Optimal Design of an Hourglass in-Fiber Air Fabry-Perot Microcavity-Towards Spectral Characteristics and Strain Sensing Technology

被引:3
作者
Wang, Qi [1 ,2 ]
Yan, Dongchao [1 ]
Cui, Binbin [1 ]
Guo, Zixuan [1 ]
机构
[1] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Peoples R China
[2] Northeastern Univ, State Key Lab Synthet Automat Proc Ind, Shenyang 110819, Peoples R China
来源
SENSORS | 2017年 / 17卷 / 06期
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
fiber Fabry-Perot interferometer; in-fiber air microcavity; spectral characteristics; strain; high fringe contrast; high resolution; MACH-ZEHNDER INTERFEROMETER; SENSOR;
D O I
10.3390/s17061282
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An hourglass in-fiber air microcavity Fabry-Perot interferometer is proposed in this paper, and its second reflecting surface of in-fiber microcavity is designed to be a concave reflector with the best curvature radius in order to improve the spectral characteristics. Experimental results proved that the extinction ratio of Fabry-Perot interferometer with cavity length of 60 mu m and concave reflector radius of 60 mu mis higher than for a rectangular Fabry-Perot interferometer with cavity length of 60 mu m (14 dB: 11 dB). Theory and numerical simulation results show that the strain sensitivity of sensor can be improved by reducing the microcavity wall thickness and microcavity diameter, and when the in-fiber microcavity length is 40 mu m, the microcavity wall thickness is 10 mu m, the microcavity diameter is 20 mu m, and the curvature radius of reflective surface II is 50 mu m, the interference fringe contrast of is greater than 0.97, an Axial-pull sensitivity of 20.46 nm/N and resolution of 1 mN can be achieved in the range of 0-1 N axial tension. The results show that the performance of hourglass in-fiber microcavity interferometer is far superior to that of the traditional Fabry-Perot interferometer.
引用
收藏
页数:12
相关论文
共 37 条
  • [31] Fabry-Perot based strain insensitive photonic crystal fiber modal interferometer for inline sensing of refractive index and temperature
    Dash, Jitendra Narayan
    Jha, Rajan
    APPLIED OPTICS, 2015, 54 (35) : 10479 - 10486
  • [32] Sapphire derived fiber based Fabry-Perot interferometer with an etched micro air cavity for strain measurement at high temperatures
    Zhang, Penghao
    Zhang, Li
    Wang, Zhongyu
    Zhang, Xinying
    Shang, Zhendong
    OPTICS EXPRESS, 2019, 27 (19) : 27112 - 27123
  • [33] Tapered Hollow-Core Fiber Air-Microbubble Fabry-Perot Interferometer for High Sensitivity Strain Measurement
    Zhao, Yong
    Chen, Mao-qing
    Peng, Yun
    ADVANCED MATERIALS INTERFACES, 2018, 5 (21):
  • [34] Fiber-Bragg-Grating Based Single Axial Mode Fabry-Perot Interferometer and Its Strain and Acceleration Sensing Applications
    Yoshino, Toshihiko
    Sano, Yasukazu
    Ota, Daisuke
    Fujita, Keiichi
    Ikui, Takahiro
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2016, 34 (09) : 2240 - 2250
  • [35] Temperature-insensitive fiber optic Fabry-Perot interferometer based on special air cavity for transverse load and strain measurements
    Wu, Yongfeng
    Zhang, Yundong
    Wu, Jing
    Yuan, Ping
    OPTICS EXPRESS, 2017, 25 (08): : 9443 - 9448
  • [36] Temperature-insensitive optical fiber strain sensor fabricated by two parallel connection Fabry-Perot interferometers with air-bubbles
    Zhang, Han
    Jiang, Chao
    Hu, Jin
    Song, Jiao
    Zhu, Xiping
    Wang, Pei
    Li, Hong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (04)
  • [37] High-Sensitivity Transverse-Load and Axial-Strain Sensor Based on Air-Bubble Fabry-Perot Cavity and Fiber Sagnac Loop Cascaded
    Zhang, Han
    Jiang, Chao
    Zhu, Xiping
    Hu, Jin
    Wang, Pei
    Li, Hong
    Sun, Simei
    Cao, Tingshui
    IEEE SENSORS JOURNAL, 2023, 23 (06) : 5795 - 5802