Finite time-Lyapunov based approach for robust adaptive control of wind-induced oscillations in power transmission lines

被引:11
|
作者
Ghabraei, Soheil [1 ]
Moradi, Hamed [1 ]
Vossoughi, Gholamreza [1 ]
机构
[1] Sharif Univ Technol, Dept Mech Engn, POB 11155-9567, Tehran, Iran
关键词
Transmission lines; Wind-induced oscillations; Parameter uncertainty; Robust adaptive control; Finite time control; DYNAMIC CHARACTERISTICS; VIBRATION SUPPRESSION; EXCITED VIBRATIONS; CABLES; CONDUCTORS; BEHAVIOR; MODEL; STABILIZATION; STABILITY; SYSTEM;
D O I
10.1016/j.jsv.2016.02.038
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Large amplitude oscillation of the power transmission lines, which is also known as galloping phenomenon, has hazardous consequences such as short circuiting and failure of transmission line. In this article, to suppress the undesirable vibrations of the transmission lines, first the governing equations of transmission line are derived via mode summation technique. Then, due to the occurrence of large amplitude vibrations, non-linear quadratic and cubic terms are included in the derived linear equations. To suppress the vibrations, arbitrary number of the piezoelectric actuators is assumed to exert the actuation forces. Afterwards, a Lyapunov based approach is proposed for the robust adaptive suppression of the undesirable vibrations in the finite time. To compensate the supposed parametric uncertainties with unknown bands, proper adaption laws are introduced. To avoid the vibration devastating consequences as quickly as possible, appropriate control laws are designed. The vibration suppression in the finite time with supposed adaption and control laws is mathematically proved via Lyapunov finite time stability theory. Finally, to illustrate and validate the efficiency and robustness of the proposed finite time control scheme, a parametric case study with three piezoelectric actuators is performed. It is observed that the proposed active control strategy is more efficient and robust than the passive control methods. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:19 / 34
页数:16
相关论文
共 50 条
  • [31] Development and Application of Eddy Current Damping-Based Tuned Mass Damper for Wind-Induced Vibration Control of Transmission Tower
    Lei, Xu
    Shen, Lian
    Niu, Huawei
    Chen, Jinlin
    Xie, Wenping
    Zhang, Xuewen
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2024, 24 (05)
  • [32] Robust Adaptive Fault-Tolerant Control for MAGLEV Train Systems: A Nonsingular Finite-Time Approach
    Najafi, Amin
    Mobayen, Saleh
    Rouhani, Seyed Hossein
    Mokhtare, Zahra
    Jalilvand, Abolfazl
    Fridman, Leonid
    Su, Chun-Lien
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2025, 11 (01): : 3680 - 3690
  • [34] Finite-Time Disturbance Observer-Based Adaptive Continuous Robust Control for Buck Converter
    Aghdam, Mohammadreza Hassanzadeh
    Mazare, Mahmood
    Torkaman, Hossein
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024,
  • [35] Model-free robust adaptive control of overhead cranes with finite-time convergence based on time-delay control
    Liu, Suqi
    Xu, Weimin
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2023, 45 (06) : 1037 - 1051
  • [36] Robust Finite Control-Set Model Predictive Control for Power Quality Enhancement of a Wind System Based on the DFIG Generator
    Alami, Houda El
    Bossoufi, Badre
    El Mahfoud, Mohammed
    Bouderbala, Manale
    Majout, Btissam
    Skruch, Pawel
    Mobayen, Saleh
    ENERGIES, 2023, 16 (03)
  • [37] Robust observer-based fuzzy control for variable speed wind power system: LMI approach
    Hwa Chang Sung
    Jin Bae Park
    Young Hoon Joo
    International Journal of Control, Automation and Systems, 2011, 9 : 1103 - 1110
  • [38] Robust Observer-based Fuzzy Control for Variable Speed Wind Power System: LMI Approach
    Sung, Hwa Chang
    Park, Jin Bae
    Joo, Young Hoon
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2011, 9 (06) : 1103 - 1110
  • [39] Input channel gain adaptive active disturbance rejection control based on robust adaptive finite-time parameter estimation
    Qiu, Shiyin
    Guo, Wei
    Liu, Yuan
    Li, Mantian
    IET CONTROL THEORY AND APPLICATIONS, 2024, 18 (03): : 306 - 315
  • [40] An Adaptive Droop Coefficient Based Voltage Control Approach for Wind Power Plants through Enhanced Reactive Power Support
    Shabbir, Md Nasmus Sakib Khan
    Liang, Xiaodong
    Chakrabarti, Saikat
    2022 IEEE/IAS 58TH INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE (I&CPS), 2022,