Evaluation of three different bottles in BACTEC 9240 automated blood culture system and direct identification of Candida species to shorten the turnaround time of blood culture

被引:10
|
作者
Gokbolat, Egemen [1 ,3 ]
Oz, Yasemin [1 ]
Metintas, Selma [2 ]
机构
[1] Eskisehir Osmangazi Univ, Fac Med, Dept Microbiol, Eskisehir, Turkey
[2] Eskisehir Osmangazi Univ, Fac Med, Dept Publ Hlth, Eskisehir, Turkey
[3] Burdur State Hosp, Dept Microbiol, Burdur, Turkey
关键词
blood culture; Candida; direct identification; time to positivity; YEAST TRAFFIC LIGHT; RAPID IDENTIFICATION; CHROMAGAR CANDIDA; STREAM INFECTIONS; PNA-FISH; CHROMOGENIC MEDIUM; CLINICAL IMPACT; POSITIVITY; MORTALITY; ALBICANS;
D O I
10.1099/jmm.0.000434
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Purpose. Candida spp. are the most common causes of fungemia. Rapid and accurate diagnostic methods are very important for appropriate management of candidemia. At present, blood culture is the essential diagnostic test despite having a long detection time and low sensitivity rate. We aimed to investigate the ways to shorten the turnaround time from blood culture collection to final identification in candidemia. Methodology. Sixty clinical bloodstream isolates of Candida were included, and Plus Aerobic/F, Peds Plus/F and Mycosis IC/Fbottles were used with a BACTEC 9240 blood culture instrument. Germ tube production, carbohydrate assimilation (API 20C AUX) and peptide nucleic acid fluorescent in situ hybridization yeast traffic light tests were performed directly from positive-signalled bottles. Results. Time to positivity of blood cultures was affected by species of Candida, fungal load and bottle type. Candida tropicalis had the shortest and Candida glabrata had the longest time to positivity. Mycosis IC/F culture bottle had a significant superiority in the isolation of yeasts, especially for C. glabrata and if there was a low fungal load in the bottle. Direct germ tube test had 90% sensitivity and 97.6% specificity for Candida albicans in two hours after signalling. The compliance between direct and classical assimilation tests was 98.3 %. Sensitivity and specificity of peptide nucleic acid fluorescent in situ hybridization were 100 %. Conclusion. We think that it is possible to shorten the turnaround time for the identification of Candida in blood culture even with currently available methods.
引用
收藏
页码:470 / 476
页数:7
相关论文
共 50 条
  • [31] Evaluation of three protocols for direct susceptibility testing for Gram-negative rods from flagged positive blood culture bottles
    Khan, Salman
    Das, Arghya
    Mishra, Anwita
    Vidyarthi, Ashima Jain
    Nandal, Mukesh
    Yadav, Himanshu
    Roy, Shayak
    Singh, Mahipal
    MICROBIOLOGY SPECTRUM, 2024, 12 (04):
  • [32] Direct identification of microorganisms in positive blood culture bottles by mass spectrometry (MALDI-TOF MS)
    Azula, Natalia
    Relloso, Silvia
    Barrios, Ruben
    Nicola, Federico
    Smayevsky, Jorgelina
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2022, 56 (01): : 17 - 31
  • [33] Clinical evaluation of FAPlus/FNPlus bottles compared with the combination of SA/SN and FA/FN bottles in the BacT/Alert blood culture system
    Hattori, Takuya
    Nishiyama, Hideki
    Ikegami, Shinobu
    Minoshima, Makoto
    Kato, Hideki
    Yuasa, Norihiro
    JOURNAL OF MEDICAL INVESTIGATION, 2020, 67 (1-2) : 90 - 94
  • [34] Rapid Differentiation of Candida albicans from Non-albicans Species by Germ Tube Test Directly From Blood Culture Bottles
    Yilmaz, Kerem
    Demiray, Tayfur
    Koroglu, Mehmet
    Hatipoglu, Huseyin
    Kilic, Umit
    Karabay, Oguz
    Altindis, Mustafa
    MEDITERRANEAN JOURNAL OF INFECTION MICROBES AND ANTIMICROBIALS, 2019, 8
  • [35] Rapid Identification of Candida Species from Positive Blood Cultures by Use of the FilmArray Blood Culture Identification Panel
    Simor, Andrew E.
    Porter, Vanessa
    Mubareka, Samira
    Chouinard, Marc
    Katz, Kevin
    Vermeiren, Christie
    Fattouh, Ramzi
    Matukas, Larissa M.
    Tadros, Manal
    Mazzulli, Tony
    Poutanen, Susan
    JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (12)
  • [36] Comparison of the two blood culture systems, Bactec 9240 and BacT/Alert 3D, in the detection of Candida spp. and bacteria with polymicrobial sepsis
    L. Klingspor
    S. A. Muhammed
    V. Özenci
    European Journal of Clinical Microbiology & Infectious Diseases, 2012, 31 : 2983 - 2987
  • [37] Evaluation of Wider System for Direct Identification and Antimicrobial Susceptibility Testing of Gram-Negative Bacilli from Positive Blood Culture Bottles
    D. Fontanals
    F. Salceda
    J. Hernández
    I. Sanfeliu
    M. Torra
    European Journal of Clinical Microbiology and Infectious Diseases , 2002, 21 : 693 - 695
  • [38] Multi-probe Real-Time PCR Identification of Four Common Candida Species in Blood Culture Broth
    Foongladda, Suporn
    Mongkol, Nanthanida
    Petlum, Pornphan
    Chayakulkeeree, Methee
    MYCOPATHOLOGIA, 2014, 177 (5-6) : 251 - 261
  • [39] Rapid identification,fluconazole and micafungin susceptibility testing of Candida species from blood culture by a short incubation method
    de Souza, Andrea Celestino
    Pereira, Dariane Castro
    Barth, Patricia Orlandi
    Roesch, Eliane Wurdig
    Lutz, Larissa
    Aquino, Valerio Rodrigues
    Goldani, Luciano Zubaran
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2024, 109 (02)
  • [40] Quantamatrix Multiplexed Assay Platform system for direct detection of bacteria and antibiotic resistance determinants in positive blood culture bottles
    Wang, H. Y.
    Uh, Y.
    Kim, S.
    Lee, H.
    CLINICAL MICROBIOLOGY AND INFECTION, 2017, 23 (05) : 333.e1 - 333.e7