Simple method for computing scattered radiation in breast tomosynthesis

被引:10
作者
Diaz, Oliver [1 ,2 ]
Elangovan, Premkumar [3 ]
Young, Kenneth C. [3 ,4 ]
Wells, Kevin [1 ]
Dance, David R. [3 ,4 ]
机构
[1] CVSSP Univ Surrey, Guildford GU2 7XH, Surrey, England
[2] VICOROB Univ Girona, Girona 17071, Spain
[3] NCCPM Royal Surrey Cty Hosp, Guildford GU2 7XX, Surrey, England
[4] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
anthropomorphic breast models; DBT; Monte Carlo simulations; scattered radiation; SPR; virtual clinical trial; MONTE-CARLO-SIMULATION; DIGITAL RADIOGRAPHY; MAMMOGRAPHY; CONTRAST; FIELD; PERFORMANCE; VALIDATION; PHANTOM; MODELS; GRIDS;
D O I
10.1002/mp.13760
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Virtual clinical trials (VCT) are a powerful imaging tool that can be used to investigate digital breast tomosynthesis (DBT) technology. In this work, a fast and simple method is proposed to estimate the two-dimensional distribution of scattered radiation which is needed when simulating DBT geometries in VCTs. Methods Monte Carlo simulations are used to precalculate scatter-to-primary ratio (SPR) for a range of low-resolution homogeneous phantoms. The resulting values can be used to estimate the two-dimensional (2D) distribution of scattered radiation arising from inhomogeneous anthropomorphic phantoms used in VCTs. The method has been validated by comparing the values of the scatter thus obtained against the results of direct Monte Carlo simulation for three different types of inhomogeneous anthropomorphic phantoms. Results Differences between the proposed scatter field estimation method and the ground truth data for the OPTIMAM phantom had an average modulus and standard deviation of over the projected breast area of 2.4 +/- 0.9% (minimum -17.0%, maximum 27.7%). The corresponding values for the University of Pennsylvania and Duke University breast phantoms were 1.8 +/- 0.1% (minimum -8.7%, maximum 8.0%) and 5.1 +/- 0.1% (minimum -16.2%, maximum 7.4%), respectively. Conclusions The proposed method, which has been validated using three of the most common breast models, is a useful tool for accurately estimating scattered radiation in VCT schemes used to study current designs of DBT system.
引用
收藏
页码:4826 / 4836
页数:11
相关论文
共 50 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[3]  
Badawy A, 2018, J COMPUT SOC SCI, V1, P453, DOI [10.1007/s42001-018-0015-z, 10.1001/jamanetworkopen.2018.5474]
[4]  
Bakic PR, P SPIE
[5]   Development and characterization of an anthropomorphic breast software phantom based upon region-growing algorithm [J].
Bakic, Predrag R. ;
Zhang, Cuiping ;
Maidment, Andrew D. A. .
MEDICAL PHYSICS, 2011, 38 (06) :3165-3176
[6]   AAPM TUTORIAL - CONTRAST AND SCATTER IN X-RAY-IMAGING [J].
BARNES, GT .
RADIOGRAPHICS, 1991, 11 (02) :307-323
[7]  
Barufaldi B, P SPIE
[8]   Scatter/primary in mammography: Monte Carlo validation [J].
Boone, JM ;
Cooper, VN .
MEDICAL PHYSICS, 2000, 27 (08) :1818-1831
[9]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[10]   STUDIES OF PERFORMANCE OF ANTISCATTER GRIDS IN DIGITAL RADIOGRAPHY - EFFECT ON SIGNAL-TO-NOISE RATIO [J].
CHAN, HP ;
LAM, KL ;
WU, YZ .
MEDICAL PHYSICS, 1990, 17 (04) :655-664