Determination of Pd(II) using an antimony film coated on a screen-printed electrode by adsorptive stripping voltammetry

被引:16
作者
Perez-Rafols, Clara [1 ]
Trechera, Pedro [1 ]
Serrano, Nuria [1 ]
Diaz-Cruz, Jose Manuel [1 ]
Arino, Cristina [1 ]
Esteban, Miguel [1 ]
机构
[1] Univ Barcelona, Fac Quim, Dept Engn Quim & Quim Analit, Marti & Franques 1-11, E-08028 Barcelona, Spain
关键词
Palladium; Antimony film electrode; Adsorptive stripping voltammetry; Screen-printed electrode; PLATINUM-GROUP METALS; KINETIC-SPECTROPHOTOMETRIC DETERMINATION; BISMUTH-FILM; CARBON ELECTRODE; PALLADIUM; PRECONCENTRATION; SAMPLES; WATER; IONS; ELECTROANALYSIS;
D O I
10.1016/j.talanta.2017.01.084
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of an antimony film coated on a screen-printed carbon electrode (ex-situ SbSPCE) is proposed for the determination of Pd(II) at ppb levels in natural samples by adsorptive stripping voltammetry using dimethylglyoxime as chelating agent. Ex-situ SbSPCE produces a better analytical performance as compared to a commercially sputtered bismuth screen-printed electrode (BispSPE). The detection and quantification limits were 2.7 and 9.0 mu g L-1 respectively with a good linear behaviour in the wide examined concentration range (from 1 mu g L-1 up to 100.0 mu g L-1, R-2=0.998). The proposed ex-situ SbSPCE showed an excellent repeatability with a relative standard deviation of 0.5% for ten successive measurements and a very good reproducibility (1.6% for three different ex-situ SbSPCE units within series of ten repetitive assays). Moreover, the ex-situ SbSPCE was successfully applied for the determination of low concentration levels of Pd(II) in spiked tap water with a very high reproducibility (0.2%) and providing equivalent results to those achieved by ICP-MS measurements.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 29 条
  • [1] Ex-situ Antimony Screen-printed Carbon Electrode for Voltammetric Determination of Ni(II)-ions in Wastewater
    Barcelo, Cristian
    Serrano, Nuria
    Arino, Cristina
    Manuel Diaz-Cruz, Jose
    Esteban, Miquel
    [J]. ELECTROANALYSIS, 2016, 28 (03) : 640 - 644
  • [2] Screen-printed electrodes for environmental monitoring of heavy metal ions: a review
    Barton, John
    Gonzalez Garcia, Maria Begona
    Hernandez Santos, David
    Fanjul-Bolado, Pablo
    Ribotti, Alberto
    McCaul, Margaret
    Diamond, Dermot
    Magni, Paolo
    [J]. MICROCHIMICA ACTA, 2016, 183 (02) : 503 - 517
  • [3] The Silver Amalgam Film Electrode in Adsorptive Stripping Voltammetric Determination of Palladium(II) as Its Dimethyldioxime Complex
    Bobrowski, Andrzej
    Gawlicki, Marek
    Kapturski, Pawel
    Mirceski, Valentin
    Spasovski, Filip
    Zarebski, Jerzy
    [J]. ELECTROANALYSIS, 2009, 21 (01) : 36 - 40
  • [4] On-line preconcentration of palladium(II) using a microcolumn packed with a chelating resin, and its subsequent determination by graphite furnace atomic absorption spectrometry
    Bosch Ojeda, Catalina
    Sanchez Rojas, Fuensanta
    Cano Pavon, Jose Manuel
    [J]. MICROCHIMICA ACTA, 2007, 158 (1-2) : 103 - 110
  • [5] Bismuth-film electrodes: recent developments and potentialities for electroanalysis
    Economou, A
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) : 334 - 340
  • [6] Kinetic-spectrophotometric determination of palladium in hydrogenation catalyst by its catalytic effect on the oxidation of pyrogallol red by hydrogen peroxide
    Ensafi, AA
    Keyvanfard, M
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (08) : 1567 - 1572
  • [7] Performance of ammonium dihydrogenphosphate-palladium nitrate by graphite furnace atomic absorption spectrophotometer with Zeeman correction for optimized urinary manganese determination in a biological laboratory
    Guillard, Olivier
    Favreau, Frederic
    Fauconneau, Bernard
    Chantreau, Aline
    Pineau, Alain
    [J]. ANALYTICAL BIOCHEMISTRY, 2007, 362 (02) : 284 - 286
  • [8] Disposable Screen Printed Electrochemical Sensors: Tools for Environmental Monitoring
    Hayat, Akhtar
    Marty, Jean Louis
    [J]. SENSORS, 2014, 14 (06): : 10432 - 10453
  • [9] Application of thiophene-2-carbaldehyde-modified mesoporous silica as a new sorbent for separation and preconcentration of palladium prior to inductively coupled plasma atomic emission spectrometric determination
    Jamali, Mohammad Reza
    Assadi, Yaghoub
    Shemirani, Farzaneh
    Salavati-Niasari, Masoud
    [J]. TALANTA, 2007, 71 (04) : 1524 - 1529
  • [10] Keller D., 2002, ENV HLTH CRIT