Effect of early activation of cochlear implant on electrode impedance in pediatric population

被引:17
作者
Alhabib, Salman F. [1 ]
Abdelsamad, Yassin [2 ]
Yousef, Medhat [1 ,3 ]
Alzhrani, Farid [1 ]
Hagr, Abdulrahman [1 ]
机构
[1] King Saud Univ, Coll Med, King Abdullah Ear Specialist Ctr KAESC, Riyadh, Saudi Arabia
[2] MED El GmbH, Res Dept, Riyadh, Saudi Arabia
[3] Menoufia Univ Hosp, Fac Med, Audiol Unit, Menoufia, Egypt
关键词
One-day activation; Electrode impedance; Fibrosis; Minimal invasive cochlear implantation technique; SAFETY;
D O I
10.1016/j.ijporl.2020.110543
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: To assess the evolution of electrode impedance after the early fitting of audio processors (activation after one-day) and classical fitting (activation after one-month) over an up-to-one year after cochlear implant (CI) surgery. Methods: A retrospective cohort study on Fifty-two CI recipients divided into two groups. The study group included 24 recipients (40 ears) who underwent early fitting, whereas the control group contained 28 recipients (40 ears) who underwent classical fitting. The electrode impedance was recorded during the surgery, switch-on session and at one, three, six, and twelve-months after the surgery. Results: In the study group, electrode impedance values obtained intraoperatively and at switch-on and one, three, six, and twelve-months were 4.89, 3.69, 6.52, 6.24, 6.05, and 5.81 K Omega, respectively, and only the switch-on and one-month values were significantly different (p < 0.0001). In the control group, electrode impedance values obtained intraoperatively and at switch-on and one, three, six, and twelve-months were 4.71, 7.19, 6.40, 6.05, and 5.73 K Omega, respectively. Thus, the electrode impedance value at switch-on was 52.65% (p < 0.001) greater than it intraoperatively. For both groups, the electrode impedance value at twelve-months was significantly higher than the respective intraoperative values (study group: 18.6% higher, P = 0.04; control group: 21.65% higher, P = 0.0001). Conclusion: Electrode impedance was significantly lower in the study group compared to the control group until one month after the surgery. However, the electrode impedance at twelve-months after the CI was similar in both groups.
引用
收藏
页数:6
相关论文
共 27 条
[11]   Evolution of impedance field telemetry after one day of activation in cochlear implant recipients [J].
Hu, Hao-Chun ;
Chen, Joshua Kuang-Chao ;
Tsai, Chia-Mi ;
Chen, Hsing-Yi ;
Tung, Tao-Hsin ;
Li, Lieber Po-Hung .
PLOS ONE, 2017, 12 (03)
[12]   A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in Nucleus 24 cochlear implant users [J].
Hughes, ML ;
Werff, KRV ;
Brown, CJ ;
Abbas, PJ ;
Kelsay, DMR ;
Teagle, HFB ;
Lowder, MW .
EAR AND HEARING, 2001, 22 (06) :471-486
[13]   Flat-based fitting: the evaluation and usefulness of a new strategy-based fitting approach for cochlear implants [J].
Kurz, Anja ;
Hagen, Rudolf ;
van de Heyning, Paul ;
Mertens, Griet .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (11) :3239-3245
[14]   Surgical Techniques in Cochlear Implants [J].
Mangus, Brannon ;
Rivas, Alejandro ;
Tsai, Betty S. ;
Haynes, David S. ;
Roland, J. Thomas, Jr. .
OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2012, 45 (01) :69-+
[15]   Safety and Functional Results of Early Cochlear Implant Switch-On in Children [J].
Marsella, Pasquale ;
Scorpecci, Alessandro ;
Pacifico, Concettina ;
Resca, Alessandra ;
Vallarino, Maria Vittoria ;
Ingrosso, Angelo ;
Luchenti, Stefania .
OTOLOGY & NEUROTOLOGY, 2014, 35 (02) :277-282
[16]   Spontaneous increases in impedance following cochlear implantation: Suspected causes and management [J].
Neuburger, J. ;
Lenarz, T. ;
Lesinski-Schiedat, A. ;
Buechner, A. .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2009, 48 (05) :233-239
[17]   An in vitro model for investigating impedance changes with cell growth and electrical stimulation: implications for cochlear implants [J].
Newbold, Carrie ;
Richardson, Rachael ;
Huang, Christie Q. ;
Milojevic, Dusan ;
Cowan, Robert ;
Shepherd, Robert .
JOURNAL OF NEURAL ENGINEERING, 2004, 1 (04) :218-227
[18]  
Newbold Carrie, 2014, Cochlear Implants Int, V15, P191, DOI 10.1179/1754762813Y.0000000050
[19]   p A systematic review of the impact of adjusting input dynamic range (IDR), electrical threshold (T) level and rate of stimulation on speech perception ability in cochlear implant users [J].
Nunn, Terry B. ;
Jiang, Dan ;
Green, Tim ;
Boyle, Patrick J. ;
Vickers, Deborah A. .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2019, 58 (06) :317-325
[20]   The Long-Term Effects of Modified Electrode Surfaces and Intracochlear Corticosteroids on Postoperative Impedances in Cochlear Implant Patients [J].
Paasche, Gerrit ;
Tasche, Claudia ;
Stoever, Timo ;
Lesinski-Schiedat, Anke ;
Lenarz, Thomas .
OTOLOGY & NEUROTOLOGY, 2009, 30 (05) :592-598