On analysis and redesign of bolted L-flanged connections

被引:7
|
作者
Pedersen, Niels Leergaard [1 ]
机构
[1] Tech Univ Denmark, Dept Mech Engn, Solid Mech, Nils Koppels Alle,Bldg 404, DK-2800 Lyngby, Denmark
关键词
L-flange; bolt; eccentric; contact; design; FE; PLATE CONTACT ASSEMBLIES; STIFFNESS ANALYSIS; DESIGN;
D O I
10.1002/we.2080
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In wind turbine towers, the preferred design is circular tubes that are connected by a bolted flange joint. The design is typically that of an L-flange resulting in an eccentrically loaded bolted connection. The eccentricity results in a non-linear relationship between external load on the tower and the tensile force in the bolt. In the literature and also in standards, different models are presented for this important non-linear response. In the present paper, a simplified expression for the non-linear force response is presented based on finite element calculations using contact analysis. The L-flange connection is in essence a bad design because it leads to a non-optimal ratio between external force and bolt force. Furthermore, bolt bending results in an even higher bolt stress resulting in a reduction of strength. The present paper presents simple modifications of the L-flange design that considerably improves the connection strength. Copyright (c) 2017 John Wiley & Sons, Ltd.
引用
收藏
页码:1069 / 1082
页数:14
相关论文
共 50 条
  • [31] Analysis of Bolted Flanged Panel Joint for GRP Sectional Tanks
    Radhakrishnan, S. M.
    Dyer, B.
    Kashtalyan, M.
    Akisanya, A. R.
    Guz, I.
    Wilkinson, C.
    APPLIED COMPOSITE MATERIALS, 2014, 21 (01) : 247 - 261
  • [32] Analysis of Bolted Flanged Panel Joint for GRP Sectional Tanks
    S. M. Radhakrishnan
    B. Dyer
    M. Kashtalyan
    A. R. Akisanya
    I. Guz
    C. Wilkinson
    Applied Composite Materials, 2014, 21 : 247 - 261
  • [33] CHARACTERIZATION OF SEALING BEHAVIOR OF GASKETS FOR THE LEAK RATE BASED DESIGN OF GASKETED BOLTED FLANGED CONNECTIONS
    Kobayashi, Takashi
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 2, 2009, : 107 - 114
  • [34] Modeling and Analysis of a Bolted Flanged Pipe Joint Subjected to Bending
    Choudhury, Mahbuboor Rahman
    Quayyum, Shahriar
    Amanat, Khan Mahmud
    COMPUTATIONAL ENGINEERING IN SYSTEMS APPLICATIONS, 2008, : 256 - 261
  • [35] FLANGED PIPE CONNECTIONS
    GAUDE, EC
    PLANT ENGINEERING, 1978, 32 (10) : 143 - 147
  • [36] ANALYSIS OF BOLTED CONNECTIONS SUBJECT TO PRYING
    MUZEAU, JP
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1978, 104 (09): : 1545 - 1545
  • [37] ANALYSIS OF BOLTED CONNECTIONS SUBJECT TO PRYING
    KRISHNAMURTHY, N
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1978, 104 (12): : 1928 - 1930
  • [38] ANALYSIS OF BOLTED CONNECTIONS SUBJECT TO PRYING
    AGERSKOV, H
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1977, 103 (11): : 2145 - 2163
  • [39] Reliability analysis of bolted wood connections
    Bulleit, WM
    Decator, DB
    PROBABILISTIC MECHANICS & STRUCTURAL RELIABILITY: PROCEEDINGS OF THE SEVENTH SPECIALTY CONFERENCE, 1996, : 326 - 329
  • [40] Analytical Method of Gasket Stress on Bolted Flanged Connections in Consideration of External Bending Moments and Elements Creep
    Liu, Lin
    Gu, Boqin
    2009 INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, VOL II, 2009, : 750 - 753