Cone-beam computed tomography of the head in standing equids

被引:15
|
作者
Bregger, M. D. Klopfenstein [1 ,2 ]
Koch, C. [1 ,2 ]
Zimmermann, R. [3 ]
Sangiorgio, D. [3 ]
Schweizer-Gorgas, D. [3 ]
机构
[1] Univ Bern, Vetsuisse Fac, Dept Clin Vet Med, Swiss Inst Equine Med ISME, Bern, Switzerland
[2] Agroscope, Bern, Switzerland
[3] Univ Bern, Vetsuisse Fac, Div Clin Radiol, Bern, Switzerland
关键词
Cone beam computed tomography; O-arm (R); Horse; Standing; Head;
D O I
10.1186/s12917-019-2045-z
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Computed tomography in standing horses has revolutionized diagnostic imaging. The O-arm (R), a cone beam computed tomography (CBCT) scanner with a gantry opening of 96.5 cm is routinely used for image-guided spine and neurosurgery in humans. The aim of this study is to describe the set-up and first experiences using the O-arm (R) to achieve CBCT imaging of the head in standing horses. CT imaging of the predefined region of interest (ROI) was tested on 2 cadaveric heads, concentrating on centering issues within the gantry, as well as determining the number of scans needed per ROI. All horses presented with head-related diseases and subjected to a CBCT examination between February 2015 and November 2016 for CBCT were included. Per scan, a limited field of view, i.e. a cylindrical volume of 21 cm in diameter and 16 cm in height was acquired within 13 s. Depending on the dimensions of the ROI, the minimum number of scans could range from one to six, if the entire equine head is to be examined in an adult horse. Results Sixty-eight horses were included, five of which had a follow-up CBCT exam, and two of which were presented twice for two different indications (75 clinical cases). A total number of 449 acquired three-dimensional (3D) scans were recorded for these 75 cases. Two-hundred and forty-two 3D scans (54%) were considered as diagnostic quality. The imaging procedure was generally well tolerated by the sedated, standing equid, and diagnostic studies were performed in 73 out of 75 cases (97.3%). Motion artefacts and inadequate centering of the ROI were the most common reasons for non-diagnostic quality images and repeat scans of the same ROI. Conclusions CBCT is a valuable imaging modality for the equine head. Advantages of the O-arm (R) compared to a conventional multi-slice helical CT for imaging of the head in standing equids include the rapid image acquisition, the gantry's mobility in all dimensions, and the free movability of the entire imaging unit. Disadvantages include the considerable sensitivity to motion artefact, increased scatter, low soft tissue contrast and the limited dimensions of the field of view.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Osteoporosis detection using cone-beam computed tomography
    Geibel, M-A.
    Loeffler, F.
    Kildal, D.
    ORTHOPADE, 2016, 45 (12): : 1066 - 1071
  • [32] Clinical guidelines for dental cone-beam computed tomography
    Takafumi Hayashi
    Yoshinori Arai
    Toru Chikui
    Sachiko Hayashi-Sakai
    Kazuya Honda
    Hiroko Indo
    Taisuke Kawai
    Kaoru Kobayashi
    Shumei Murakami
    Masako Nagasawa
    Munetaka Naitoh
    Eiji Nakayama
    Yutaka Nikkuni
    Hideyoshi Nishiyama
    Noriaki Shoji
    Shigeaki Suenaga
    Ray Tanaka
    Oral Radiology, 2018, 34 : 89 - 104
  • [33] Intraoperative Endodontic Applications of Cone-Beam Computed Tomography
    Ball, Randy L.
    Barbizam, Joao V.
    Cohenca, Nestor
    JOURNAL OF ENDODONTICS, 2013, 39 (04) : 548 - 557
  • [34] Cone-Beam Computed Tomography for Temporomandibular Joint Imaging
    Dhabale, Gunjan S.
    Bhowate, Rahul R.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [35] Stability of voxel values in cone-beam computed tomography
    Naitoh, Munetaka
    Aimiya, Hidetoshi
    Nakata, Kazuhiko
    Gotoh, Kenichi
    Ariji, Eiichiro
    ORAL RADIOLOGY, 2014, 30 (02) : 147 - 152
  • [36] Automatic landmark identification in cone-beam computed tomography
    Gillot, Maxime
    Miranda, Felicia
    Baquero, Baptiste
    Ruellas, Antonio
    Gurgel, Marcela
    Al Turkestani, Najla
    Anchling, Luc
    Hutin, Nathan
    Biggs, Elizabeth
    Yatabe, Marilia
    Paniagua, Beatriz
    Fillion-Robin, Jean-Christophe
    Allemang, David
    Bianchi, Jonas
    Cevidanes, Lucia
    Prieto, Juan Carlos
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2023, 26 (04) : 560 - 567
  • [37] Cone-beam micro computed tomography dedicated to the breast
    Sarno, Antonio
    Mettivier, Giovanni
    Di Lillo, Francesca
    Cesarelli, Mario
    Bifulco, Paolo
    Russo, Paolo
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (12) : 1449 - 1457
  • [38] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Erdem, Sule
    Zengin, Ayse Zeynep
    Erdem, Suheda
    SURGICAL AND RADIOLOGIC ANATOMY, 2020, 42 (11) : 1307 - 1313
  • [39] Motion compensation in extremity cone-beam computed tomography
    Alejandro Sisniega
    Gaurav K. Thawait
    Delaram Shakoor
    Jeffrey H. Siewerdsen
    Shadpour Demehri
    Wojciech Zbijewski
    Skeletal Radiology, 2019, 48 : 1999 - 2007
  • [40] Concrescence: Cone-Beam Computed Tomography Imaging Perspective
    Syed, Ali Zakir
    Alluri, LeelaSubhashini Choudary
    Mallela, Dhiraj
    Frazee, Troy
    CASE REPORTS IN DENTISTRY, 2016, 2016