Biosensor for luteolin based on silver or gold nanoparticles in ionic liquid and laccase immobilized in chitosan modified with cyanuric chloride

被引:80
作者
Franzoi, Ana Cristina [1 ]
Vieira, Iolanda Cruz [1 ]
Dupont, Jairton [2 ]
Scheeren, Carla Weber [2 ]
de Oliveira, Luciane Franca [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, Lab Biossensores, BR-88040970 Florianopolis, SC, Brazil
[2] Univ Fed Rio Grande do Sul, Dept Quim Organ, Lab Catalise Mol, BR-91501970 Porto Alegre, RS, Brazil
关键词
CAPILLARY-ELECTROPHORESIS; CHLOROGENIC ACID; RAT PLASMA; PEROXIDASE; FLAVONOIDS; APIGENIN; MICROSPHERES; CONSTRUCTION; CATALYSIS; ELECTRODE;
D O I
10.1039/b911952c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel and effective biosensors based on Ag or Au nanoparticles dispersed in ionic liquid (IL) 1-butyl-3-methylimidazolium hexafluorophosphate (BMI.PF6) and laccase (Lac) from Aspergillus oryzae immobilized in chitosan (Chi) chemically cross-linked with cyanuric chloride (CC) were constructed. This enzyme catalyzes the oxidation of luteolin to the corresponding o-quinone, which is electrochemically reduced back to luteolin at 0.35 V vs. Ag/AgCl. Square-wave voltammetry was used for the electrochemical determination of luteolin at the Lac-nanoparticles-BMI.PF6 biosensors. The best performance was obtained with 50: 20: 15: 15% (w/w/w/w) as the graphite powder: Chi-CC:Nujol:Ag-BMI.PF6 or Au-BMI.PF6 composition (Lac 0.29 units mL(-1)) in 0.1 M acetate buffer solution (pH 4.0) with frequency, pulse amplitude and scan increment at 50 Hz, 100 mV, and 5.0 mV, respectively. Under optimized conditions, the cathodic currents increased linearly for the luteolin concentration range of 0.099-5.825 mM with detection limits of 0.054 +/- 0.004 mu M (Ag-BMI.PF6) and 0.028 +/- 0.002 mu M (Au-BMI.PF6). These biosensors demonstrated high sensitivity, good repeatability and reproducibility, and long-term stability (13% decrease in response over 70 days). The recovery study for luteolin in chamomile tea samples gave values of 91.8-104.8%. The influence of Lac immobilized in Chi-CC and nanoparticles-BMI.PF6 contributes to the excellent performance of the biosensors.
引用
收藏
页码:2320 / 2328
页数:9
相关论文
共 48 条
[11]   1-Methylimidazole stabilization of gold nanoparticles in imidazolium ionic liquids [J].
Dash, Priyabrat ;
Scott, Robert W. J. .
CHEMICAL COMMUNICATIONS, 2009, (07) :812-814
[12]   Immobilization procedures for the development of a biosensor for determination of hydroquinone using chitosan and gilo (Solanum gilo) [J].
de Oliveira, IRWZ ;
Vieira, IC .
ENZYME AND MICROBIAL TECHNOLOGY, 2006, 38 (3-4) :449-456
[13]   Ionic liquid (molten salt) phase organometallic catalysis [J].
Dupont, J ;
de Souza, RF ;
Suarez, PAZ .
CHEMICAL REVIEWS, 2002, 102 (10) :3667-3691
[14]   Acidichromism and ionochromism of luteolin and apigenin, the main components of the naturally occurring yellow weld: A spectrophotometric and fluorimetric study [J].
Favaro, G. ;
Clementi, C. ;
Romani, A. ;
Vickackaite, V. .
JOURNAL OF FLUORESCENCE, 2007, 17 (06) :707-714
[15]   Biosensor for chlorogenic acid based on an ionic liquid containing iridium nanoparticles and polyphenol oxidase [J].
Fernandes, Suellen C. ;
Moccelini, Sally K. ;
Scheeren, Carla W. ;
Migowski, Pedro ;
Dupont, Jairton ;
Heller, Melina ;
Micke, Gustavo A. ;
Vieira, Iolanda C. .
TALANTA, 2009, 79 (02) :222-228
[16]   Biosensor based on laccase immobilized on microspheres of chitosan crosslinked with tripolyphosphate [J].
Fernandes, Suellen Cadorin ;
de Oliveira, Ines Rosane W. Z. ;
Fatibello-Filho, Oralndo ;
Spinelli, Almir ;
Vieira, Iolanda Cruz .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (01) :202-207
[17]   Development of biosensors containing laccase and imidazolium bis(trifluoromethylsulfonyl)imide ionic liquid for the determination of rutin [J].
Franzoi, Ana Cristina ;
Migowski, Pedro ;
Dupont, Jairton ;
Vieira, Iolanda Cruz .
ANALYTICA CHIMICA ACTA, 2009, 639 (1-2) :90-95
[18]   Biosensor based on laccase and an ionic liquid for determination of rosmarinic acid in plant extracts [J].
Franzoi, Ana Cristina ;
Dupont, Jairton ;
Spinelli, Almir ;
Vieira, Iolanda Cruz .
TALANTA, 2009, 77 (04) :1322-1327
[19]   Modification of carbon electrode in ionic liquid through the reduction of phenyl diazonium salt. Electrochemical evidence in ionic liquid [J].
Ghilane, Jalal ;
Martin, Pascal ;
Fontaine, Olivier ;
Lacroix, Jean-Christophe ;
Randriamahazaka, Hyacinthe .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (07) :1060-1063
[20]   Development of a stable cholesterol biosensor based on multi-walled carbon nanotubes-gold nanoparticles composite covered with a layer of chitosan-room-temperature ionic liquid network [J].
Gopalan, Anantha Iyengar ;
Lee, Kwang-Pill ;
Ragupathy, Dhanusuraman .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) :2211-2217