Influence of the methodology and evaluation criteria on determining microleakage in dentin-restorative interfaces

被引:21
作者
Amarante de Camargo, Denise Arliane
Coelho Sinhoreti, Mario Alexandre
Correr-Sobrinho, Lourenco
de Sousa Neto, Manoel Damiao
Consani, Simonides
机构
[1] Univ Estadual Campinas, UNICAMP, Piracicaba Sch Dent, Dept Restorat Dent, BR-13414903 Piracicaba, SP, Brazil
[2] Vale Itajai Univ, UNIVALI, Dept Restorat Dent, Itajai, Brazil
[3] Univ Ribeirao Preto, UNAERP, Fac Dent, Dept Endodont, Ribeirao Preto, SP, Brazil
关键词
dye; microleakage; composite; methodology;
D O I
10.1007/s00784-006-0061-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study compared microleakage along the dentin-restorative interface using a spectrophotometer protocol and two conventional single-surface methods (scores and percentages), using an organic dye (0.5% buffered methylene blue) or a tracer (50% silver nitrate). Occluso-proximal preparations with gingival margins in dentin were made in 40 human teeth. The teeth were divided into four groups (n=10) according to the solution dyes and adhesive system used: group 1, single bond/methylene blue; group 2, single bond/silver nitrate; group 3, Clearfil SE Bond/methylene blue; and group 4, Clearfil SE Bond/silver nitrate. The dye penetration measurements were made in all groups, using scores and percentages. Groups 1 and 3 were also assessed by UV spectrophotometer. For percentage measurement, the data were submitted to ANOVA and Tukey's test. For the material factor, there was a statistically significant difference between groups 1 and 3. For the dye factor, there was a statistically significant difference between groups 3 and 4. The score results were submitted to Kruskall-Wallis test and showed differences between groups 1 and 3 and groups 2 and 3. For spectrophotometer measurement, no significant difference was observed between groups 1 and 3. The results of dye penetration suggest that there was a difference between dyes and measurement methods, and this should change the interpretation of microleakage tests.
引用
收藏
页码:317 / 323
页数:7
相关论文
共 32 条
  • [1] Alani AH, 1997, OPER DENT, V22, P173
  • [2] Association of photoactivation methods and low modulus liners on marginal adaptation of composite restorations
    Alonso, RCB
    Cunha, LG
    Correr, GM
    De Goes, MF
    Correr-Sobrinho, L
    Puppin-Rontani, RM
    Sinhoreti, MAC
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2004, 62 (06) : 298 - 304
  • [3] Arrais Cesar Augusto Galvao, 2002, Pesqui Odontol Bras, V16, P115
  • [4] CAMARGO DA, 2002, J DENT RES, V81
  • [5] CAMARGO DA, 2002, BRAZ J ORAL SCI, V1, P84
  • [6] A challenge to the conventional wisdom that simultaneous etching and resin infiltration always occurs in self-etch adhesives
    Carvalho, RM
    Chersoni, S
    Frankenberger, R
    Pashley, DH
    Prati, C
    Tay, FR
    [J]. BIOMATERIALS, 2005, 26 (09) : 1035 - 1042
  • [7] Microleakage in class II composite resin restorations: application of a clearing protocol.
    Federlin M.
    Thonemann B.
    Hiller K.-A.
    Fertig C.
    Schmalz G.
    [J]. Clinical Oral Investigations, 2002, 6 (2) : 84 - 91
  • [8] Dentine permeability and tracer tests
    Gale, MS
    Darvell, BW
    [J]. JOURNAL OF DENTISTRY, 1999, 27 (01) : 1 - 11
  • [9] GENNARO AR, 2000, REMINGTON SCI PRACTI, P1272