MONTE CARLO SIMULATION IN ESTABLISHING ANALYTICAL QUALITY REQUIREMENTS FOR CLINICAL LABORATORY TESTS: MEETING CLINICAL NEEDS

被引:31
作者
Boyd, James C. [1 ]
Bruns, David E. [1 ]
机构
[1] Univ Virginia Hlth Syst, Dept Pathol, Charlottesville, VA 22903 USA
来源
METHODS IN ENZYMOLOGY: COMPUTER METHODS, PART B | 2009年 / 467卷
关键词
INTENSIVE INSULIN THERAPY; TIGHT GLUCOSE CONTROL; SPECIFICATIONS; HYPERGLYCEMIA; PERFORMANCE; MANAGEMENT; METERS;
D O I
10.1016/S0076-6879(09)67016-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Introduction. Patient outcomes, such as morbidity and mortality, depend on accurate laboratory test results. Computer simulation of the effects of test performance parameters on outcome measures may represent a valuable approach to defining the quality of assay performance that is needed to provide optimal outcomes. Methods. We carried out computer simulations of patients on intensive insulin treatment to determine the effects of glucose meter imprecision and bias on (1) the frequencies of glucose concentrations >160 mg/dL; (2) the frequencies of hypoglycemia (<60 mg/dL); (3) the mean glucose; and (4) glucose variability. For each patient, starting with a randomly selected initial glucose concentration and individualized responsiveness to insulin, hourly glucose concentrations were simulated to reflect the effects of (1) IV glucose administration, (2) gluconeogenesis, (3) insulin doses as determined using regimens from the University of Washington and Yale University, and (4) errors in glucose measurements by the meter. For each of 45 sets of glucose meter bias and imprecision conditions, 100 patients were simulated, and each patient was followed for 100 h. Results. For both insulin regimens: Mean glucose was inversely related to assay bias; glucose variability increased with negative assay bias and assay imprecision; frequencies of glucose concentrations >160 mg/dL increased with negative assay bias and assay imprecision; and frequencies of hypoglycemia increased with positive assay bias and assay imprecision. Nevertheless, each regimen displayed unique sensitivity to variations in meter imprecision and bias. Conclusions. Errors in glucose measurement exert important regimen-dependent effects on glucose control in intensive IV insulin administration. The results of this proof-of-principle study suggest that simulation of the clinical effects of measurement error is an attractive approach for assessment of assay performance requirements.
引用
收藏
页码:411 / 433
页数:23
相关论文
共 19 条
[1]  
[Anonymous], TIETZ TXB CLIN CHEM
[2]  
Boyd JC, 2001, CLIN CHEM, V47, P209
[3]   Executive summary of the Third Report of the National Cholesterol Education Program (NCEP) expert panel on detection, evaluation, and treatment of high blood cholesterol in adults (Adult Treatment Panel III) [J].
Cleeman, JI ;
Grundy, SM ;
Becker, D ;
Clark, LT ;
Cooper, RS ;
Denke, MA ;
Howard, WJ ;
Hunninghake, DB ;
Illingworth, DR ;
Luepker, RV ;
McBride, P ;
McKenney, JM ;
Pasternak, RC ;
Stone, NJ ;
Van Horn, L ;
Brewer, HB ;
Ernst, ND ;
Gordon, D ;
Levy, D ;
Rifkind, B ;
Rossouw, JE ;
Savage, P ;
Haffner, SM ;
Orloff, DG ;
Proschan, MA ;
Schwartz, JS ;
Sempos, CT ;
Shero, ST ;
Murray, EZ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (19) :2486-2497
[4]   Management of diabetes and is hyperglycemia in hospitals [J].
Clement, S ;
Braithwaite, SS ;
Magee, MF ;
Ahmann, A ;
Smith, EP ;
Schafer, RG ;
Hirsh, IB .
DIABETES CARE, 2004, 27 (02) :553-591
[5]   Intensive versus Conventional Glucose Control in Critically Ill Patients [J].
Finfer, S. ;
Blair, D. ;
Bellomo, R. ;
McArthur, C. ;
Mitchell, I. ;
Myburgh, J. ;
Norton, R. ;
Potter, J. ;
Chittock, D. ;
Dhingra, V. ;
Foster, D. ;
Cook, D. ;
Dodek, P. ;
Hebert, P. ;
Henderson, W. ;
Heyland, D. ;
McDonald, E. ;
Ronco, J. ;
Schweitzer, L. ;
Peto, R. ;
Sandercock, P. ;
Sprung, C. ;
Young, J. D. ;
Su, S. ;
Heritier, S. ;
Li, Q. ;
Bompoint, S. ;
Billot, L. ;
Crampton, L. ;
Darcy, F. ;
Jayne, K. ;
Kumarasinghe, V. ;
Little, L. ;
McEvoy, S. ;
MacMahon, S. ;
Pandey, S. ;
Ryan, S. ;
Shukla, R. ;
Vijayan, B. ;
Atherton, S. ;
Bell, J. ;
Hadfield, L. ;
Hourigan, C. ;
McArthur, C. ;
Newby, L. ;
Simmonds, C. ;
Buhr, H. ;
Eccleston, M. ;
McGuinness, S. ;
Parke, R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (13) :1283-1297
[6]  
Fraser CG, 1999, CLIN CHEM, V45, P321
[7]   Implementation of a safe and effective insulin infusion protocol in a medical intensive care unit [J].
Goldberg, PA ;
Siegel, MD ;
Sherwin, RS ;
Halickman, JI ;
Lee, M ;
Bailey, VA ;
Lee, SL ;
Dziura, JD ;
Inzucchi, SE .
DIABETES CARE, 2004, 27 (02) :461-467
[8]   Intensive insulin therapy and mortality among critically ill patients: a meta-analysis including NICE-SUGAR study data [J].
Griesdale, Donald E. G. ;
de Souza, Russell J. ;
van Dam, Rob M. ;
Heyland, Daren K. ;
Cook, Deborah J. ;
Malhotra, Atul ;
Dhaliwal, Rupinder ;
Henderson, William R. ;
Chittock, Dean R. ;
Finfer, Simon ;
Talmor, Daniel .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2009, 180 (08) :821-827
[9]   Variability among five over-the-counter blood glucose monitors [J].
Kimberly, MM ;
Vesper, HW ;
Caudill, SP ;
Ethridge, SF ;
Archibold, E ;
Porter, KH ;
Myers, GL .
CLINICA CHIMICA ACTA, 2006, 364 (1-2) :292-297
[10]  
Kovatchev Boris P, 2009, J Diabetes Sci Technol, V3, P44