Tear glucose dynamics in diabetes mellitus

被引:120
作者
Lane, Jennifer D.
Krumholz, David M.
Sack, Robert A.
Morris, Carol
机构
[1] SUNY State Coll Optometry, New York, NY 10036 USA
[2] CIBA Vis Corp, Duluth, GA USA
[3] So Cross Univ, Lismore, NSW, Australia
关键词
ambulatory monitoring; blood glucose; diabetes mellitus; noninvasive sampling; tear glucose;
D O I
10.1080/02713680600976552
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This study compares tear glucose dynamic differences between 121 diabetic and nondiabetic subjects after the administration of a carbohydrate load. A quantitative chromatographic analysis of tear glucose was used and the values correlated to blood glucose values. Diabetic and nondiabetic tear glucose mean values were 0.35 +/- 0.04 mmol/L and 0.16 +/- 0.03 mmol/L, respectively. Significant differences were observed among the subject groups in both the tear and capillary blood glucose values. A correlation between tear glucose and capillary blood glucose was observed. The concentration of glucose in the tear fluid changes proportionately with respect to capillary blood glucose after a carbohydrate challenge. Although it is possible to determine the diabetic status of a subject using tear glucose values alone, in the clinical setting this may not prove to be practical due to technical limitations.
引用
收藏
页码:895 / 901
页数:7
相关论文
共 35 条
[1]   Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid [J].
Alexeev, VL ;
Das, S ;
Finegold, DN ;
Asher, SA .
CLINICAL CHEMISTRY, 2004, 50 (12) :2353-2360
[2]   A glucose-sensing contact lens: from bench top to patient [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
CURRENT OPINION IN BIOTECHNOLOGY, 2005, 16 (01) :100-107
[3]   Ophthalmic glucose monitoring using disposable contact lenses - A review [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
JOURNAL OF FLUORESCENCE, 2004, 14 (05) :617-633
[4]   Ophthalmic glucose sensing: a novel monosaccharide sensing disposable and colorless contact lens [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
ANALYST, 2004, 129 (06) :516-521
[5]   Noninvasive continuous monitoring of physiological glucose using a monosaccharide-sensing contact lens [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :610-618
[6]  
Chen R, 1996, J CAPILLARY ELECTROP, V3, P243
[7]   Diabetic retinopathy Control of systemic factors preserves vision [J].
Colucciello, Michael .
POSTGRADUATE MEDICINE, 2004, 116 (01) :57-+
[8]  
Das B N, 1995, J Indian Med Assoc, V93, P127
[9]  
DAUM KM, 1982, INVEST OPHTH VIS SCI, V22, P509
[10]  
DAUM KM, 1984, ACTA OPHTHALMOL, V62, P472