摘要
OBJECTIVE. CT fluoroscopy-guided lumbar spine pain injections typically include a preprocedural planning CT that contributes considerably to patient dose. The purpose of this study was to quantify the degree of radiation exposure reduction achieved by modifying only the planning CT component of the examination. MATERIALS AND METHODS. A retrospective review was performed of 80 CT fluoroscopy-guided lumbar spine injections. Forty patients were scanned with a standard protocol using automatic tube current modulation (method A). Another 40 patients were scanned using a new technique that fixed the tube current of the planning CT to either 50 or 100 mA on the basis of the patient's anteroposterior diameter and that reduced the z-axis coverage (method B). Dose-length products (DLPs) were compared for the two methods. RESULTS. The mean maximal tube current for the planning CT was 435.0 mA for method A and 67.5 mA for method B. The mean z-axis was shorter for method B at 6.5 cm than for method A at 9.6 cm (p < 0.0001). The mean DLP for the planning CT was 11 times lower for method B than for method A: 27.9 versus 313.1 mGy x cm, respectively (p < 0.0001). When method B was used, the mean DLP for the total procedure (i.e., planning CT plus CT fluoroscopy components) was reduced by 78%. There was no significant difference between methods A and B in CT fluoroscopy time (p = 0.37). All procedures were technically successful. CONCLUSION. A nearly fivefold reduction in radiation exposure can be achieved in CT fluoroscopy-guided lumbar spine pain injections through modifications to the planning CT alone.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 25 条
[1]   Radiation Dose and Image Quality at High-Pitch CT Angiography of the Aorta: Intraindividual and Interindividual Comparisons With Conventional CT Angiography [J].
Apfaltrer, Paul ;
Hanna, E. Lexworth ;
Schoepf, U. Joseph ;
Spears, J. Reid ;
Schoenberg, Stefan O. ;
Fink, Christian ;
Vliegenthart, Rozemarijn .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) :1402-1409
[2]   Radiation dose reduction in CT-guided periradicular injections in lumbar spine: Feasibility of a new institutional protocol for improved patient safety [J].
Juraj Artner ;
Balkan Cakir ;
Sebastian Weckbach ;
Heiko Reichel ;
Friederike Lattig .
Patient Safety in Surgery, 6 (1)
[3]   Effective radiation dose reduction in computed tomography-guided spinal injections: a prospective, comparative study with technical considerations [J].
Artner, Juraj ;
Lattig, Friederike ;
Reichel, Heiko ;
Cakir, Balkan .
ORTHOPEDIC REVIEWS, 2012, 4 (02) :109-112
[4]   Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction [J].
Becce, Fabio ;
Ben Salah, Yosr ;
Verdun, Francis R. ;
Vande Berg, Bruno C. ;
Lecouvet, Frederic E. ;
Meuli, Reto ;
Omoumi, Patrick .
SKELETAL RADIOLOGY, 2013, 42 (07) :937-945
[5]   Radiation Dose for 345 CT-Guided Interlaminar Lumbar Epidural Steroid Injections [J].
Chang, A. L. ;
Schoenfeld, A. H. ;
Brook, A. L. ;
Miller, T. S. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) :1882-1886
[6]   Real-time CT fluoroscopy: Evolution of an interventional tool [J].
Daly, B ;
Templeton, PA .
RADIOLOGY, 1999, 211 (02) :309-315
[7]   CT-fluoroscopy: Tool or gimmick? [J].
Froelich, JJ ;
Wagner, HJ .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (05) :297-305
[8]   THE EFFECT OF MAS VARIATION UPON COMPUTED-TOMOGRAPHY IMAGE QUALITY AS EVALUATED BY INVIVO AND INVITRO STUDIES [J].
HAAGA, JR ;
MIRALDI, F ;
MACINTYRE, W ;
LIPUMA, JP ;
BRYAN, PJ ;
WIESEN, E .
RADIOLOGY, 1981, 138 (02) :449-454
[9]   Radiation Dose Exposure for Lumbar Spine Epidural Steroid Injections: A Comparison of Conventional Fluoroscopy Data and CT Fluoroscopy Techniques [J].
Hoang, Jenny K. ;
Yoshizumi, Terry T. ;
Toncheva, Greta ;
Gray, Linda ;
Gafton, Andreia R. ;
Huh, Billy K. ;
Eastwood, James D. ;
Lascola, Christopher D. ;
Hurwitz, Lynne M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (04) :778-782
[10]   Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They? [J].
Huda, Walter ;
Mettler, Fred A. .
RADIOLOGY, 2011, 258 (01) :236-242