3D kernel-density stochastic model for more personalized glycaemic control: development and in-silico validation

被引:21
作者
Uyttendaele, Vincent [1 ,2 ]
Knopp, Jennifer L. [1 ]
Davidson, Shaun [1 ]
Desaive, Thomas [2 ]
Benyo, Balazs [3 ]
Shaw, Geoffrey M. [4 ,5 ]
Chase, J. Geoffrey [1 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Private Bag 4800, Christchurch, New Zealand
[2] Univ Liege, GIGA In Silico Med, Allee 6 Aout 19,Bat B5a, B-4000 Liege, Belgium
[3] Budapest Univ Technol & Econ, Dept Control Engn & Informat Technol, Budapest, Hungary
[4] Christchurch Hosp, Dept Intens Care Christchurch, Christchurch, New Zealand
[5] Univ Otago, Sch Med, Christchurch, New Zealand
关键词
Glycaemic control; Hyperglycaemia; Blood glucose; Insulin; Insulin sensitivity; Kernel density; CONVENTIONAL GLUCOSE CONTROL; INTENSIVE INSULIN THERAPY; CRITICALLY-ILL PATIENTS; MORTALITY; SENSITIVITY; VARIABILITY; PROTOCOL; CARE; ICU; HYPERGLYCEMIA;
D O I
10.1186/s12938-019-0720-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundThe challenges of glycaemic control in critically ill patients have been debated for 20 years. While glycaemic control shows benefits inter- and intra-patient metabolic variability results in increased hypoglycaemia and glycaemic variability, both increasing morbidity and mortality. Hence, current recommendations for glycaemic control target higher glycaemic ranges, guided by the fear of harm. Lately, studies have proven the ability to provide safe, effective control for lower, normoglycaemic, ranges, using model-based computerised methods. Such methods usually identify patient-specific physiological parameters to personalize titration of insulin and/or nutrition. The Stochastic-Targeted (STAR) glycaemic control framework uses patient-specific insulin sensitivity and a stochastic model of its future variability to directly account for both inter- and intra-patient variability in a risk-based insulin-dosing approach.ResultsIn this study, a more personalized and specific 3D version of the stochastic model used in STAR is compared to the current 2D stochastic model, both built using kernel-density estimation methods. Fivefold cross validation on 681 retrospective patient glycaemic control episodes, totalling over 65,000 h of control, is used to determine whether the 3D model better captures metabolic variability, and the potential gain in glycaemic outcome is assessed using validated virtual trials. Results show that the 3D stochastic model has similar forward predictive power, but provides significantly tighter, more patient-specific, prediction ranges, showing the 2D model over-conservative>70% of the time. Virtual trial results show that overall glycaemic safety and performance are similar, but the 3D stochastic model reduced median blood glucose levels (6.3 [5.7, 7.0] vs. 6.2 [5.6, 6.9]) with a higher 61% vs. 56% of blood glucose within the 4.4-6.5 mmol/L range.ConclusionsThis improved performance is achieved with higher insulin rates and higher carbohydrate intake, but no loss in safety from hypoglycaemia. Thus, the 3D stochastic model developed better characterises patient-specific future insulin sensitivity dynamics, resulting in improved simulated glycaemic outcomes and a greater level of personalization in control. The results justify inclusion into ongoing clinical use of STAR.
引用
收藏
页数:18
相关论文
共 3 条
  • [1] 3D kernel-density stochastic model for more personalized glycaemic control: development and in-silico validation
    Vincent Uyttendaele
    Jennifer L. Knopp
    Shaun Davidson
    Thomas Desaive
    Balazs Benyo
    Geoffrey M. Shaw
    J. Geoffrey Chase
    BioMedical Engineering OnLine, 18
  • [2] A 3D insulin sensitivity prediction model enables more patient-specific prediction and model-based glycaemic control
    Uyttendaele, Vincent
    Knopp, Jennifer L.
    Stewart, Kent W.
    Desaive, Thomas
    Benyo, Balazs
    Szabo-Nemedi, Noemi
    Illyes, Attila
    Shaw, Geoffrey M.
    Chase, J. Geoffrey
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 46 : 192 - 200
  • [3] Stochastic Model Predictive (STOMP) glycaemic control for the intensive care unit: Development and virtual trial validation
    Stewart, Kent W.
    Pretty, Christopher G.
    Tomlinson, Hamish
    Fisk, Liam
    Shaw, Geoffrey M.
    Chase, J. Geoffrey
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 16 : 61 - 67