Evaluation of an electrical impedance tomography-based global inhomogeneity index for pulmonary ventilation distribution

被引:220
|
作者
Zhao, Zhanqi [1 ,2 ,3 ]
Moeller, Knut [3 ]
Steinmann, Daniel [2 ]
Frerichs, Inez [4 ]
Guttmann, Josef [2 ]
机构
[1] Anaesthesiol Univ Klin Freiburg, Sekt Expt Anaesthesiol, D-79106 Freiburg, Germany
[2] Univ Med Ctr, Dept Anesthesiol & Crit Care Med, Sect Expt Anesthesiol, Freiburg, Germany
[3] Furtwangen Univ, Dept Biomed Engn, Villingen Schwenningen, Germany
[4] Univ Med Ctr Schleswig Holstein, Dept Anesthesiol & Intens Care Med, Kiel, Germany
关键词
Inhomogeneity index; Electrical impedance tomography; Pulmonary ventilation distribution; Ventilation therapy; END-EXPIRATORY PRESSURE; TIDAL VOLUMES; LUNG-TISSUE; RECRUITMENT; AIR; DERECRUITMENT; CURVES; MODEL;
D O I
10.1007/s00134-009-1589-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To evaluate the plausibility, stability, and interindividual comparability of the global inhomogeneity index (GI) based on electrical impedance tomography (EIT). The lung area in an EIT image was identified by using the lung area estimation method, which mirrors the lung regions in the functional EIT image and subsequently subtracts the cardiac-related areas. The tidal EIT image, showing the difference in impedances between end-inspiration and end-expiration, was calculated and the variations in its pixel values within the predefined lung area were then used as an indicator of inhomogeneous ventilation (the GI index). Fifty patients were investigated including 40 patients tracheally intubated with double-lumen tubes (test group) and 10 patients under anesthesia without pulmonary disease (control group). Positive end-expiratory pressure (PEEP) of 5 mbar was applied in the test group during both two-lung ventilation (TLV) and subsequent one-lung ventilation (OLV). The patients of the control group were ventilated without PEEP. EIT data were recorded in both groups. A significantly lower GI value was found in the control group (0.40 +/- A 0.05, P = 0.025 vs. TLV 0.74 +/- A 0.47 and P < 0.002 vs. OLV 1.51 +/- A 1.45). A significant difference was also found in the test group between TLV and OLV (P < 0.002). If GI was calculated only in the ventilated lung area during OLV (0.71 +/- A 0.32), it did not significantly differ from the test group during TLV. The GI index quantifies the gas distribution in the lung with a single number and reveals good interpatient comparability.
引用
收藏
页码:1900 / 1906
页数:7
相关论文
共 50 条
  • [1] Evaluation of an electrical impedance tomography-based global inhomogeneity index for pulmonary ventilation distribution
    Zhanqi Zhao
    Knut Möller
    Daniel Steinmann
    Inéz Frerichs
    Josef Guttmann
    Intensive Care Medicine, 2009, 35 : 1900 - 1906
  • [2] Global and local inhomogeneity indices of lung ventilation based on electrical impedance tomography
    Zhao, Z.
    Moeller, K.
    Steinmann, D.
    Guttmann, J.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 256 - 259
  • [3] A simulation study on the ventilation inhomogeneity measured with Electrical Impedance Tomography
    Schullcke, B.
    Krueger-Ziolek, S.
    Gong, B.
    Moeller, K.
    IFAC PAPERSONLINE, 2017, 50 (01): : 8781 - 8785
  • [4] Electrical Impedance Tomography During Mechanical Ventilation
    Walsh, Brian K.
    Smallwood, Craig D.
    RESPIRATORY CARE, 2016, 61 (10) : 1417 - 1424
  • [5] Electrical Impedance Tomography-based Ventilation Patterns in Patients after Major Surgery
    Iwata, Hirofumi
    Yoshida, Takeshi
    Hoshino, Taiki
    Aiyama, Yuki
    Maezawa, Takashi
    Hashimoto, Haruka
    Koyama, Yukiko
    Yamada, Tomomi
    Fujino, Yuji
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209 (11) : 1328 - 1337
  • [6] Evaluation of lung ventilation distribution in chronic obstructive pulmonary disease patients using the global inhomogeneity index
    Trenk, F.
    Mendes, L.
    Carvalho, P.
    Paiva, R. P.
    Henriques, J.
    Maglaveras, N.
    Chouvarda, I.
    Tsara, V.
    Teixeira, C. A.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 5286 - 5289
  • [7] Lung regions identified with CT improve the value of global inhomogeneity index measured with electrical impedance tomography
    Yang, Lin
    Dai, Meng
    Moeller, Knut
    Frerichs, Inez
    Adler, Andy
    Fu, Feng
    Zhao, Zhanqi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (04) : 1209 - 1219
  • [8] A lung area estimation method for analysis of ventilation inhomogeneity based on electrical impedance tomography
    Zhao, Zhanqi
    Steinmann, Daniel
    Mueller-Zivkovic, Danijela
    Martin, Joerg
    Frerichs, Inez
    Guttmann, Josef
    Moeller, Knut
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (02) : 171 - 182
  • [9] Global tidal variations, regional distribution of ventilation, and the regional onset of filling determined by electrical impedance tomography: reproducibility
    Caruana, L. R.
    Barnett, A. G.
    Tronstad, O.
    Paratz, J. D.
    Chang, A. T.
    Fraser, J. F.
    ANAESTHESIA AND INTENSIVE CARE, 2017, 45 (02) : 235 - 243
  • [10] Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography
    Frerichs, I
    Hahn, G
    Golisch, W
    Kurpitz, M
    Burchardi, H
    Hellige, G
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1998, 42 (06) : 721 - 726