Characterization of adrenal lesions on chemical shift MRI: comparison of 1.5 T and 3 T MRI

被引:2
作者
Hekimsoy, Ilhan [1 ]
Guler, Ezgi [1 ]
Harman, Mustafa [1 ]
Elmas, Nevra [1 ]
机构
[1] Ege Univ, Sch Med, Dept Radiol, TR-35100 Izmir, Turkey
关键词
Adrenal adenoma; Adrenal glands; Chemical shift imaging; MRI; TIME PAIR SELECTION; IN-PHASE; CT; PREVALENCE; PRINCIPLES; TUMOR; MASS;
D O I
10.1007/s00261-019-02067-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To compare three chemical shift MRI techniques [two-dimensional (2D) dual gradient echo (dGRE), 3D VIBE, and 3D VIBE-Dixon] at 3 T and 2D dGRE technique at 1.5 T to assess their ability of detecting microscopic fat in adrenal adenomas and differentiating between adenomas and non-adenomas. Methods Seventy-eight patients with 97 lesions (78 adenomas, 19 non-adenomas) underwent both 1.5 T and 3 T chemical shift MRI. The Wilcoxon signed-ranked test was used to determine if there was significant difference between the signal intensity index (SII) values of each technique to assess their ability to detect microscopic fat in adrenal adenomas. ROC analysis was performed for the SII values of each technique, the adrenal-to-spleen SI ratio of 2D dGRE technique at 3 T, and the fat fraction values of the 3D VIBE-Dixon technique to identify the optimal threshold for differentiation of adrenal adenomas from non-adenomas. Results For detection of microscopic fat, the mean SII value of 2D dGRE technique at 1.5 T was significantly higher than that of the chemical shift imaging techniques at 3 T (p = 0.001). For discrimination of adenomas from non-adenomas, the area under the curve (AUC) and 95% confidence interval values of 2D dGRE technique at 1.5 T and 2D dGRE, 3D VIBE, 3D VIBE-Dixon techniques at 3 T were calculated as 1.00 (1.00-1.00), 0.991 (0.978-1.00), 0.999 (0.995-1.00), 0.993 (0.979-1.00), respectively, for the SII. Conclusion Chemical shift MRI at 1.5 T using the 2D dGRE technique provided the most accurate differentiation between adenomas and non-adenomas. However, there was no statistically significant difference between chemical shift imaging techniques at 1.5 T and 3 T.
引用
收藏
页码:3359 / 3369
页数:11
相关论文
共 25 条
[1]   Chemical Shift MR Imaging of the Adrenal Gland: Principles, Pitfalls, and Applications [J].
Adam, Sharon Z. ;
Nikolaidis, Paul ;
Horowitz, Jeanne M. ;
Gabriel, Helena ;
Hammond, Nancy A. ;
Patel, Tanvi ;
Yaghmai, Vahid ;
Miller, Frank H. .
RADIOGRAPHICS, 2016, 36 (02) :414-432
[2]   Adrenal Imaging [J].
Blake, Michael A. ;
Cronin, Carmel G. ;
Boland, Giles W. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) :1450-1460
[3]   Incidental Adrenal Lesions: Principles, Techniques, and Algorithms for Imaging Characterization [J].
Boland, Giles W. L. ;
Blake, Michael A. ;
Hahn, Peter F. ;
Mayo-Smith, William W. .
RADIOLOGY, 2008, 249 (03) :756-775
[4]   Prevalence of adrenal incidentaloma in a contemporary computerized tomography series [J].
Bovio, S. ;
Cataldi, A. ;
Reimondo, G. ;
Sperone, P. ;
Novello, S. ;
Berruti, A. ;
Borasio, P. ;
Fava, C. ;
Dogliotti, L. ;
Scagliotti, G. V. ;
Angeli, A. ;
Terzolo, M. .
JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2006, 29 (04) :298-302
[5]   Review - Imaging of adrenal incidentalomas: Current status [J].
Dunnick, NR ;
Korobkin, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (03) :559-568
[6]   Characterization of adrenal tumors by chemical shift fast low-angle shot MR imaging: Comparison of four methods of quantitative evaluation [J].
Fujiyoshi, F ;
Nakajo, M ;
Fukukura, Y ;
Tsuchimochi, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (06) :1649-1657
[7]   Dual-Energy CT for Characterization of Adrenal Nodules: Initial Experience [J].
Gupta, Rajan T. ;
Ho, Lisa M. ;
Marin, Daniele ;
Boll, Daniel T. ;
Barnhart, Huiman X. ;
Nelson, Rendon C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) :1479-1483
[8]   Lipid-poor adenomas on unenhanced CT: Does histogram analysis increase sensitivity compared with a mean attenuation threshold? [J].
Ho, Lisa M. ;
Paulson, Erik K. ;
Brady, Matthew J. ;
Wong, Terence Z. ;
Schindera, Sebastian T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) :234-238
[9]   Effectiveness of a three-dimensional dual gradient echo two-point Dixon technique for the characterization of adrenal lesions at 3 Tesla [J].
Marin, Daniele ;
Dale, Brian M. ;
Bashir, Mustafa R. ;
Ziemlewicz, Timothy J. ;
Ringe, Kristina I. ;
Boll, Daniel T. ;
Merkle, Elmar M. .
EUROPEAN RADIOLOGY, 2012, 22 (01) :259-268
[10]   Characterization of Adrenal Lesions: Comparison of 2D and 3D Dual Gradient-Echo MR Imaging at 3 T-Preliminary Results [J].
Marin, Daniele ;
Soher, Brian J. ;
Dale, Brian M. ;
Boll, Daniel T. ;
Youngblood, Richard S. ;
Merkle, Elmar M. .
RADIOLOGY, 2010, 254 (01) :179-187