Formaldehyde-releasers in cosmetics: relationship to formaldehyde contact allergy Part 1. Characterization, frequency and relevance of sensitization, and frequency of use in cosmetics

被引:80
作者
de Groot, Anton C. [1 ]
White, Ian R. [2 ]
Flyvholm, Mari-Ann [3 ]
Lensen, Gerda [1 ]
Coenraads, Pieter-Jan [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Dermatol, NL-9700 RB Groningen, Netherlands
[2] St Thomas Hosp, St Johns Inst Dermatol, London, England
[3] Natl Res Ctr Working Environm, Copenhagen, Denmark
关键词
2-bromo-2-nitropropane-1,3-diol; 5-bromo-5-nitro-1,3-dioxane; benzylhemiformal; cosmetics; diazolidinyl urea; DMDM hydantoin; formaldehyde; formaldehyde-releaser; imidazolidinyl urea; quaternium-15; sodium hydroxymethylglycinate; toiletries; EUROPEAN STANDARD SERIES; PATCH TEST REACTIONS; DERMATITIS GROUP; DMDM HYDANTOIN; METALWORKING FLUIDS; PRESERVATIVES; SENSITIVITY; UREA; IMIDAZOLIDINYLUREA; ANTIMICROBIALS;
D O I
10.1111/j.1600-0536.2009.01615.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
In this part of a series of review articles on formaldehyde-releasers and their relationship to formaldehyde contact allergy, formaldehyde-releasers in cosmetics are discussed. In this first part of the article, key data are presented including frequency of sensitization and of their use in cosmetics. In Europe, low frequencies of sensitization have been observed to all releasers: 2-bromo-2-nitropropane-1,3-diol 0.4-1.2%, diazolidinyl urea 0.5-1.4%, imidazolidinyl urea 0.3-1.4%, quaternium-15 0.6-1.9% (for DMDM hydantoin no recent data are available). All releasers score (far) higher prevalences in the USA; the possible explanations for this are discussed. The relevance of positive patch test reactions has been insufficiently investigated. In the USA, approximately 20% of cosmetics and personal care products (stay-on products: 17%, rinse-off products 27%) contain a formaldehyde-releaser. The use of quaternium-15 is decreasing. For Europe, there are no comparable recent data available. In the second part of the article, the patch test relationship of the releasers in cosmetics to formaldehyde contact allergy will be reviewed and it will be assessed whether products preserved with formaldehyde-releasers may contain enough free formaldehyde to pose a threat to individuals who have contact allergy to formaldehyde.
引用
收藏
页码:2 / 17
页数:16
相关论文
共 62 条
  • [41] Marks James G Jr, 2003, Am J Contact Dermat, V14, P59
  • [42] North American Contact Dermatitis Group patch-test results, 1996-1998
    Marks, JG
    Belsito, DV
    DeLeo, VA
    Fowler, JF
    Fransway, AF
    Maibach, HI
    Mathias, CGT
    Pratt, MD
    Rietschel, RL
    Sherertz, EF
    Storrs, FJ
    Taylor, JS
    [J]. ARCHIVES OF DERMATOLOGY, 2000, 136 (02) : 272 - 273
  • [43] North American Contact Dermatitis Group patch test results for the detection of delayed-type hypersensitivity to topical allergens
    Marks, JG
    Belsito, DV
    DeLeo, VA
    Fowler, JF
    Fransway, AF
    Maibach, HI
    Mathias, CGT
    Nethercott, JR
    Rietschel, RL
    Sherertz, EF
    Storrs, FJ
    Taylor, JS
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1998, 38 (06) : 911 - 918
  • [44] Marks JG., 1995, Am J Contact Dermatitis, V6, P160, DOI DOI 10.1016/1046-199X(95)90122-1
  • [45] PARKER LU, 1991, AM J CONTACT DERMAT, V2, P231
  • [46] FREQUENCY OF SENSITIZATION TO 13 COMMON PRESERVATIVES IN SWITZERLAND
    PERRENOUD, D
    BIRCHER, A
    HUNZIKER, T
    SUTER, H
    BRUCKNERTUDERMAN, L
    STAGER, J
    THURLIMANN, W
    SCHMID, P
    SUARD, A
    HUNZIKER, N
    [J]. CONTACT DERMATITIS, 1994, 30 (05) : 276 - 279
  • [47] CONTACT SENSITIVITY TO DIAZOLIDINYL UREA (GERMALL-II)
    PERRET, CM
    HAPPLE, R
    [J]. ARCHIVES OF DERMATOLOGICAL RESEARCH, 1989, 281 (01) : 57 - 59
  • [48] Pratt Melanie D, 2004, Dermatitis, V15, P176, DOI 10.2310/6620.2004.04038
  • [49] Analytical control of preservative labelling on skin creams
    Rastogi, SC
    [J]. CONTACT DERMATITIS, 2000, 43 (06) : 339 - 343
  • [50] RASTOGI SC, 1992, CONTACT DERMATITIS, V27, P235