Application of 99m Tc-UBI 29-41 scintigraphy in knee periprosthetic infection diagnosis

被引:2
作者
Kiamanesh, Zahra [1 ]
Ayati, Narjess [1 ]
Alavi, Royasadat [1 ]
Gharehdaghi, Mohammad [2 ]
Aryana, Kamran [1 ]
机构
[1] Mashhad Univ Med Sci, Nucl Med Res Ctr, Mashhad, Razavi Khorasan, Iran
[2] Mashhad Univ Med Sci, Res Ctr Orthoped Surg, Mashhad, Razavi Khorasan, Iran
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2019年 / 58卷 / 04期
关键词
Total knee arthroplasty; (99m) TC-UBI scintigraphy; periprosthetic infection; prosthetic loosening; PEPTIDE UBIQUICIDIN 29-41; ANTIMICROBIAL PEPTIDE; NUCLEAR-MEDICINE; TC-99M-UBIQUICIDIN SCINTIGRAPHY; CLINICAL UTILITY; SCAN; OSTEOMYELITIS; ARTHROPLASTY; PROSTHESIS;
D O I
10.1055/a-0941-3317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim In recent years, the use of total knee arthroplasty (TKA) is considered a safe and cost-effective orthopedic procedure for alleviating the chronic pain and treatment of progressive osteoarthritis. This procedure may have some complications including periprosthetic infection as the most serious and aseptic loosening as the most common one. Differentiating between these entities is important because each has a different therapeutic approach. This study was conducted to investigate the ability of (99m) TC-UBI scan to distinguish septic from aseptic loosening in a painful knee prosthesis. Methods 34 patients with painful knee prostheses were included. The (99m) TC-UBI scan was done immediately after IV administration of (99m) TC-UBI in early dynamic and 30-minute static images. Time-activity curve (TAC) was drawn for all patients and target to non-target ratio (T/NT) was calculated on 30-minute images. The final diagnosis was confirmed by surgical findings, microbiologic culture results or active clinical follow up. Results Using TAC analysis, 24 (99m) TC-UBI scans were considered negative and 10 positive for an infectious process. Sensitivity, specificity, negative and positive predictive values were 56 %, 80 %, 83 %, and 50 %, respectively. T/NT ratio analysis on 30-minute static images demonstrated 9 positive and 25 negative patterns, with a cut off value of 1.83 for the T/NT ratio. The sensitivity, specificity, negative and positive predictive values, and accuracy of this test modality were all 100 %. Conclusions Our findings show (99m) Tc-UBI scan is an excellent clinical diagnostic test for differentiating septic from aseptic loosening of the knee prostheses with perfect sensitivity and specificity. Highly accurate results were obtained only 30 minutes after injection.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 26 条
[1]  
Akhtar MS, 2005, J NUCL MED, V46, P567
[2]   An imaging analysis of 99mTc-UBI (29-41) uptake in S-aureus infected thighs of rabbits on ciprofloxacin treatment [J].
Akhtar, Muhammad Saeed ;
Khan, Muhammad Ejaz ;
Khan, Bashar ;
Irfanullah, Javaid ;
Afzal, Muhammad Shahzad ;
Khan, Muhammad Aleem ;
Nadeem, Muhammad Afzal ;
Jehangir, Mustansar ;
Imran, Muhammad Babar .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) :1056-1064
[3]   99mTc-labeled ubiquicidin scintigraphy A promising method in hip prosthesis infection diagnosis [J].
Aryana, K. ;
Hootkani, A. ;
Sadeghi, R. ;
Davoudi, Y. ;
Naderinasab, M. ;
Erfani, M. ;
Ayati, N. .
NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2012, 51 (04) :133-139
[4]   Diagnostic value of 99mTc-ubiquicidin scintigraphy for osteomyelitis and comparisons with 99mTc-methylene diphosphonate scintigraphy and magnetic resonance imaging [J].
Assadi, Majid ;
Vahdat, Katayoun ;
Nabipour, Iraj ;
Sehhat, Mohammad Reza ;
Hadavand, Fahimeh ;
Javadi, Hamid ;
Tavakoli, Alireza ;
Saberifard, Jamshid ;
Kalantarhormozi, Mohammad Reza ;
Zakani, Alireza ;
Eftekhari, Mohammad .
NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (08) :716-723
[5]   Diagnostic value of 99mTc-ubiquicidin scintigraphy in differentiation between osteomyelitis and bone tumors [J].
Ayati, Narjess ;
Norouzi, Mohammad ;
Sadeghi, Ramin ;
Erfani, Mostafa ;
Gharedaghi, Mohammad ;
Aryana, Kamran .
NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (11) :885-890
[6]  
Beiki D, 2013, IRAN J PHARM RES, V12, P347
[7]  
Brammen L, 2015, HELL J NUCL MED, V18, P95
[8]  
Brouwer CPJM, 2010, Q J NUCL MED MOL IM, V54, P442
[9]  
Chopra A., 2004, MOL IMAGING CONTRAST
[10]   Total Knee Arthroplasty Volume, Utilization, and Outcomes Among Medicare Beneficiaries, 1991-2010 [J].
Cram, Peter ;
Lu, Xin ;
Kates, Stephen L. ;
Singh, Jasvinder A. ;
Li, Yue ;
Wolf, Brian R. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 308 (12) :1227-1236