Preliminary evaluation of cone beam computed tomography in three-dimensional cephalometry for clinical application

被引:12
作者
Li, Na [1 ]
Hu, Bo [2 ]
Mi, Fanglin [1 ]
Song, Jinlin [2 ]
机构
[1] North Sichuan Med Coll, Affiliated Hosp, Dept Stomatol, Nanchong 637000, Sichuan, Peoples R China
[2] Chongqing Med Univ, Stomatol Hosp, Dept Orthodont, 426 Songshibei Rd, Chongqing 401147, Peoples R China
关键词
cone-beam computed tomography; orthodontics; cephalometry; LANDMARK IDENTIFICATION; RELIABILITY; ACCURACY; IMAGES;
D O I
10.3892/etm.2017.4278
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The present study was conducted to evaluate the three-dimensional (3D) cephalometry accuracy of cone-beam computed tomography (CBCT). A total of 40 newly diagnosed orthodontic patients (including 18 males and 22 females; age range, 12-18 years) were subjected to CBCT scanning and X-ray imaging in order to obtain lateral cephalograms. The 3D CBCT cephalograms were reconstructed and measured with in vivo 5.1 software, and compared with the results from the conventional 2D lateral cephalograms. Measurements in the two images were performed twice using the Steiner and Tweed standards and a single analyzer paired t-test was used to analyze the differences between the two cephalometric methods. The results indicated that the two methods showed significant differences in all 12 angle and 5 linear measurements (P< 0.05). These findings indicated that CBCT is a more accurate technique compared with the conventional 2D method. In conclusion, CBCT may provide diagnostic and treatment information for maxillofacial deformities by using fast computer-aided analysis platform.
引用
收藏
页码:2451 / 2455
页数:5
相关论文
共 25 条
[1]  
Arnheiter C., 2006, ORAL RADIOL, V22, P80, DOI DOI 10.1007/S11282-006-0055-6
[2]  
AYi-jiang MiCong-bo, 2011, J CLIN REHABILITATIV, V26, P4869
[3]   Reliability and accuracy of cone-beam computed tomography dental measurements [J].
Baumgaertel, Sebastian ;
Palomo, J. Martin ;
Palomo, Leena ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :19-25
[4]   RELIABILITY OF HEAD FILM MEASUREMENTS .1. LANDMARK IDENTIFICATION [J].
BAUMRIND, S ;
FRANTZ, RC .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (02) :111-&
[5]   THE GEOMETRY OF 3-DIMENSIONAL MEASUREMENT FROM PAIRED CO-PLANAR X-RAY IMAGES [J].
BAUMRIND, S ;
MOFFITT, FH ;
CURRY, S .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1983, 84 (04) :313-322
[6]   Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature [J].
De Vos, W. ;
Casselman, J. ;
Swennen, G. R. J. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (06) :609-625
[7]  
Feng Q, 2006, KOU QIANG CAI LIAO Q, V15, P140
[8]   Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans [J].
Gribel, Bruno Frazao ;
Gribel, Marcos Nadler ;
Frazao, Diogo Campos ;
McNamara, James A., Jr. ;
Manzi, Flavio Ricardo .
ANGLE ORTHODONTIST, 2011, 81 (01) :26-35
[9]  
Holly Broadbent B., 1931, Angle Oathod, V1, P45, DOI DOI 10.1043/0003-3219(1931)001<0045:ANXTAI>2.0.CO
[10]  
2