A state-of-the-art review on passive friction dampers and their applications

被引:150
作者
Jaisee, Sujit [1 ,2 ]
Yue, Feng [1 ,2 ]
Ooi, Yi Hao [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Civil Engn, Shanghai Key Lab Digital Maintenance Bldg & Infra, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, State Key Lab Ocean Engn, Shanghai 200240, Peoples R China
关键词
State-of-the-art; Review paper; Passive energy dissipation device; Friction damper; TO-COLUMN JOINTS; ENERGY-DISSIPATION; EXPERIMENTAL BEHAVIOR; HYSTERETIC BEHAVIOR; VIBRATION CONTROL; SEISMIC RESPONSE; STEEL FRAMES; DESIGN; PERFORMANCE; CONNECTIONS;
D O I
10.1016/j.engstruct.2021.112022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a state-of-the-art review on friction type passive energy dissipation devices. Friction dampers are highly preferred as an energy dissipation device, particularly for the seismic fortification of the engineering structures due to their simplicity, reliability, and maximum energy dissipation as a result of the generation of rectangular hysteretic loops. Additionally, their performance is not significantly influenced by the loading amplitude, frequency, and the number of cycles. Hence, with a better understanding of friction mechanism and behavior, numerous novel passive dry friction dampers have been invented and applied in the field of civil engineering since 1980. However, decades of studies over these dampers are highly scattered throughout the academic community. Hence, the availability of many valuable pieces of research is out of reach for further studies. Therefore, a holistic chronological detail of advancement (development and application) in the field of passive friction dampers has been presented systematically in this study. The major purpose of this paper is to present an integrated and holistic overview of passive friction damper for the ease of further studies and generate future research directions for researchers who will be working in this field.
引用
收藏
页数:22
相关论文
共 150 条
[11]  
Bonchev G., 2017, Ce/papers, V1, P3092, DOI [10.1002/cepa.361, DOI 10.1002/CEPA.361]
[12]   Experimental studies on cyclic performance of column base weak axis aligned asymmetric friction connection [J].
Borzouie, J. ;
MacRae, G. A. ;
Chase, J. G. ;
Rodgers, G. W. ;
Clifton, G. C. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 112 :252-262
[13]  
Bowden FP, 2001, FRICTION LUBRICATION, V1
[14]   Simulations of a Variable Friction Device for Multihazard Mitigation [J].
Cao, Liang ;
Laflamme, Simon ;
Taylor, Douglas ;
Ricles, James .
JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (12)
[15]   Experimental behaviour of innovative thermal spray coating materials for FREEDAM joints [J].
Cavallaro, G. Ferrante ;
Francavilla, A. ;
Latour, M. ;
Piluso, V. ;
Rizzano, G. .
COMPOSITES PART B-ENGINEERING, 2017, 115 :289-299
[16]   Standardised friction damper bolt assemblies time-related relaxation and installed tension variability [J].
Cavallaro, Giovanni Ferrante ;
Latour, Massimo ;
Francavilla, Antonella Bianca ;
Piluso, Vincenzo ;
Rizzano, Gianvittorio .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 141 :145-155
[17]  
Chanchi Golondrino J, VELOCITY EFFECTS BEH
[18]  
Chen W.-F., 2005, HDB STRUCTURAL ENG, VSecond
[19]  
Cherry S., 1993, Earthquake Spectra, V9, P447, DOI [10.1193/1.1585724, DOI 10.1193/1.1585724]
[20]   Development and modeling of a frictional wall damper and its applications in reinforced concrete frame structures\ [J].
Cho, CG ;
Kwon, M .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2004, 33 (07) :821-838