Evaluation of an electrical impedance tomography-based global inhomogeneity index for pulmonary ventilation distribution

被引:220
|
作者
Zhao, Zhanqi [1 ,2 ,3 ]
Moeller, Knut [3 ]
Steinmann, Daniel [2 ]
Frerichs, Inez [4 ]
Guttmann, Josef [2 ]
机构
[1] Anaesthesiol Univ Klin Freiburg, Sekt Expt Anaesthesiol, D-79106 Freiburg, Germany
[2] Univ Med Ctr, Dept Anesthesiol & Crit Care Med, Sect Expt Anesthesiol, Freiburg, Germany
[3] Furtwangen Univ, Dept Biomed Engn, Villingen Schwenningen, Germany
[4] Univ Med Ctr Schleswig Holstein, Dept Anesthesiol & Intens Care Med, Kiel, Germany
关键词
Inhomogeneity index; Electrical impedance tomography; Pulmonary ventilation distribution; Ventilation therapy; END-EXPIRATORY PRESSURE; TIDAL VOLUMES; LUNG-TISSUE; RECRUITMENT; AIR; DERECRUITMENT; CURVES; MODEL;
D O I
10.1007/s00134-009-1589-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To evaluate the plausibility, stability, and interindividual comparability of the global inhomogeneity index (GI) based on electrical impedance tomography (EIT). The lung area in an EIT image was identified by using the lung area estimation method, which mirrors the lung regions in the functional EIT image and subsequently subtracts the cardiac-related areas. The tidal EIT image, showing the difference in impedances between end-inspiration and end-expiration, was calculated and the variations in its pixel values within the predefined lung area were then used as an indicator of inhomogeneous ventilation (the GI index). Fifty patients were investigated including 40 patients tracheally intubated with double-lumen tubes (test group) and 10 patients under anesthesia without pulmonary disease (control group). Positive end-expiratory pressure (PEEP) of 5 mbar was applied in the test group during both two-lung ventilation (TLV) and subsequent one-lung ventilation (OLV). The patients of the control group were ventilated without PEEP. EIT data were recorded in both groups. A significantly lower GI value was found in the control group (0.40 +/- A 0.05, P = 0.025 vs. TLV 0.74 +/- A 0.47 and P < 0.002 vs. OLV 1.51 +/- A 1.45). A significant difference was also found in the test group between TLV and OLV (P < 0.002). If GI was calculated only in the ventilated lung area during OLV (0.71 +/- A 0.32), it did not significantly differ from the test group during TLV. The GI index quantifies the gas distribution in the lung with a single number and reveals good interpatient comparability.
引用
收藏
页码:1900 / 1906
页数:7
相关论文
共 50 条
  • [21] Protective ventilation using electrical impedance tomography
    Luepschen, H.
    Meier, T.
    Grossherr, M.
    Leibecke, T.
    Karsten, J.
    Leonhardt, S.
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (07) : S247 - S260
  • [22] Time-based pulmonary features from electrical impedance tomography demonstrate ventilation heterogeneity in chronic obstructive pulmonary disease
    Milne, Stephen
    Huvanandana, Jacqueline
    Nguyen, Chinh
    Duncan, Joseph M.
    Chapman, David G.
    Tonga, Katrina O.
    Zimmermann, Sabine C.
    Slattery, Alexander
    King, Gregory G.
    Thamrin, Cindy
    JOURNAL OF APPLIED PHYSIOLOGY, 2019, 127 (05) : 1441 - 1452
  • [23] Evaluation of lung ventilation distribution using electrical impedance tomography in standing sedated horses with capnoperitoneum
    Beazley, Shannon G.
    Focken, Alex
    Fernandez-Parra, Rocio
    Thomas, Keri L.
    Adler, Andy
    Duke-Novakovski, Tanya
    VETERINARY ANAESTHESIA AND ANALGESIA, 2022, 49 (04) : 382 - 389
  • [24] Design and analysis of a multifrequency electrical impedance tomography-based pressure sensor
    Ghorbani, Reza
    Nahvi, Manoochehr
    OPTICAL ENGINEERING, 2022, 61 (12)
  • [25] Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing
    Vogt, Barbara
    Pulletz, Sven
    Elke, Gunnar
    Zhao, Zhanqi
    Zabel, Peter
    Weiler, Norbert
    Frerichs, Inez
    JOURNAL OF APPLIED PHYSIOLOGY, 2012, 113 (07) : 1154 - 1161
  • [26] Electrical Impedance Tomography-Based Spatial Reconstruction of Admittivity in a Cylindrical Object
    Dusek, Jan
    Mikulka, Jan
    PROCEEDINGS OF THE 2020 19TH INTERNATIONAL CONFERENCE ON MECHATRONICS - MECHATRONIKA (ME), 2020, : 114 - 119
  • [27] Clinical implication of monitoring regional ventilation using electrical impedance tomography
    Shono, Atsuko
    Kotani, Toru
    JOURNAL OF INTENSIVE CARE, 2019, 7
  • [28] Distribution of ventilation in young and elderly adults determined by electrical impedance tomography
    Frerichs, I
    Braun, P
    Dudykevych, T
    Hahn, G
    Genée, D
    Hellige, G
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2004, 143 (01) : 63 - 75
  • [29] Distribution of Ventilation Measured by Electrical Impedance Tomography in Critically Ill Children
    Inany, Hussam S.
    Rettig, Jordan S.
    Smallwood, Craig D.
    Arnold, John H.
    Walsh, Brian K.
    RESPIRATORY CARE, 2020, 65 (05) : 590 - 595
  • [30] Monotonicity-based electrical impedance tomography for lung imaging
    Zhou, Liangdong
    Harrach, Bastian
    Seo, Jin Keun
    INVERSE PROBLEMS, 2018, 34 (04)