Exclusion criteria for assuring safety of single-incision laparoscopic cholecystectomy

被引:0
作者
Kawaguchi, Yoshikuni [1 ]
Ishizawa, Takeaki [1 ]
Nagata, Rihito [1 ]
Kaneko, Junichi [1 ]
Sakamoto, Yoshihiro [1 ]
Aoki, Taku [1 ]
Sugawara, Yasuhiko [1 ]
Hasegawa, Kiyoshi [1 ]
Kokudo, Norihiro [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Surg, Hepatobiliary Pancreat Surg Div, Tokyo, Japan
关键词
Conventional multiport laparoscopic cholecystectomy; fluorescence cholangiography; single-incision laparoscopic cholecystectomy; BILE-DUCT INJURY; INITIAL-EXPERIENCE; CHOLANGIOGRAPHY; INSTRUMENTS; SURGERY; TRIAL; COST; SITE;
D O I
10.5582/bst.2015.01143
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Despite increasing popularity of single-incision laparoscopic cholecystectomy (SILC), indication criteria assuring safety of SILC has yet to be established. In the present study, the subjects consisted of 146 consecutive patients undergoing conventional laparoscopic cholecystectomy (CLC) or SILC. SILC was indicated after excluding patients who met following criteria: age > 75 years, obesity, operative scar, cardiopulmonary diseases, acute cholecystitis, choledocholithiasis and abnormal bile duct anatomy. Thirty-four patients were excluded from the SILC candidates (moderate/high-risk CLC group). Among the 112 potential candidates, SILC was indicated for 23 patients (21%, SILC group) and the remaining 89 patients (79%) underwent CLC (low-risk CLC group). In the SILC group, operation time was longer than in the low-risk CLC group (171 [113-286] vs. 126 [72-240] min, p < 0.01), but the periods requiring painkiller was shorter. That led to reduced length of hospital stay compared to low-risk CLC group (2 [2-4] vs. 4 [2-12] days, p < 0.01). Between the low-risk CLC and moderate/high-risk CLC group, operation time was significantly longer and amount of blood loss was larger in the latter group. No complications were encountered in the SILC group. SILC can be indicated safely as far as appropriate criteria is adopted for excluding patients in whom complicated laparoscopic procedures are needed.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 29 条
[1]   Single-port endoscopic cholecystectomy: a bridge between laparoscopic and translumenal endoscopic surgery [J].
Abe, Nobutsugu ;
Takeuchi, Hirohisa ;
Ueki, Hisayo ;
Yanagida, Osamu ;
Masaki, Tadahiko ;
Mori, Toshiyuki ;
Sugiyama, Masanori ;
Atomi, Yutaka .
JOURNAL OF HEPATO-BILIARY-PANCREATIC SURGERY, 2009, 16 (05) :633-638
[2]   Intraoperative fluorescent imaging using indocyanine green for liver mapping and cholangiography [J].
Aoki, Takeshi ;
Murakami, Masahiko ;
Yasuda, Daisuke ;
Shimizu, Yoshinori ;
Kusano, Tomokazu ;
Matsuda, Kazuhiro ;
Niiya, Takashi ;
Kato, Hirohisa ;
Murai, Noriyuki ;
Otsuka, Koji ;
Kusano, Mitsuo ;
Kato, Takashi .
JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2010, 17 (05) :590-594
[3]   Laparoendoscopic Single Site (LESS) Versus Classic Video-Laparoscopic Cholecystectomy: A Randomized Prospective Study [J].
Aprea, Giovanni ;
Bottazzi, Enrico Coppola ;
Guida, Francesco ;
Masone, Stefania ;
Persico, Giovanni .
JOURNAL OF SURGICAL RESEARCH, 2011, 166 (02) :E109-E112
[4]   Randomized clinical trial of laparoendoscopic single-site versus conventional laparoscopic cholecystectomy [J].
Bucher, P. ;
Pugin, F. ;
Buchs, N. C. ;
Ostermann, S. ;
Morel, P. .
BRITISH JOURNAL OF SURGERY, 2011, 98 (12) :1695-1702
[5]   Real-time near-infrared fluorescent cholangiography could shorten operative time during robotic single-site cholecystectomy [J].
Buchs, Nicolas C. ;
Pugin, Francois ;
Azagury, Dan E. ;
Jung, Minoa ;
Volonte, Francesco ;
Hagen, Monika E. ;
Morel, Philippe .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (10) :3897-3901
[6]   Single-incision laparoscopic appendectomy using conventional instruments: an initial experience using a novel technique [J].
Chiu, Connie G. ;
Nguyen, Nam H. ;
Bloom, Scott W. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (04) :1153-1159
[7]  
Culp Brittney L, 2012, Proc (Bayl Univ Med Cent), V25, P319
[8]   Single-port-access (SPATM) cholecystectomy: a multi-institutional report of the first 297 cases [J].
Curcillo, Paul G., II ;
Wu, Andrew S. ;
Podolsky, Erica R. ;
Graybeal, Casey ;
Katkhouda, Namir ;
Saenz, Alex ;
Dunham, Robert ;
Fendley, Steven ;
Neff, Marc ;
Copper, Chad ;
Bessler, Marc ;
Gumbs, Andrew A. ;
Norton, Michael ;
Iannelli, Antonio ;
Mason, Rodney ;
Moazzez, Ashkan ;
Cohen, Larry ;
Mouhlas, Angela ;
Poor, Alex .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2010, 24 (08) :1854-1860
[9]   Retraction and triangulation with neodymium magnetic forceps for single-port laparoscopic cholecystectomy [J].
Dominguez, Guillermo ;
Durand, Luis ;
De Rosa, Julian ;
Danguise, Eduardo ;
Arozamena, Carlos ;
Ferraina, Pedro A. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (07) :1660-1666
[10]   Initial Experience with Single-Incision Laparoscopic Cholecystectomy Discussion [J].
Rosemurgy, Alexander S. ;
Heniford, B. Todd ;
Voyles, Randy ;
Pellegrini, Carlos ;
Elsey, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2010, 210 (05) :624-626