Effect of b values and size of region of interest on apparent diffusion coefficient measurement and its reproducibility in liver diffusion-weighted MRI

被引:1
作者
Huang, Yucun [1 ]
Xie, Liling [1 ]
Cao, Zhi [1 ]
Lu, Shaofan [1 ]
Huang, Shengfu [1 ]
机构
[1] Fifth Peoples Hosp Zhuhai, Dept Radiol, Zhuhai, Guangdong, Peoples R China
关键词
Liver diffusion-weighted imaging; Apparent diffusion coefficient; b values; Region of interest; Reproducibility; ADC MEASUREMENTS; BREATH-HOLD; CHRONIC HEPATITIS; DIAGNOSIS; PERFUSION; FIBROSIS; AGREEMENT; LESIONS; TESLA;
D O I
10.1007/s42058-021-00053-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo investigate the effect of b value and size of region of interest (ROI) on apparent diffusion coefficient (ADC) measurement and its reproducibility in liver diffusion-weighted imaging (DWI).MethodsThirty-six volunteers underwent liver DWI twice with b values of 0, 100, 500, and 800 s/mm(2). ADCs were measured with ROI of 50 mm(2) on ADC maps generated with different b values of (0, 100), (0, 500), (0, 800), (0, 100, 500), (0, 100, 800), (0, 500, 800), and (0, 100, 500, 800) s/mm(2). ADCs from b values of (0, 800) s/mm(2) were measured with 4 ROI sizes (50, 100, 200 and 300 mm(2)). ANOVA analysis was used to compare differences of ADCs among different ROI sizes and different combined b values. Bland-Altman method was used to assess reproducibility of ADC measurement.ResultsADCs with larger ROI size were slightly higher than those with smaller one, while no statistical difference was found (P > 0.05). And reproducibility of ADC measurement with different ROI sizes was comparable (LOA 7.0-8.2% for right lobe, 14.15-17.4% for left lobe). ADCs statistically decreased with increased maximum b values (P < 0.05). ADC measurement achieved the best reproducible with maximum b value of 800 s/mm(2) regardless of the number of b values.ConclusionsThe b values influence ADC measurement and its reproducibility, while the ROI sizes do not affect them. Two b values of (0, 800) s/mm(2) and ROI of 50 mm(2) are recommended for liver ADC measurement.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 31 条
  • [1] Measurement reproducibility of perfusion fraction and pseudodiffusion coefficient derived by intravoxel incoherent motion diffusion-weighted MR imaging in normal liver and metastases
    Andreou, A.
    Koh, D. M.
    Collins, D. J.
    Blackledge, M.
    Wallace, T.
    Leach, M. O.
    Orton, M. R.
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (02) : 428 - 434
  • [2] Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values
    Bilgili, Mirace Yasemin Karadeniz
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2066 - 2068
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique
    Bruegel, Melanie
    Holzapfel, Konstantin
    Gaa, Jochen
    Woertler, Klaus
    Waldt, Simone
    Kiefer, Berthold
    Stemmer, Alto
    Ganter, Carl
    Rummeny, Ernst J.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (03) : 477 - 485
  • [5] Reliability and validity of MR image lung volume measurement in fetuses with congenital diaphragmatic hernia and in vitro lung models
    Buesing, Karen A.
    Kilian, A. Kristina
    Schaible, Thomas
    Debus, Angelika
    Weiss, Christel
    Neff, K. Wolfgang
    [J]. RADIOLOGY, 2008, 246 (02) : 553 - 561
  • [6] Diffusion-weighted imaging of rectal cancer on repeatability and cancer characterization: an effect of b-value distribution study
    Chen, Luguang
    Shen, Fu
    Li, Zhihui
    Lu, Haidi
    Chen, Yukun
    Wang, Zhen
    Lu, Jianping
    [J]. CANCER IMAGING, 2018, 18
  • [7] Liver Diffusion-weighted MR Imaging: Reproducibility Comparison of ADC Measurements Obtained with Multiple Breath-hold, Free-breathing, Respiratory-triggered, and Navigator-triggered Techniques
    Chen, Xin
    Qin, Lei
    Pan, Dan
    Huang, Yanqi
    Yan, Lifen
    Wang, Guangyi
    Liu, Yubao
    Liang, Changhong
    Liu, Zaiyi
    [J]. RADIOLOGY, 2014, 271 (01) : 113 - 125
  • [8] MR-Diffusion Weighted Imaging of Healthy Liver Parenchyma: Repeatability and Reproducibility of Apparent Diffusion Coefficient Measurement
    Colagrande, Stefano
    Pasquinelli, Filippo
    Mazzoni, Lorenzo Nicola
    Belli, Giacomo
    Virgili, Gianni
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) : 912 - 920
  • [9] Agreement and Reproducibility of Apparent Diffusion Coefficient Measurements of Dual-b-Value and Multi-b-Value Diffusion-Weighted Magnetic Resonance Imaging at 1.5 Tesla in Phantom and in Soft Tissues of the Abdomen
    Corona-Villalobos, Celia Pamela
    Pan, Li
    Halappa, Vivek Gowdra
    Bonekamp, Susanne
    Lorenz, Christine H.
    Eng, John
    Kamel, Ihab R.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 46 - 51
  • [10] Field Strength and Diffusion Encoding Technique Affect the Apparent Diffusion Coefficient Measurements in Diffusion-Weighted Imaging of the Abdomen
    Dale, Brian M.
    Braithwaite, Adam C.
    Boll, Daniel T.
    Merkle, Elmar M.
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (02) : 104 - 108