A Monte Carlo simulation study on coarse septa for scatter correction in 3-D PET

被引:13
|
作者
Hasegawa, T
Tanaka, E
Yamashita, T
Watanabe, M
Yamaya, T
Murayama, H
机构
[1] Kitasato Univ, Sagamihara, Kanagawa 2288555, Japan
[2] Natl Inst Nucl Sci, Div Med Phys, Inage Ku, Chiba, Japan
[3] Tokyo Inst Technol, Imaging Sci & Engn Lab, Yokohama, Kanagawa 227, Japan
[4] Hamamatsu Photon KK, Cent Res Lab, Hamakita, Japan
[5] Hamamatsu Photon KK, Tokyo Branch, Minato Ku, Hamakita, Japan
关键词
coarse septa; lead tungstate; Monte Carlo method; positron emission tomography (PET); scatter correction;
D O I
10.1109/TNS.2002.803782
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report the usefulness of coarse septa in positron emission tomography (PET) by Monte Carlo simulation. Coarse septa result in higher sensitivity than found with the two-dimensional mode with conventional full septa and lower scatter fraction than the three-dimensional mode without septa. We propose a new scatter correction method using coarse septa, where scatter components are estimated from coincidence data for those line-of-respouses that are intercepted by the coarse septa. This scatter correction potentially has the ability to cope with scatter from radioactivity outside the field of view. In addition, we show the feasibility of a lead tungstate (PWO) PET scanner with coarse septa.
引用
收藏
页码:2133 / 2138
页数:6
相关论文
共 50 条
  • [1] A Monte-Carlo simulation study on coarse septa for scatter correction in 3D PET
    Hasegawa, T
    Tanaka, E
    Yamashita, T
    Watanabe, M
    Yamaya, T
    Murayama, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2110 - 2114
  • [2] Investigation of accelerated monte carlo techniques for PET simulation and 3-D PET scatter correction
    Holdsworth, CH
    Levin, CS
    Farquhar, TH
    Dahlbom, M
    Hoffman, EJ
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1500 - 1504
  • [3] Performance analysis of an improved 3-D PET Monte Carlo simulation and scatter correction
    Holdsworth, CH
    Levin, CS
    Janecek, M
    Dahlbom, M
    Hoffman, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 83 - 89
  • [4] Scatter Correction with Combined Single-Scatter Simulation and Monte Carlo Simulation for 3D PET
    Ye, Jinghan
    Song, Xiyun
    Hu, Zhiqiang
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [5] Investigation of accelerated Monte Carlo techniques for PET simulation and 3D PET scatter correction
    Holdsworth, CH
    Levin, CS
    Farquhar, TH
    Dahlbom, M
    Hoffman, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 74 - 81
  • [6] SCATTER CORRECTION IN 3-D PET
    LERCHER, MJ
    WIENHARD, K
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) : 649 - 657
  • [7] Accelerated Monte Carlo Scatter Correction for 3D PET.
    Holdsworth, CH
    Levin, CS
    Dahlbom, M
    Farquhar, TH
    Hoffman, EJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 195P - 195P
  • [8] Scatter correction techniques in 3D PET: A Monte Carlo evaluation
    Castiglioni, I
    Cremonesi, O
    Gilardi, MC
    Bettinardi, V
    Rizzo, G
    Savi, A
    Bellotti, E
    Fazio, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2053 - 2058
  • [9] Evaluation of a Monte Carlo scatter correction in clinical 3D PET
    Holdsworth, CH
    Badawi, RD
    Santos, P
    Van den Abbeele, AD
    Hoffman, EJ
    El Fakhri, G
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2540 - 2544
  • [10] Scatter correction techniques in 3D PET: a Monte Carlo evaluation
    Castiglioni, I.
    Cremonesi, O.
    Gilardi, M.C.
    Bettinardi, V.
    Rizzo, G.
    Savi, A.
    Bellotti, E.
    Fazio, F.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 1 : 738 - 742