A Comparison of Three Videolaryngoscopes: The Macintosh Laryngoscope Blade Reduces, but Does Not Replace, Routine Stylet Use for Intubation in Morbidly Obese Patients

被引:104
作者
Maassen, Ralph [1 ,2 ]
Lee, Ruben [3 ]
Hermans, Boukje [1 ,2 ]
Marcus, Marco [2 ]
van Zundert, Andre [1 ,4 ]
机构
[1] Catharina Hosp, Dept Anesthesiol, NL-5623 EJ Eindhoven, Netherlands
[2] Univ Hosp, Dept Anesthesiol, Maastricht, Netherlands
[3] Delft Univ Technol, Dept Biomech Engn Mech Mat & Maritime Engn, Delft, Netherlands
[4] Ghent Univ Hosp, Dept Anesthesiol, B-9000 Ghent, Belgium
关键词
EMERGENT ENDOTRACHEAL INTUBATION; SOFT PALATE PERFORATION; GLIDESCOPE(R) VIDEOLARYNGOSCOPE; TRACHEAL INTUBATION; MCGRATH(R) VIDEOLARYNGOSCOPE; VIDEO LARYNGOSCOPE; RUPTURE; INJURY; DIFFICULT;
D O I
10.1213/ANE.0b013e3181b7303a
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Many manufacturers are producing videolaryngoscopes (VLSs) with differing specifications, user interfaces, and geometry. It is clinically relevant to know the relative performance of the blades. Visualization of the glottis and intubation are often problematic in (extremely) obese patients, and the new video technology may offer better functionality and performance. Although many tracheal intubations with direct laryngoscopy are performed with an unstyletted endotracheal tube, it is recommended to use a stylet for intubation using videolaryngoscopy. In this study, we compared 3 VLSs in morbidly obese patients undergoing intubation for elective surgery and tested whether it is feasible to intubate the tracheas of morbidly obese patients without using a stylet. METHODS: One hundred fifty consecutive adult morbidly obese patients (body mass index >35 kg/m(2)) were randomly selected to receive one of 3 VLSs: GlideScope (R), Storz (R) V-Mac (TM), and McGrath (R). Direct laryngoscopy scored the best possible view of the glottis; subsequently, the respective VLS was used, and the patient's trachea was intubated. Common preprocedural (e.g., Mallampati grade) and intraprocedural (Cormack-Lehane grade) metrics of intubation difficulty were measured, as well as the dependent variables of intubation time, number of attempts, and subjective difficulty. RESULTS: All 3 VLSs tested offered an equal or better view of the glottis compared with traditional direct laryngoscopy. The number of attempts necessary to intubate the trachea differed significantly among VLSs (average 2.6 +/- 1.0 attempts for the GlideScope, 1.4 +/- 0.7 for the Storz, and 2.9 +/- 0.9 for the McGrath VLS). The average intubation times were 33 +/- 18 s for the GlideScope, 17 +/- 9 s for the Storz, and 41 +/- 25 s for the McGrath VLS. CONCLUSIONS: In this study, the VLS with the Macintosh blade (Storz VLS) had a better overall satisfaction score, intubation time, number of intubation attempts, and necessity of extra adjuncts, compared with the 2 other tested devices. (Anesth Analg 2009;109:1560-5)
引用
收藏
页码:1560 / 1565
页数:6
相关论文
共 25 条
[1]   Critical hemoglobin desaturation will occur before return to an unparalyzed state following 1 mg/kg intravenous succinylcholine [J].
Benumof, JL ;
Dagg, R ;
Benumof, R .
ANESTHESIOLOGY, 1997, 87 (04) :979-982
[2]  
Besmer I, 2001, ANAESTHESIST, V50, P167, DOI 10.1007/s001010050984
[3]   A case of tracheal injury after emergent endotracheal intubation: A review of the literature and causalities [J].
Chen, EH ;
Logman, ZM ;
Glass, PSA ;
Bilfinger, TV .
ANESTHESIA AND ANALGESIA, 2001, 93 (05) :1270-1271
[4]   Another complication associated with videolaryngoscopy [J].
Choo, Michael K. F. ;
Yeo, Vincent S. T. ;
See, Jee Jian .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (04) :322-324
[5]   Complications associated with the use of the GlideScope® videolaryngoscope [J].
Cooper, Richard M. .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (01) :54-57
[6]   Perforation of the soft palate using the GlideScope® videolaryngoscope [J].
Cross, Paul ;
Cytryn, Jacalyn ;
Cheng, Kenneth K. .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (07) :588-589
[7]   The GlideScope® video laryngoscope [J].
Doyle, DJ .
ANAESTHESIA, 2005, 60 (04) :414-415
[8]   Tracheal rupture complicating emergent endotracheal intubation [J].
Fan, CM ;
Ko, PCI ;
Tsai, KC ;
Chiang, WC ;
Chang, MC ;
Chen, WJ ;
Yuan, A .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2004, 22 (04) :289-293
[9]   The importance of increased neck circumference to intubation difficulties in obese patients [J].
Gonzalez, Helene ;
Minville, Vincent ;
Delanoue, Khedija ;
Mazerolles, Michel ;
Concina, Dominique ;
Fourcade, Olivier .
ANESTHESIA AND ANALGESIA, 2008, 106 (04) :1132-1136
[10]   Pharyngeal injury related to GlideScope videolaryngoscope [J].
Hirabayashi, Yoshihiro .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2007, 137 (01) :175-176