THE EFFECT OF OBLIQUE ELECTRON BEAMS TO THE SURFACE DOSE UNDER THE BOLUS

被引:11
作者
Demir, Bayram
Okutan, Murat
Cakir, Aydin
Goksel, Evren
Bilge, Hatice
机构
[1] Istanbul Univ, Fac Sci, Dept Phys, Istanbul, Turkey
[2] Istanbul Univ, Inst Oncol, Dept Med Phys, Istanbul, Turkey
关键词
Electron beams; Oblique incidence; Surface dose; Bolus; HIGH-ENERGY PHOTON; RADIOCHROMIC FILM; IN-VIVO; SKIN; THERAPY; IRRADIATION; DOSIMETRY;
D O I
10.1016/j.meddos.2008.12.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study is to determine file effect of bolus to the surface (lose in oblique electron incidences. Irradiations with 4.5, 6, 7.5, 9, and 12-MeV electron beams were made for the incidence angles of 0 degrees, 15 degrees, 30 degrees, 45 degrees, 60 degrees, 75 degrees and using 3 different bolus setups: (1) unbolused (no bolus), (2) 5-mm bolus, and (3) 10-mm bolus. A set of EBT gafchromic film pieces placed oil the phantom surface was irradiated with a 400-cGy dose at D(max) for each setup. Whereas surface dose increased with increasing incidence degrees in the absence of 1 bolus. it was seen that there was a large surface dose decreasing in the presence of a bolus with increasing incidence angles. For 60 degrees incidence angle, the relative surface doses with unbolused setup were: 88.10%, 90.06%, 89.35%, 90.25%, and 97.10%; with 5-mm bolus: 66.45%, 81.20%, 99.78%, 124.43%, and 116.07%; and with 10-mm bolus: 22.65%, 45.20%, 55.20%, 65.82%, and 90.27% for 4.5, 6, 7.5, 9, and 12 MeV, respectively. The use of bolus in the treatment of highly oblique surfaces with low-energy electron beams significantly decreases the surface dose. (c) 2009 American Association of Medical Dosimetrists.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 25 条
[1]   Postmastectomy chest wall radiation with electron-beam therapy: Outcomes and complications at the University of Louisville [J].
Amin-Zimmerman, F ;
Paris, K ;
Minor, GI ;
Spanos, W .
CANCER JOURNAL, 2005, 11 (03) :204-208
[3]   In vivo EBT radiochromic film dosimetry of electron beam for Total Skin Electron Therapy (TSET) [J].
Bufacchi, A. ;
Carosi, A. ;
Adorante, N. ;
delle Canne, S. ;
Malatesta, T. ;
Capparella, R. ;
Fragomeni, R. ;
Bonanni, A. ;
Leone, M. ;
Marmiroli, L. ;
Begnozzi, L. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2007, 23 (02) :67-72
[4]   STUDY OF ELASTO-GEL PADS USED AS SURFACE BOLUS MATERIAL IN HIGH-ENERGY PHOTON AND ELECTRON THERAPY [J].
CHANG, F ;
CHANG, P ;
BENSON, K ;
SHARE, F .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01) :191-193
[5]   Multilayer Gafchromic film detectors for breast skin dose determination in vivo [J].
Cheung, T ;
Butson, MJ ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (02) :N31-N37
[6]   Accurate skin dose measurements using radiochromic film in clinical applications [J].
Devic, S ;
Seuntjens, J ;
Abdel-Rahman, W ;
Evans, M ;
Olivares, M ;
Podgorsak, EB ;
Vuong, T ;
Soares, CG .
MEDICAL PHYSICS, 2006, 33 (04) :1116-1124
[7]   Moldable tissue equivalent bolus for high-energy photon and electron therapy [J].
Dubois, D ;
Bice, W ;
Bradford, B ;
Schneid, T ;
Engelmeier, R .
MEDICAL PHYSICS, 1996, 23 (09) :1547-1549
[8]   THE PROBLEM OF OBLIQUELY INCIDENT BEAMS IN ELECTRON-BEAM TREATMENT PLANNING [J].
EKSTRAND, KE ;
DIXON, RL .
MEDICAL PHYSICS, 1982, 9 (02) :276-278
[9]   PARTIAL BOLUSSING TO IMPROVE THE DEPTH DOSES IN THE SURFACE REGION OF LOW-ENERGY ELECTRON-BEAMS [J].
GALBRAITH, DM ;
RAWLINSON, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (02) :313-317
[10]  
Gambino P, 2005, J HIGH ENERGY PHYS, DOI 10.1088/1126-6708/2005/09/010