The goal of the present work was to test the hypothesis that test frequency,f, does not have a statistically significant effect on the in vitro fatigue life of an acrylic bone cement. Uniaxial constant-amplitude tension-compression fatigue tests were conducted on 12 sets of cements, covering three formulations with three very different viscosities, two different methods of mixing the cement constituents, and two values of f (1 and 10 Hz). The test results (number of fatigue stress cycles, N-f) were analyzed using the linearized form of the three-parameter Weibull equation, allowing the values of the Weibull mean (Nwm) to be determined for each set. Statistical analysis of the In N-f data, together with an examination of the N-WM estimates, showed support for the hypothesis over the range of f used. The principal use and explanation of the present finding are presented. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1111 / 1117
页数:7
相关论文
共 33 条
[1]   FATIGUE CRACK-PROPAGATION IN POLYMETHYLMETHACRYLATE - EFFECT OF LOADING FREQUENCY [J].
ARAD, S ;
RADON, JC ;
CULVER, LE .
JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1972, 14 (05) :328-&
[2]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[3]   MODELING OF THE FREQUENCY EFFECT ON FATIGUE CRACK-PROPAGATION IN PMMA [J].
CHOU, YF ;
SUN, CT .
ENGINEERING FRACTURE MECHANICS, 1983, 17 (01) :17-26
[4]  
COOKE FW, 1999, T 25 ANN M SOC BIOM, P97
[5]  
Dowling N.E., 1999, MECH BEHAV MAT
[6]  
GINEBRA MP, 2001, T 16 EUR C BIOM LOND
[7]  
HASTINGS NAJ, 1975, STAT DISTRIBUTIONS
[8]   THE EFFECT OF THE TYPE OF CEMENT ON EARLY REVISION OF CHARNLEY TOTAL HIP PROSTHESES - A REVIEW OF 8,579 PRIMARY ARTHROPLASTIES FROM THE NORWEGIAN ARTHROPLASTY REGISTER [J].
HAVELIN, LI ;
ESPEHAUG, B ;
VOLLSET, SE ;
ENGESAETER, LB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (10) :1543-1550
[9]  
HEALY RM, 1998, T 44 ANN M ORTH RES, P422
[10]  
Hertzberg RW, 1980, FATIGUE ENG PLASTICS