Evaluation of three different bottles in BACTEC 9240 automated blood culture system and direct identification of Candida species to shorten the turnaround time of blood culture

被引:10
|
作者
Gokbolat, Egemen [1 ,3 ]
Oz, Yasemin [1 ]
Metintas, Selma [2 ]
机构
[1] Eskisehir Osmangazi Univ, Fac Med, Dept Microbiol, Eskisehir, Turkey
[2] Eskisehir Osmangazi Univ, Fac Med, Dept Publ Hlth, Eskisehir, Turkey
[3] Burdur State Hosp, Dept Microbiol, Burdur, Turkey
关键词
blood culture; Candida; direct identification; time to positivity; YEAST TRAFFIC LIGHT; RAPID IDENTIFICATION; CHROMAGAR CANDIDA; STREAM INFECTIONS; PNA-FISH; CHROMOGENIC MEDIUM; CLINICAL IMPACT; POSITIVITY; MORTALITY; ALBICANS;
D O I
10.1099/jmm.0.000434
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Purpose. Candida spp. are the most common causes of fungemia. Rapid and accurate diagnostic methods are very important for appropriate management of candidemia. At present, blood culture is the essential diagnostic test despite having a long detection time and low sensitivity rate. We aimed to investigate the ways to shorten the turnaround time from blood culture collection to final identification in candidemia. Methodology. Sixty clinical bloodstream isolates of Candida were included, and Plus Aerobic/F, Peds Plus/F and Mycosis IC/Fbottles were used with a BACTEC 9240 blood culture instrument. Germ tube production, carbohydrate assimilation (API 20C AUX) and peptide nucleic acid fluorescent in situ hybridization yeast traffic light tests were performed directly from positive-signalled bottles. Results. Time to positivity of blood cultures was affected by species of Candida, fungal load and bottle type. Candida tropicalis had the shortest and Candida glabrata had the longest time to positivity. Mycosis IC/F culture bottle had a significant superiority in the isolation of yeasts, especially for C. glabrata and if there was a low fungal load in the bottle. Direct germ tube test had 90% sensitivity and 97.6% specificity for Candida albicans in two hours after signalling. The compliance between direct and classical assimilation tests was 98.3 %. Sensitivity and specificity of peptide nucleic acid fluorescent in situ hybridization were 100 %. Conclusion. We think that it is possible to shorten the turnaround time for the identification of Candida in blood culture even with currently available methods.
引用
收藏
页码:470 / 476
页数:7
相关论文
共 50 条
  • [1] Growth Time of Candida Species in Blood Culture Bottles and Approaches to Improve This Time
    Sahin, Elif Ayca
    Kalkanci, Ayse
    FLORA INFEKSIYON HASTALIKLARI VE KLINIK MIKROBIYOLOJI DERGISI, 2022, 27 (02): : 241 - 248
  • [2] Multicenter Evaluation of Candida QuickFISH BC for Identification of Candida Species Directly from Blood Culture Bottles
    Abdelhamed, Ayman M.
    Zhang, Sean X.
    Watkins, Tonya
    Morgan, Margie A.
    Wu, Fann
    Buckner, Rebecca J.
    Fuller, DeAnna D.
    Davis, Thomas E.
    Salimnia, Hossein
    Fairfax, Marilynn R.
    Lephart, Paul R.
    Poulter, Melinda D.
    Regi, Sarah B.
    Jacobs, Michael R.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (05) : 1672 - 1676
  • [3] Evaluation of BACTEC 9240 blood culture system by using the aerobic 9240 medium for fungemia detection
    FrickerHidalgo, H
    ChirpazCerbat, A
    Lebeau, B
    AmbroiseThomas, P
    Grillot, R
    JOURNAL DE MYCOLOGIE MEDICALE, 1997, 7 (03): : 128 - 133
  • [4] Clinical Relevance of Time-to-positivity in BACTEC9240 Blood Culture System
    Park, Sang Hyuk
    Shim, Hyoeun
    Yoon, Nam Seop
    Kim, Mi-Na
    KOREAN JOURNAL OF LABORATORY MEDICINE, 2010, 30 (03): : 276 - 283
  • [5] Bactec 9240 blood culture system:: to preincubate at 35 °C or not?
    Lemming, L
    Holt, HM
    Petersen, IS
    Ostergaard, C
    Bruun, B
    CLINICAL MICROBIOLOGY AND INFECTION, 2004, 10 (12) : 1089 - 1091
  • [6] Seminested PCR for detection and identification of Candida species directly from blood culture bottles
    Cerikcioglu, Nilguen
    Aksu, Burak
    Dal, Tuba Demirel
    Deniz, Umut
    Bilgen, Huelya Selva
    Ozek, Eren
    Soyletir, Guner
    NEW MICROBIOLOGICA, 2010, 33 (01) : 57 - 62
  • [7] Recovery and time to growth of isolates in blood culture bottles: Comparison of BD Bactec Plus Aerobic/F and BD Bactec Plus Anaerobic/F bottles
    Passerini, Rita
    Cassatella, Maria Cristina
    Salvatici, Michela
    Bottari, Fabio
    Mauro, Cristian
    Radice, Davide
    Sandri, Maria Teresa
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2014, 46 (04) : 288 - 293
  • [8] Evaluation of MicroScan and Phoenix System for Rapid Identification and Susceptibility Testing Using Direct Inoculation from Positive BACTEC Blood Culture Bottles
    Chung, Jae-Woo
    Jeon, Hong-Seon
    Sung, Heungsup
    Kim, Mi-Na
    KOREAN JOURNAL OF LABORATORY MEDICINE, 2009, 29 (01): : 25 - 34
  • [9] Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system
    Ozen, N. S.
    Ogunc, D.
    Mutlu, D.
    Ongut, G.
    Baysan, B. O.
    Gunseren, F.
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2011, 29 (01) : 42 - 46
  • [10] Direct identification of bacteria from positive BD-Bactec blood culture bottles on the Vitek MS
    McAuliffe, Gary N.
    Bilkey, Mary
    Roberts, Sally A.
    PATHOLOGY, 2015, 47 (01) : 88 - 91