Projective filtering of time-aligned ECG beats for repolarization duration measurement

被引:11
作者
Kotas, M. [1 ]
机构
[1] Silesian Tech Univ, Inst Elect, PL-44100 Gliwice, Poland
关键词
principal component analysis; projective filtering; ECG processing; repolarization duration measurement;
D O I
10.1016/j.cmpb.2006.10.001
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Automatic measurement of ventricular repolarization duration is difficult and highly prone to errors. We propose to mitigate this problem by applying projective filtering to enhance the ECG signal prior to measurements. Our method performs time-alignment of ECG beats and then employs the rules of principal component analysis to the desired ECG reconstruction. As a result, significant noise reduction is obtained while distortions of the desired ECG components remain negligible. The proposed method is presented under white noise conditions; the influence on the precision of repolarization. duration measurement is then investigated. Finally, the method's influence on evaluation of repolarization duration variability when the analyzed signals are contaminated with real electromyographic noise is discussed. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 18 条
  • [1] QT variability and HRV interactions in ECG:: Quantification and reliability
    Almeida, Rute
    Gouveia, Sonia
    Rocha, Ana Paula
    Pueyo, Esther
    Martínez, Juan Pablo
    Laguna, Pablo
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (07) : 1317 - 1329
  • [2] QT interval analysis on ambulatory electrocardiogram recordings: a selective beat averaging approach
    Badilini, F
    Maison-Blanche, P
    Childers, R
    Coumel, P
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (01) : 71 - 79
  • [3] Effective and efficient compression algorithm for ECG signals with irregular periods
    Chou, Hsiao-Hsuan
    Chen, Ying-Jui
    Shiau, Yu-Chien
    Kuo, Te-Son
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (06) : 1198 - 1205
  • [4] QT interval measurement:: Q to TApex or Q to TEnd?
    Davey, PP
    [J]. JOURNAL OF INTERNAL MEDICINE, 1999, 246 (02) : 145 - 149
  • [5] QUANTITATIVE INVESTIGATION OF QRS DETECTION RULES USING THE MIT/BIH ARRHYTHMIA DATABASE
    HAMILTON, PS
    TOMPKINS, WJ
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (12) : 1157 - 1165
  • [6] Evaluation of an automatic threshold based detector of waveform limits in holter ECG with the QT database
    Jane, R
    Blasi, A
    Garcia, J
    Laguna, P
    [J]. COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 295 - 298
  • [7] Jollife I., 1986, Principal Component Analysis
  • [9] NEW ALGORITHM FOR QT INTERVAL-ANALYSIS IN 24-HOUR HOLTER ECG - PERFORMANCE AND APPLICATIONS
    LAGUNA, P
    THAKOR, NV
    CAMINAL, P
    JANE, R
    YOON, HR
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (01) : 67 - 73
  • [10] A database for evaluation of algorithms for measurement of QT and other waveform intervals in the ECG
    Laguna, P
    Mark, RG
    Goldberg, A
    Moody, GB
    [J]. COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 673 - 676