Femoral Anteversion in THA and its Lack of Correlation with Native Acetabular Anteversion

被引:60
作者
Bargar, William L.
Jamali, Amir A. [1 ]
Nejad, Amir H. [2 ]
机构
[1] UC Davis Med Ctr, Davis, CA USA
[2] Univ Calif Davis, Dept Orthopaed, Davis, CA USA
关键词
TOTAL HIP-REPLACEMENT; SYSTEM; MOTION; RANGE;
D O I
10.1007/s11999-009-1040-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Several studies support the concept that, for optimum range of motion in THA, the combined femoral and acetabular anteversion should be some constant or fall within some "safe zone.'' When using a cementless femoral component, the surgeon has little control of the anteversion of the component since it is dictated by native femoral anteversion. Given this constraint, we asked whether the surgeon should use the native anteversion of the acetabulum as a target for implant position in THA. Forty-six patients scheduled for primary THA underwent CT scanning and preoperative planning using a computer workstation. The native acetabular anteversion and the native femoral anteversion were measured. Prosthetic femoral anteversion was measured on the workstation by three-dimensional templating of a straight-stemmed tapered implant. The mean of the sum of the native acetabular anteversion and native femoral anteversion was 28.9 degrees; however, 17% varied by 10 degrees to 15 degrees and 11% by more than 15 degrees. The mean of native femoral anteversion and prosthetic femoral anteversion was 13.8 degrees (range, -6.1 degrees-32.7 degrees) and 22.5 degrees (range, 1 degrees-39 degrees), respectively. Based on our data, we believe the surgeon should not use the native acetabular anteversion as a target for positioning the acetabular component.
引用
收藏
页码:527 / 532
页数:6
相关论文
共 13 条
  • [1] Bargar WL, 1998, CLIN ORTHOP RELAT R, P82
  • [2] Anteroposterior pelvic radiographs to assess acetabular retroversion: High validity of the "cross-over-sign"
    Jamali, Amir A.
    Mladenov, Kiril
    Meyer, Dominik C.
    Martinez, Alberto
    Beck, Martin
    Ganz, Reinhold
    Leunig, Michael
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2007, 25 (06) : 758 - 765
  • [3] Linear and angular measurements of computer-generated models: Are they accurate, valid, and reliable?
    Jamali, Amir A.
    Deuel, Christopher
    Perreira, Aimee
    Salgad, Christopher J.
    Hunter, John C.
    Strong, E. Bradley
    [J]. COMPUTER AIDED SURGERY, 2007, 12 (05) : 278 - 285
  • [4] 3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC® system
    Lee, Yeon Soo
    SH, Oh
    Seon, Jong Keun
    Song, Eun Kyoo
    Yoon, Taek Rim
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (10) : 895 - 906
  • [5] Lucas D., 1994, J ORTHOP TECH, V2, P59
  • [6] Impingement with total hip replacement
    Malik, Aamer
    Maheshwari, Aditya
    Dorr, Lawrence D.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (08) : 1832 - 1842
  • [7] THE DEFINITION AND MEASUREMENT OF ACETABULAR ORIENTATION
    MURRAY, DW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02): : 228 - 232
  • [8] Variations in acetabular anatomy with reference to total hip replacement
    Murtha, P. E.
    Hafez, M. A.
    Jaramaz, B.
    DiGioia, A. M., III
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (03): : 308 - 313
  • [9] Computed tomography analysis of acetabular anteversion and abduction
    Stem, ES
    O'Connor, MI
    Kransdorf, MJ
    Crook, J
    [J]. SKELETAL RADIOLOGY, 2006, 35 (06) : 385 - 389
  • [10] A comparison of alternative methods of measuring femoral anteversion
    Sugano, N
    Noble, PC
    Kamaric, E
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (04) : 610 - 614