Comparison of plateletpheresis on the Fresenius AS.TEC 204 and haemonetics MCS 3p

被引:11
作者
Ranganathan, Sudha [1 ]
机构
[1] Global Hosp, Hyderabad, Andhra Pradesh, India
关键词
plateletpheresis; AS.TEC204; haemonetics MCS3p;
D O I
10.1002/jca.20108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This is an attempt at comparing two cell separators for plateletpheresis, namely the Fresenius AS.TEC 204 and Haemonetics MCS 3p, at a tertiary care center in India. Donors who weighed between 55-75 kg, who had a hematocrit of 41-43%, and platelet counts of 250 X 10(3) 400 X 10(3)/mu l were selected for the study. The comparability of the donors who donated on the two cell separators were analysed by t-test independent samples and no significant differences were found (P > 0.05). The features compared were time taken for the procedure, volume processed on the separators, adverse reactions of the donors, quality control of the product, separation efficiency of the separators, platelet loss in the donors after the procedure, and the predictor versus the actual yield of platelets given by the cell separator. The volume processed to get a target yield of > 3 X 10(11) was equal to 2.8-3.21 and equal in both the cell separators. Symptoms of citrate toxicity were seen in 4 and 2.5% of donors who donated on the MCS 3p and the AS.TEC 204, respectively, and 3 and 1% of donors, respectively, had vasovagal reactions. All the platelet products collected had a platelet count of > 3 X 10(11); 90% of the platelet products collected on the AS.TEC 204 attained the predicted yield that was set on the cell separator where as 75% of the platelet products collected on the MCS 3p attained the target yield. Quality control of the platelets collected on both the cell separators complied with the standards except that 3% of the platelets collected on the MCS 3p had a visible red cell contamination. The separation efficiency of the MCS 3p was higher, 50-52% as compared to the 40-45% on the AS.TEC 204. A provision of double venous access, less adverse reactions, negligible RBC contamination with a better predictor yield of platelets makes the AS.TEC 204 a safer and more reliable alternative than the widely used Haemonetics MCS 3p.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 5 条
  • [1] Comparative study of plateletpheresis using Baxter CS 3000 plus and Haemonetics MCS 3p
    Patel, AP
    Kaur, A
    Patel, V
    Patel, N
    Shah, D
    Kanvinde, S
    Prajapati, S
    Patel, H
    Rathod, D
    Adesara, R
    Rani, S
    JOURNAL OF CLINICAL APHERESIS, 2004, 19 (03) : 137 - 141
  • [2] Collection of platelets and peripheral progenitor cells with the Fresenius AS.TEC 204 blood cell separator
    Moog, R
    Valbonesi, M
    Carlier, P
    Muller, N
    Eisenbeisz, F
    Mitschulat, H
    JOURNAL OF CLINICAL APHERESIS, 1997, 12 (03) : 126 - 129
  • [3] Comparison of Plateletpheresis on the Fenwal Amicus and Fresenius Com.Tec Cell Separators
    Altuntas, Fevzi
    Sari, Ismail
    Kocyigit, Ismail
    Kaynar, Leylagul
    Hacioglu, Sibel
    Ozturk, Ahmet
    Oztekin, Mehmet
    Solmaz, Musa
    Eser, Bulent
    Cetin, Mustafa
    Unal, Ali
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2008, 35 (05) : 368 - 373
  • [4] COMPARISON OF DIFFERENT PROTOCOLS IN PLATELETPHERESIS WITH THE HEMONETICS MCS 3P BLOOD-CELL SEPARATOR WITH RESPECT TO PARAMETERS OF PRODUCT QUALITY
    MOOG, R
    MULLER, N
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1995, 22 (04): : 244 - 248
  • [5] Comparison of plateletpheresis on the Fenwal Amicus, Fresenius COM.TEC, and Trima Accel Cell separators
    Keklik, Muzaffer
    Eser, Bulent
    Kaynar, Leylagul
    Sivgin, Serdar
    Keklik, Ertugrul
    Solmaz, Musa
    Ozturk, Ahmet
    Buyukoglan, Ruksan
    Yay, Mehmet
    Cetin, Mustafa
    Unal, Ali
    JOURNAL OF CLINICAL APHERESIS, 2015, 30 (03) : 171 - 175