Prediction of response to cardiac resynchronization therapy using simple electrocardiographic and echocardiographic tools

被引:45
|
作者
Bonakdar, Hamid Reza [1 ]
Jorat, Mohammad Vahid [1 ]
Fazelifar, Amir Farjam [1 ]
Alizadeh, Abolfath [1 ]
Givtaj, Nozar [2 ]
Sameie, Niloofar [3 ]
Sadeghpour, Anita [3 ]
Haghjoo, Majid [1 ]
机构
[1] Iran Univ Med Sci, Dept Pacemaker & Electrophysiol, Rajaie Cardiovasc Med & Res Ctr, Tehran 1996911151, Iran
[2] Iran Univ Med Sci, Dept Res Lab, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[3] Iran Univ Med Sci, Dept Echocardiog, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
来源
EUROPACE | 2009年 / 11卷 / 10期
关键词
Cardiac resynchronization therapy; Heart failure; Response; Electrocardiography; Echocardiography; VENTRICULAR CONDUCTION DELAY; CONGESTIVE-HEART-FAILURE; QRS DURATION; DILATED CARDIOMYOPATHY; POSITIVE RESPONSE; DYSSYNCHRONY; DEFIBRILLATOR; IMPROVEMENT; IMPACT;
D O I
10.1093/europace/eup258
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To predict response to cardiac resynchronization therapy (CRT) in patients with heart failure (HF) and intraventricular conduction delay. The study population consisted of 82 consecutive HF patients with standard CRT indications. Patients were classified as responders, if they were alive without cardiac decompensation and experienced >= 15% decrease in left ventricular end-systolic volume. Sixty-eight percent of the enrolled patients responded to CRT. When compared with non-responders, responders had a wider baseline QRS width (P = 0.001), more marked QRS shortening (delta QRS) immediately after CRT (P = 0.001), and a better improvement in aortic velocity time integral (VTI) 24 h after CRT (P = 0.02). Moreover, there was a trend towards a greater baseline intraventricular dyssynchrony in the responder group (P = 0.07). By multivariable logistic regression, the baseline QRS width (OR: 0.95, 95% CI: 0.90-0.97, P = 0.001), delta QRS (OR: 1.038, 95% CI: 1.012-1.064, P = 0.003), and acute aortic VTI (OR: 0.81, 95% CI: 0.68-0.96, P = 0.017) emerged as independent predictors of response to CRT. Receiver operating characteristic curve analysis identified a QRS width > 145 ms, delta QRS > 20 ms, and aortic VTI > 14 cm to predict responders. A positive response to CRT was observed in 68% of the patients. Cardiac resynchronization therapy response is predictable using simple electrocardiographic and echocardiographic data.
引用
收藏
页码:1330 / 1337
页数:8
相关论文
共 50 条
  • [31] Echocardiographic Patient Selection for Cardiac Resynchronization Therapy Betting on a Dead Horse?
    Breithardt, Ole A.
    JACC-CARDIOVASCULAR IMAGING, 2009, 2 (05) : 544 - 547
  • [32] Predictors of positive response to cardiac resynchronization therapy
    Rinkuniene, Diana
    Bucyte, Silvija
    Ceseviciute, Kristina
    Abramavicius, Silvijus
    Baronaite-Dudoniene, Kristina
    Laukaitiene, Jolanta
    Kazakevicius, Tomas
    Zabiela, Vytautas
    Sileikis, Vytautas
    Puodziukynas, Aras
    Jurkevicius, Renaldas
    BMC CARDIOVASCULAR DISORDERS, 2014, 14
  • [33] Echocardiography, dyssynchrony, and the response to cardiac resynchronization therapy
    Yu, Cheuk-Man
    Sanderson, John E.
    Gorcsan, John, III
    EUROPEAN HEART JOURNAL, 2010, 31 (19) : 2326 - +
  • [34] A systematic approach to designing reliable VV optimization methodology: Assessment of internal validity of echocardiographic, electrocardiographic and haemodynamic optimization of cardiac resynchronization therapy
    Kyriacou, Andreas
    Wa, Matthew E. Li Kam
    Pabari, Punam A.
    Unsworth, Beth
    Baruah, Resham
    Willson, Keith
    Peters, Nicholas S.
    Kanagaratnam, Prapa
    Hughes, Alun D.
    Mayet, Jamil
    Whinnett, Zachary I.
    Francis, Darrel P.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (03) : 954 - 964
  • [35] Influence of Pacing Site Characteristics on Response to Cardiac Resynchronization Therapy
    Wong, Jorge A.
    Yee, Raymond
    Stirrat, John
    Scholl, David
    Krahn, Andrew D.
    Gula, Lorne J.
    Skanes, Allan C.
    Leong-Sit, Peter
    Klein, George J.
    McCarty, David
    Fine, Nowell
    Goela, Aashish
    Islam, Ali
    Thompson, Terry
    Drangova, Maria
    White, James A.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (04) : 542 - 550
  • [36] The value of septal rebound stretch analysis for the prediction of volumetric response to cardiac resynchronization therapy
    Salden, Odette A. E.
    Zweerink, Alwin
    Wouters, Philippe
    Allaart, Cornelis P.
    Geelhoed, Bastiaan
    de Lange, Frederik J.
    Maass, Alexander H.
    Rienstra, Michiel
    Vernooy, Kevin
    Vos, Marc A.
    Meine, Mathias
    Prinzen, Frits W.
    Cramer, Maarten J.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2021, 22 (01) : 37 - 45
  • [37] Predictors of echocardiographic response to cardiac resynchronization therapy: A systematic review with Meta-Analysis
    Martins, Rodrigo
    Antonio, Natalia
    Donato, Helena
    Oliveiros, Barbara
    IJC HEART & VASCULATURE, 2022, 39
  • [38] S(e)ptal rebound stretch as predictor of echocardiographic response to cardiac resynchronization therapy
    Ghani, Abdul
    Delnoy, Peter Paul H. M.
    Adiyaman, Ahmet
    Ottervanger, Jan Paul
    Misier, Anand R. Ramdat
    Smit, Jaap Jan J.
    Elvan, Arif
    IJC HEART & VASCULATURE, 2015, 7 : 22 - 27
  • [39] Impact of clinical and echocardiographic response to cardiac resynchronization therapy on long-term survival
    Bertini, Matteo
    Hoke, Ulas
    van Bommel, Rutger J.
    Ng, Arnold C. T.
    Shanks, Miriam
    Nucifora, Gaetano
    Auger, Dominique
    Borleffs, C. Jan Willem
    van Rijnsoever, Eva P. M.
    van Erven, Lieselot
    Schalij, Martin J.
    Marsan, Nina Ajmone
    Bax, Jeroen J.
    Delgado, Victoria
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (08) : 774 - 781
  • [40] Electrocardiographic patterns and long-term clinical outcome in cardiac resynchronization therapy
    Kronborg, Mads B.
    Nielsen, Jens C.
    Mortensen, Peter T.
    EUROPACE, 2010, 12 (02): : 216 - 222