Mohanty, Chittaranjan .
TURKISH JOURNAL OF EMERGENCY MEDICINE, 2022, 22 (03) :149-155
[40]   Comparison of UESCOPE VL 400, I-View, Non-Channeled Airtraq Videolaryngoscopes and Macintosh Laryngoscope for Tracheal Intubation in Simulated Out-of-Hospital Conditions: A Randomized Crossover Manikin Study [J].
Ratajczyk, Pawel ;
Dolder, Przemyslaw ;
Szmyd, Bartosz ;
Gomez-Rios, Manuel A. ;
Hogendorf, Piotr ;
Durczynski, Adam ;
Gaszynski, Tomasz .
HEALTHCARE, 2024, 12 (04)