Identification and Localization of Array Faults With Optimized Placement of Voltage Sensors in a PV System

被引:33
作者
Kumar, B. Pradeep [1 ]
Pillai, Dhanup S. [2 ]
Rajasekar, N. [3 ]
Chakkarapani, Manickam [4 ]
Ilango, G. Saravana [1 ]
机构
[1] Natl Inst Technol, Dept Elect & Elect Engn, Tiruchirappalli 620015, Tamil Nadu, India
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[3] Vellore Inst Technol, Sch Elect Engn, Dept Energy & Power Elect, Solar Energy Res Cell, Vellore 632014, Tamil Nadu, India
[4] Madanapalle Inst Technol & Sci, Dept Elect & Elect Engn, Madanapalle 517325, India
关键词
Circuit faults; Sensor arrays; Sensor systems; Fault detection; Power generation; DH-HEMTs; Differential voltage measurement; LL faults; open-circuit fault; partial shading conditions; photovoltaic array;
D O I
10.1109/TIE.2020.2998750
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The traditional protection devices installed in photovoltaic (PV) arrays generally detect line-line (LL) and line-ground (LG) faults when the fault current magnitude exceeds its threshold value defined by various international standards. However, the magnitude of fault current is greatly reduced, due to low irradiance levels, active maximum power point tracker, location of fault, minimal fault mismatch, and presence of blocking diodes. Consequently, majority of such faults remain obscured even when the irradiance reaches to a higher level and thereby constitute to reliability issues and severe fire risks. Therefore, both timely fault detection and localization become highly obligatory for sustainable power generation and safety. Thus, this article proposes a new, robust, and efficient fault localization method based on the principle of differential voltage measurement between PV modules of adjacent strings. For accomplishing this task, a new optimized voltage sensor arrangement with minimal number of sensors is followed. Moreover, the proposed convention 1) is proficient to detect any LL/LG faults independent of its detection challenges, 2) suits both grounded and floating PV systems, and 3) is compatible for systems with/without blocking diodes. For a realistic validation, testing has been performed on a small-scale grid-connected PV system and the efficacy in detecting various array faults is demonstrated via extensive investigations.
引用
收藏
页码:5921 / 5931
页数:11
相关论文
共 27 条
[1]   Modeling and Health Monitoring of DC Side of Photovoltaic Array [J].
Akram, Mohd Nafis ;
Lotfifard, Saeed .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (04) :1245-1253
[2]  
Alajmi M, 2018, INT CONF ELECTRO INF, P404, DOI 10.1109/EIT.2018.8500264
[3]  
[Anonymous], 2011, SOLAR PRO MAGAZINE
[4]   Adaptive Fault Localization in Photovoltaic Systems [J].
Chen, Leian ;
Wang, Xiaodong .
IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (06) :6752-6763
[5]   Random forest based intelligent fault diagnosis for PV arrays using array voltage and string currents [J].
Chen, Zhicong ;
Han, Fuchang ;
Wu, Lijun ;
Yu, Jinling ;
Cheng, Shuying ;
Lin, Peijie ;
Chen, Huihuang .
ENERGY CONVERSION AND MANAGEMENT, 2018, 178 :250-264
[6]   Monitoring and Diagnostics of PV Plants by a Wireless Self-Powered Sensor for Individual Panels [J].
Guerriero, Pierluigi ;
Di Napoli, Fabio ;
Vallone, Gianlorenzo ;
d'Alessandro, Vincenzo ;
Daliento, Santolo .
IEEE JOURNAL OF PHOTOVOLTAICS, 2016, 6 (01) :286-294
[7]  
Hariharan R, 2016, 2016 INTERNATIONAL CONFERENCE ON ENERGY EFFICIENT TECHNOLOGIES FOR SUSTAINABILITY (ICEETS), P23, DOI 10.1109/ICEETS.2016.7582893
[8]   A Method to Detect Photovoltaic Array Faults and Partial Shading in PV Systems [J].
Hariharan, R. ;
Chakkarapani, M. ;
Ilango, G. Saravana ;
Nagamani, C. .
IEEE JOURNAL OF PHOTOVOLTAICS, 2016, 6 (05) :1278-1285
[9]   Improved kNN-Based Monitoring Schemes for Detecting Faults in PV Systems [J].
Harrou, Fouzi ;
Taghezouit, Bilal ;
Sun, Ying .
IEEE JOURNAL OF PHOTOVOLTAICS, 2019, 9 (03) :811-821
[10]   Online Two-Section PV Array Fault Diagnosis With Optimized Voltage Sensor Locations [J].
Hu, Yihua ;
Zhang, Jiangfeng ;
Cao, Wenping ;
Wu, Jiande ;
Tian, Gui Yun ;
Finney, Stephen J. ;
Kirtley, James L., Jr. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (11) :7237-7246