Tomographic reconstruction using tilted Laue analyser-based X-ray phase-contrast imaging

被引:1
作者
Chalmers, M. C. [1 ]
Kitchen, M. J. [2 ]
Uesugi, K. [3 ]
Falzon, G. [4 ,5 ]
Quin, P. [5 ,6 ]
Pavlov, K. M. [1 ,2 ,5 ]
机构
[1] Univ Canterbury, 20 Kirkwood Ave, Christchurch 8041, New Zealand
[2] Monash Univ, Wellington Rd, Clayton, Vic 3800, Australia
[3] Japan Synchrotron Radiat Res Inst, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
[4] Flinders Univ S Australia, Coll Sci & Engn, Adelaide, SA 5001, Australia
[5] Univ New England, Armidale, NSW 2351, Australia
[6] Univ Tasmania, Churchill Ave, Hobart, Tas 7005, Australia
关键词
phase-contrast imaging; phase-contrast tomography; analyser-based imaging; phase retrieval; DIFFRACTION; ABSORPTION; REFRACTION; SCATTERING; APPROXIMATION; INFORMATION; PROPAGATION; REFLECTION; EXTRACTION; RETRIEVAL;
D O I
10.1107/S1600577520013995
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Analyser-based phase-contrast imaging (ABPCI) is a highly sensitive phase-contrast imaging method that produces high-contrast images of weakly absorbing materials. However, it is only sensitive to phase gradient components lying in the diffraction plane of the analyser crystal [i.e. in one dimension (1-D)]. In order to accurately account for and measure phase effects produced by the wavefield-sample interaction, ABPCI and other 1-D phase-sensitive methods must achieve 2-D phase gradient sensitivity. An inclined geometry method was applied to a Laue geometry setup for X-ray ABPCI through rotation of the detector and object about the optical axis. This allowed this traditionally 1-D phase-sensitive phase-contrast method to possess 2-D phase gradient sensitivity. Tomographic datasets were acquired over 360 degrees of a multi-material phantom with the detector and sample tilted by 8 degrees. The real and imaginary parts of the refractive index were reconstructed for the phantom.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 50 条
[41]   Single-image phase retrieval using an edge illumination X-ray phase-contrast imaging setup [J].
Diemoz, Paul C. ;
Vittoria, Fabio A. ;
Hagen, Charlotte K. ;
Endrizzi, Marco ;
Coan, Paola ;
Brun, Emmanuel ;
Wagner, Ulrich H. ;
Rau, Christoph ;
Robinson, Ian K. ;
Bravin, Alberto ;
Olivo, Alessandro .
JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 :1072-1077
[42]   Wave optics simulation of grating-based X-ray phase-contrast imaging using 4D Mouse Whole Body (MOBY) phantom [J].
Sung, Yongjin ;
Nelson, Brandon ;
Shanblatt, Elisabeth R. ;
Gupta, Rajiv ;
McCollough, Cynthia H. ;
Graves, William S. .
MEDICAL PHYSICS, 2020, 47 (11) :5761-5771
[43]   Analyzer-based phase-contrast imaging system using a micro focus x-ray source [J].
Zhou, Wei ;
Majidi, Keivan ;
Brankov, Jovan G. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (08)
[44]   A laboratory based edge-illumination x-ray phase-contrast imaging setup with two-directional sensitivity [J].
Kallon, Gibril K. ;
Wesolowski, Michal ;
Vittoria, Fabio A. ;
Endrizzi, Marco ;
Basta, Dario ;
Millard, Thomas P. ;
Diemoz, Paul C. ;
Olivo, Alessandro .
APPLIED PHYSICS LETTERS, 2015, 107 (20)
[45]   X-ray dark-field and phase-contrast imaging using a grating interferometer [J].
Pfeiffer, F. ;
Bech, M. ;
Bunk, O. ;
Donath, T. ;
Henrich, B. ;
Kraft, P. ;
David, C. .
JOURNAL OF APPLIED PHYSICS, 2009, 105 (10)
[46]   X-ray phase-contrast ghost imaging using a single-pixel camera [J].
Olbinado, Margie P. ;
Paganin, David M. ;
Cheng, Yin ;
Rack, Alexander .
OPTICA, 2021, 8 (12) :1538-1544
[47]   Contrast enhancement of propagation based X-ray phase contrast imaging [J].
Pan, Adam ;
Xu, Ling ;
Petruccelli, Jon C. ;
Gupta, Rajiv ;
Barbastathis, George .
ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
[48]   Sensitivity of laboratory based implementations of edge illumination X-ray phase-contrast imaging [J].
Diemoz, P. C. ;
Hagen, C. K. ;
Endrizzi, M. ;
Olivo, A. .
APPLIED PHYSICS LETTERS, 2013, 103 (24)
[49]   Spectral x-ray imaging: Conditions under which propagation-based phase-contrast is beneficial [J].
Schaff, Florian ;
Morgan, Kaye S. ;
Paganin, David M. ;
Kitchen, Marcus J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (20)
[50]   Redefining the lower statistical limit in x-ray phase-contrast imaging [J].
Marschner, M. ;
Birnbacher, L. ;
Willner, M. ;
Chabior, M. ;
Fehringer, A. ;
Herzen, J. ;
Noel, P. B. ;
Pfeiffer, F. .
MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412