Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair

被引:47
作者
Zannetti, S [1 ]
De Rango, P [1 ]
Parente, B [1 ]
Parlani, G [1 ]
Verzini, F [1 ]
Maselli, A [1 ]
Nardelli, L [1 ]
Cao, P [1 ]
机构
[1] Monteluce Policlin, Unit Operat Chirurg Vasc, I-06122 Perugia, Italy
关键词
aneurysm; aorta; endoleak; duplex scan;
D O I
10.1053/ejvs.1999.1033
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: to validate the role of duplex scan in endoleak detection in postoperative surveillance of endoluminal abdominal aneurysm repair (EAAR). Patients and methods: between April 1997 and March 1999, 103 patients were eligible for duplex and computed tomography (CT) scan after EAAR. Mean follow-up was 8 months (range 1-24 months). The study protocol comprised concurrent examination with colour-duplex and CT scan at 1, 6, and 12 months after EAAR, for a total of 198 concurrent examinations. All duplex scan examinations were performed by two vascular surgeons with the same machine (ATL HDI 3000). Interobserver agreement in endoleak detection (kappa = 1) and in type of endoleak (kappa = 0.7) was evaluated in 50 random duplex examinations. Endoleak detection was examined comparatively in duplex and CT scan, the latter being the gold standard. Sensitivity and specificity tests together with negative- and positive-predictive values (NPV and PPV) were calculated. Results: duplex scan was not feasible in one patient. On CT scan the endoleak rate was 4% at one month, 3% at 6 months, and 4% at one year. Overall, CT scan detected 12 endoleaks. With respect to endoleak detection, duplex scan revealed a great ability in ruling out false-negative results (sensitivity 91.7%, NPV 99.4%), but overestimated the presence of endoleak (specificity 98.4%, PPV 78.6%). Regarding type of endoleak, the ability of duplex scan to identify the source of endoleak was low (sensitivity 66.7%). Conclusions: duplex scan, if validated, appears to be a reliable means for excluding the presence of endoleak after EAAR.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 20 条
[1]  
*AM SOC AN, 1987, BAS STAND PREAN CAR
[2]   Initial experience with endovascular aneurysm repair: Comparison of early results with outcome of conventional open repair [J].
Brewster, DC ;
Geller, SC ;
Kaufman, JA ;
Cambria, RP ;
Gertler, JP ;
LaMuraglia, GM ;
Atamian, S ;
Abbott, WM .
JOURNAL OF VASCULAR SURGERY, 1998, 27 (06) :992-1003
[3]   Ultrasound contrast agents - Basic principles [J].
Calliada, F ;
Campani, R ;
Bottinelli, O ;
Bozzini, A ;
Sommaruga, MG .
EUROPEAN JOURNAL OF RADIOLOGY, 1998, 27 :S157-S160
[4]   Realistic expectations for patients with stent-graft treatment of abdominal aortic aneurysms. Results of a European multicentre registry [J].
Cuypers, P ;
Buth, J ;
Harris, PL ;
Gevers, E ;
Lahey, R .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 17 (06) :507-516
[5]  
Giannoni MF, 1998, J VASC SURG, V27, P981
[6]  
Harris PL, 1997, J ENDOVASC SURG, V4, P72, DOI 10.1583/1074-6218(1997)004<0072:TNFCTO>2.0.CO
[7]  
2
[8]  
Heilberger P, 1997, J ENDOVASC SURG, V4, P262, DOI 10.1583/1074-6218(1997)004<0262:PCFDSI>2.0.CO
[9]  
2
[10]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].