Cone-beam computed tomography of the head in standing equids

被引:15
|
作者
Bregger, M. D. Klopfenstein [1 ,2 ]
Koch, C. [1 ,2 ]
Zimmermann, R. [3 ]
Sangiorgio, D. [3 ]
Schweizer-Gorgas, D. [3 ]
机构
[1] Univ Bern, Vetsuisse Fac, Dept Clin Vet Med, Swiss Inst Equine Med ISME, Bern, Switzerland
[2] Agroscope, Bern, Switzerland
[3] Univ Bern, Vetsuisse Fac, Div Clin Radiol, Bern, Switzerland
关键词
Cone beam computed tomography; O-arm (R); Horse; Standing; Head;
D O I
10.1186/s12917-019-2045-z
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Computed tomography in standing horses has revolutionized diagnostic imaging. The O-arm (R), a cone beam computed tomography (CBCT) scanner with a gantry opening of 96.5 cm is routinely used for image-guided spine and neurosurgery in humans. The aim of this study is to describe the set-up and first experiences using the O-arm (R) to achieve CBCT imaging of the head in standing horses. CT imaging of the predefined region of interest (ROI) was tested on 2 cadaveric heads, concentrating on centering issues within the gantry, as well as determining the number of scans needed per ROI. All horses presented with head-related diseases and subjected to a CBCT examination between February 2015 and November 2016 for CBCT were included. Per scan, a limited field of view, i.e. a cylindrical volume of 21 cm in diameter and 16 cm in height was acquired within 13 s. Depending on the dimensions of the ROI, the minimum number of scans could range from one to six, if the entire equine head is to be examined in an adult horse. Results Sixty-eight horses were included, five of which had a follow-up CBCT exam, and two of which were presented twice for two different indications (75 clinical cases). A total number of 449 acquired three-dimensional (3D) scans were recorded for these 75 cases. Two-hundred and forty-two 3D scans (54%) were considered as diagnostic quality. The imaging procedure was generally well tolerated by the sedated, standing equid, and diagnostic studies were performed in 73 out of 75 cases (97.3%). Motion artefacts and inadequate centering of the ROI were the most common reasons for non-diagnostic quality images and repeat scans of the same ROI. Conclusions CBCT is a valuable imaging modality for the equine head. Advantages of the O-arm (R) compared to a conventional multi-slice helical CT for imaging of the head in standing equids include the rapid image acquisition, the gantry's mobility in all dimensions, and the free movability of the entire imaging unit. Disadvantages include the considerable sensitivity to motion artefact, increased scatter, low soft tissue contrast and the limited dimensions of the field of view.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] The use of cone-beam computed tomography for orthodontic purposes
    Kuijpers-Jagtman, Anne Marie
    Kuijpers, Mette A. R.
    Schols, Jan G. J. H.
    Maal, Thomas J. J.
    Breuning, Karel H.
    van Vlijmen, Olivier J. C.
    SEMINARS IN ORTHODONTICS, 2013, 19 (03) : 196 - 203
  • [22] Stereotactic registration using cone-beam computed tomography
    Carlson, Jonathan Dennis
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 182 : 107 - 111
  • [23] Cone-beam Computed Tomography Image Pretreatment and Segmentation
    Zheng, Jia
    Zhang, Dinghua
    Huang, Kuidong
    Sun, Yuanxi
    2018 11TH INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DESIGN (ISCID), VOL 1, 2018, : 25 - 28
  • [24] Empirical water precorrection for cone-beam computed tomography
    Sourbelle, Katia
    Kachelriess, Marc
    Kalender, Willi A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1871 - 1875
  • [25] Trends in maxillofacial cone-beam computed tomography usage
    Arnheiter C.
    Scarfe W.C.
    Farman A.G.
    Oral Radiology, 2006, 22 (2) : 80 - 85
  • [26] Cone-Beam Computed Tomography in Endodontics—State of the Art
    Mazzi-Chaves J.F.
    Camargo R.V.
    Borges A.F.
    Silva R.G.
    Pauwels R.
    Silva-Sousa Y.T.C.
    Sousa-Neto M.D.
    Current Oral Health Reports, 2021, 8 (2) : 9 - 22
  • [27] Cone-beam computed tomography of the maxillofacial region - an update
    Kau, Chung How
    Bozic, Marko
    English, Jeryl
    Lee, Robert
    Bussa, Harry
    Ellis, Randy K.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (04): : 366 - 380
  • [28] Quality Control in Dental Cone-Beam Computed Tomography
    Huang, Jin-Feng
    Chen, Xiao-Zhao
    Wang, Hong
    APPLIED SCIENCES-BASEL, 2021, 11 (17):
  • [29] AUTOMATIC MOTION CORRECTION IN CONE-BEAM COMPUTED TOMOGRAPHY
    Ens, S.
    Ulrici, J.
    Hell, E.
    Buzug, T. M.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3248 - 3251
  • [30] Cone-beam computed tomography in the diagnosis of regional odontodysplasia
    Mabrouk, Rihab
    Chouchene, Farah
    Maatouk, Fethi
    Masmoudi, Fatma
    Baaziz, Ahlem
    Ghedira, Hichem
    CLINICAL CASE REPORTS, 2022, 10 (05):